Literature DB >> 17867280

Use of the Bentall method for replacement of an aortic Starr-Edwards ball valve prosthesis implanted 32 years previously.

Daisuke Yotsumoto1, Yoshifumi Iguro, Takayuki Ueno, Kazuhisa Matsumoto, Ryuzo Sakata.   

Abstract

We report the case of a 54-year-old woman who, 32 years previously, had undergone replacement of the ascending aorta by the inclusion method with a Starr-Edwards ball valve prosthesis and recently underwent aortic root re-reconstruction by the Bentall method. Routine chest radiography revealed dilatation of the mediastinum, and computed tomography revealed an aneurysm of the ascending aorta. At reoperation, although the cloth covering the cage of the Starr-Edwards ball valve prosthesis appeared worn and some pannus formation was seen, the Starr-Edwards ball valve was functioning normally. The aortic root was replaced with a composite graft that consisted of a 23-mm St. Jude bileaflet prosthesis and a 24-mm Hemashield gold graft. The patient was discharged from the hospital in good condition 25 days after surgery.

Entities:  

Mesh:

Year:  2007        PMID: 17867280     DOI: 10.1007/s11748-007-0138-2

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  8 in total

1.  Mitral replacement: clinical experience with a ball-valve prosthesis.

Authors:  A STARR; M L EDWARDS
Journal:  Ann Surg       Date:  1961-10       Impact factor: 12.969

2.  Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.

Authors:  Keiichiro Tayama; Hidetoshi Akashi; Eiki Tayama; Shuji Fukunaga; Takemi Kawara; Ken-ichi Kosuga; Shigeaki Aoyagi
Journal:  Circ J       Date:  2004-05       Impact factor: 2.993

3.  Thirty-year results of Starr-Edwards prostheses in the aortic and mitral position.

Authors:  O L Gödje; T Fischlein; K Adelhard; G Nollert; W Klinner; B Reichart
Journal:  Ann Thorac Surg       Date:  1997-03       Impact factor: 4.330

4.  Reoperation for a Starr-Edwards aortic prosthetic valve 33 years after initial implantation.

Authors:  Takahiko Misumi; Mikihiko Kudo; Kiyoshi Koizumi; Hiroya Kumamaru
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-03

5.  Long-term results of the cloth-covered Starr-Edwards ball valve.

Authors:  Motomi Shiono; Yukiyasu Sezai; Akira Sezai; Mitsumasa Hata; Mitsuru Iida; Nanao Negishi
Journal:  Ann Thorac Surg       Date:  2005-07       Impact factor: 4.330

6.  Echocardiography can detect cloth cover tears in fully covered Starr-Edwards valves: a long-term clinical and echocardiographic study.

Authors:  Y Shapira; M S Feinberg; R Hirsch; M Nili; A Sagie; M S Fernberg
Journal:  Am Heart J       Date:  1997-10       Impact factor: 4.749

7.  Valve dysfunction of the cloth-covered Starr-Edwards ball valve.

Authors:  Motomi Shiono; Akira Sezai; Mitsumasa Hata; Mitsuru Iida; Nanao Negishi; Yukiyasu Sezai
Journal:  Circ J       Date:  2005-07       Impact factor: 2.993

8.  Forty-year survival with the Starr-Edwards heart valve prosthesis.

Authors:  Guangqiang Gao; YingXing Wu; Gary L Grunkemeier; Anthony P Furnary; Albert Starr
Journal:  J Heart Valve Dis       Date:  2004-01
  8 in total
  1 in total

1.  Ascending aortic aneurysm in a patient with an aortic Starr-Edwards ball valve prosthesis implanted 39 years previously.

Authors:  Kosaku Nishigawa; Toshinori Totsugawa; Hidenori Yoshitaka; Yoshimasa Tsushima; Masahiko Kuinose; Genta Chikazawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2010-03-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.