Literature DB >> 18512944

Automated gain control ion funnel trap for orthogonal time-of-flight mass spectrometry.

Yehia M Ibrahim1, Mikhail E Belov, Andrei V Liyu, Richard D Smith.   

Abstract

Time-of-flight mass spectrometry (TOF MS) is increasingly used in proteomics research. Herein, we report on the development and characterization of a TOF MS instrument with improved sensitivity equipped with an electrodynamic ion funnel trap (IFT) that employs an automated gain control (AGC) capability. The IFT-TOF MS was coupled to a reversed-phase capillary liquid chromatography (RPLC) separation and evaluated in experiments with complex proteolytic digests. When applied to a global tryptic digest of Shewanella oneidensis proteins, an order-of-magnitude increase in sensitivity compared to that of the conventional continuous mode of operation was achieved due to efficient ion accumulation prior to TOF MS analysis. As a result of this sensitivity improvement and related improvement in mass measurement accuracy, the number of unique peptides identified in the AGC-IFT mode was 5-fold greater than that obtained in the continuous mode.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18512944      PMCID: PMC2692322          DOI: 10.1021/ac8003488

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  22 in total

Review 1.  Orthogonal acceleration time-of-flight mass spectrometry.

Authors:  M Guilhaus; D Selby; V Mlynski
Journal:  Mass Spectrom Rev       Date:  2000 Mar-Apr       Impact factor: 10.946

2.  Characterization of multipole storage assisted dissociation: implications for electrospray ionization mass spectrometry characterization of biomolecules.

Authors:  K A Sannes-Lowery; S A Hofstadler
Journal:  J Am Soc Mass Spectrom       Date:  2000-01       Impact factor: 3.109

3.  Quadrupole time-of-flight versus triple-quadrupole mass spectrometry for the determination of phosphopeptides by precursor ion scanning.

Authors:  H Steen; B Küster; M Mann
Journal:  J Mass Spectrom       Date:  2001-07       Impact factor: 1.982

4.  Radial stratification of ions as a function of mass to charge ratio in collisional cooling radio frequency multipoles used as ion guides or ion traps.

Authors:  A V Tolmachev; H R Udseth; R D Smith
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

Review 5.  Advances in proteomics data analysis and display using an accurate mass and time tag approach.

Authors:  Jennifer S D Zimmer; Matthew E Monroe; Wei-Jun Qian; Richard D Smith
Journal:  Mass Spectrom Rev       Date:  2006 May-Jun       Impact factor: 10.946

6.  Gridless Ion Acceleration Systems for Time-of-Flight Mass Spectrometry.

Authors:  L Schmidt; H Jungclas; H W Fritsch; P Köhl
Journal:  J Am Soc Mass Spectrom       Date:  1993-10       Impact factor: 3.109

7.  Peer Reviewed: Orthogonal-Injection TOFMS for Analyzing Biomolecules.

Authors:  I V Chernushevich; W Ens; K G Standing
Journal:  Anal Chem       Date:  1999-07       Impact factor: 6.986

8.  An electrospray-ionization mass spectrometer with new features.

Authors:  S K Chowdhury; V Katta; B T Chait
Journal:  Rapid Commun Mass Spectrom       Date:  1990-03       Impact factor: 2.419

9.  A new technique for decomposition of selected ions in molecule ion reactor coupled with ortho-time-of-flight mass spectrometry.

Authors:  A Dodonov; V Kozlovsky; A Loboda; V Raznikov; I Sulimenkov; A Tolmachev; A Kraft; H Wollnik
Journal:  Rapid Commun Mass Spectrom       Date:  1997       Impact factor: 2.419

10.  Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnel.

Authors:  Jason S Page; Bogdan Bogdanov; Andrey N Vilkov; David C Prior; Michael A Buschbach; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-02       Impact factor: 3.109

View more
  16 in total

1.  Constant-momentum acceleration time-of-flight mass spectrometry with energy focusing.

Authors:  Elise A Dennis; Steven J Ray; Alexander W Gundlach-Graham; Christie G Enke; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2013-10-01       Impact factor: 3.109

2.  Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations.

Authors:  Yehia M Ibrahim; Ahmed M Hamid; Jonathan T Cox; Sandilya V B Garimella; Richard D Smith
Journal:  Anal Chem       Date:  2017-01-19       Impact factor: 6.986

3.  Dual Polarity Ion Confinement and Mobility Separations.

Authors:  Isaac K Attah; Sandilya V B Garimella; Ian K Webb; Gabe Nagy; Randolph V Norheim; Colby E Schimelfenig; Yehia M Ibrahim; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2019-03-04       Impact factor: 3.109

4.  Ion Trapping, Storage, and Ejection in Structures for Lossless Ion Manipulations.

Authors:  Xinyu Zhang; Sandilya V B Garimella; Spencer A Prost; Ian K Webb; Tsung-Chi Chen; Keqi Tang; Aleksey V Tolmachev; Randolph V Norheim; Erin S Baker; Gordon A Anderson; Yehia M Ibrahim; Richard D Smith
Journal:  Anal Chem       Date:  2015-05-26       Impact factor: 6.986

5.  Simulation of electric potentials and ion motion in planar electrode structures for lossless ion manipulations (SLIM).

Authors:  Sandilya V B Garimella; Yehia M Ibrahim; Ian K Webb; Aleksey V Tolmachev; Xinyu Zhang; Spencer A Prost; Gordon A Anderson; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-26       Impact factor: 3.109

6.  Characterization of Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations.

Authors:  Ahmed M Hamid; Yehia M Ibrahim; Sandilya V B Garimella; Ian K Webb; Liulin Deng; Tsung-Chi Chen; Gordon A Anderson; Spencer A Prost; Randolph V Norheim; Aleksey V Tolmachev; Richard D Smith
Journal:  Anal Chem       Date:  2015-10-28       Impact factor: 6.986

7.  Characterization of an Ion Mobility-Multiplexed Collision Induced Dissociation-Tandem Time-of-Flight Mass Spectrometry Approach.

Authors:  Yehia M Ibrahim; David C Prior; Erin S Baker; Richard D Smith; Mikhail E Belov
Journal:  Int J Mass Spectrom       Date:  2010-06-01       Impact factor: 1.986

8.  Pulsed multiple reaction monitoring approach to enhancing sensitivity of a tandem quadrupole mass spectrometer.

Authors:  Mikhail E Belov; Satendra Prasad; David C Prior; William F Danielson; Karl Weitz; Yehia M Ibrahim; Richard D Smith
Journal:  Anal Chem       Date:  2011-02-23       Impact factor: 6.986

9.  Achieving High Resolution Ion Mobility Separations Using Traveling Waves in Compact Multiturn Structures for Lossless Ion Manipulations.

Authors:  Ahmed M Hamid; Sandilya V B Garimella; Yehia M Ibrahim; Liulin Deng; Xueyun Zheng; Ian K Webb; Gordon A Anderson; Spencer A Prost; Randolph V Norheim; Aleksey V Tolmachev; Erin S Baker; Richard D Smith
Journal:  Anal Chem       Date:  2016-08-12       Impact factor: 6.986

10.  Ion manipulations in structures for lossless ion manipulations (SLIM): computational evaluation of a 90° turn and a switch.

Authors:  Sandilya V B Garimella; Yehia M Ibrahim; Ian K Webb; Andreas B Ipsen; Tsung-Chi Chen; Aleksey V Tolmachev; Erin S Baker; Gordon A Anderson; Richard D Smith
Journal:  Analyst       Date:  2015-10-21       Impact factor: 4.616

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.