Literature DB >> 17851716

Optimising the use of computed radiography in pediatric chest imaging.

R Sanchez Jacob1, E Vano-Galvan, E Vano, N Gomez Ruiz, J M Fernandez Soto, D Martinez Barrio, C Prieto.   

Abstract

The objective of this study was to analyze image quality of chest examinations in pediatric patients using computed radiography (CR) obtained with a wide range of doses to suggest the appropriate parameters for optimal image quality. A sample of 240 chest images in four age ranges was randomly selected from the examinations performed during 2004. Images were obtained using a CR system and were evaluated independently by three radiologists. Each image was scored using criteria proposed by the European Guidelines on Quality Criteria in Pediatrics. Mean global scoring and scoring of individual criteria more sensitive to noise were used to evaluate image quality. Agfa dose level (DL) was in the range 1.20 to 2.85. It was found that there was not significant correlation (R < 0.5) between image quality and DL for any of the age ranges for either global score or for individual criteria more related to noise. The mean value of DL was in the ranges 1.9-2.1 for the four age bands. From this study, a DL value of 1.6 is proposed for pediatric CR chest imaging. This could yield a reduction of approximately a factor of 2.5 in mean patient entrance surface doses.

Entities:  

Mesh:

Year:  2007        PMID: 17851716      PMCID: PMC3043687          DOI: 10.1007/s10278-007-9071-2

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  14 in total

Review 1.  Correlation and simple linear regression.

Authors:  Kelly H Zou; Kemal Tuncali; Stuart G Silverman
Journal:  Radiology       Date:  2003-06       Impact factor: 11.105

2.  Managing patient dose in digital radiology. A report of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  2004

3.  The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria.

Authors:  B Lanhede; M Båth; S Kheddache; P Sund; L Björneld; M Widell; A Almén; J Besjakov; S Mattsson; A Tingberg; C Herrmann; W Panzer; M Zankl; L G Månsson
Journal:  Br J Radiol       Date:  2002-01       Impact factor: 3.039

4.  Relative speeds of Kodak computed radiography phosphors and screen-film systems.

Authors:  W Huda; L N Rill; A P Bruner
Journal:  Med Phys       Date:  1997-10       Impact factor: 4.071

5.  Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction.

Authors:  A P Hufton; S M Doyle; H M Carty
Journal:  Br J Radiol       Date:  1998-02       Impact factor: 3.039

6.  ICRP recommendations on 'Managing patient dose in digital radiology'.

Authors:  E Vano
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

7.  Management of pediatric radiation dose using Agfa computed radiography.

Authors:  R Schaetzing
Journal:  Pediatr Radiol       Date:  2004-10

8.  Dose evaluation for paediatric chest x-ray examinations in Brazil and Sudan: low doses and reliable examinations can be achieved in developing countries.

Authors:  K E M Mohamadain; L A R da Rosa; A C P Azevedo; M R N Guebel; M C B Boechat; F Habani
Journal:  Phys Med Biol       Date:  2004-03-21       Impact factor: 3.609

9.  Real-time measurement and audit of radiation dose to patients undergoing computed radiography.

Authors:  Eliseo Vano; Jose Miguel Fernandez; Jose Ignacio Ten; Eduardo Guibelalde; Luciano Gonzalez; Cesar S A Pedrosa
Journal:  Radiology       Date:  2002-10       Impact factor: 11.105

10.  Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index.

Authors:  Sinead E Peters; Patrick C Brennan
Journal:  Eur Radiol       Date:  2001-12-13       Impact factor: 5.315

View more
  3 in total

1.  Normalizing Heterogeneous Medical Imaging Data to Measure the Impact of Radiation Dose.

Authors:  Luís A Bastião Silva; Luís S Ribeiro; Milton Santos; Nuno Neves; Dulce Francisco; Carlos Costa; José Luis Oliveira
Journal:  J Digit Imaging       Date:  2015-12       Impact factor: 4.056

2.  Radiation dose optimisation for conventional imaging in infants and newborns using automatic dose management software: an application of the new 2013/59 EURATOM directive.

Authors:  L Alejo; E Corredoira; F Sánchez-Muñoz; C Huerga; Z Aza; R Plaza-Núñez; A Serrada; M Bret-Zurita; M Parrón; C Prieto-Areyano; G Garzón-Moll; R Madero; E Guibelalde
Journal:  Br J Radiol       Date:  2018-04-09       Impact factor: 3.039

Review 3.  Digital radiography exposure indices: A review.

Authors:  Ursula Mothiram; Patrick C Brennan; Sarah J Lewis; Bernadette Moran; John Robinson
Journal:  J Med Radiat Sci       Date:  2014-05-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.