Literature DB >> 9364793

A new technique for decomposition of selected ions in molecule ion reactor coupled with ortho-time-of-flight mass spectrometry.

A Dodonov1, V Kozlovsky, A Loboda, V Raznikov, I Sulimenkov, A Tolmachev, A Kraft, H Wollnik.   

Abstract

A molecule ion reactor (MIR), i.e. a gas filled radio-frequency only quadrupole with a longitudinal electrical field (RFQLEF), is used as an atmospheric pressure ionization interface for an orthogonal time-of-flight mass spectrometer (O-TOFMS). A new phenomenon of selective ion 'heating' in a MIR near Mathieu's instability threshold was found and confirmed by computer simulation. The 'heating' in collisions with buffer gas molecules leads to ion decomposition. In the case of multicharged ions, fragments with an m/z value higher than that of the parent ion have a stable motion and can be analysed by an O-TOFMS. Fragmentation of bradykinin and beta-endorphin molecular ions having a selected charge state is demonstrated. The spectra show clear 'ladder' structure. The phenomenon may be used as an alternative to tandem mass spectrometry (MS/MS) for molecule structure analysis.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9364793     DOI: 10.1002/(SICI)1097-0231(19971015)11:15<1649::AID-RCM67>3.0.CO;2-T

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  14 in total

1.  Controlled ion fragmentation in a 2-D quadrupole ion trap for external ion accumulation in ESI FTICR mass spectrometry.

Authors:  M E Belov; M V Gorshkov; H R Udseth; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2001-12       Impact factor: 3.109

2.  Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration.

Authors:  Bruce E Wilcox; Christopher L Hendrickson; Alan G Marshall
Journal:  J Am Soc Mass Spectrom       Date:  2002-11       Impact factor: 3.109

3.  Collisional activation of ions in RF ion traps and ion guides: the effective ion temperature treatment.

Authors:  Aleksey V Tolmachev; Andrey N Vilkov; Bogdan Bogdanov; Ljiljana Pasa-Tolić; Christophe D Masselon; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2004-11       Impact factor: 3.109

4.  Incorporation of a flared inlet capillary tube on a fourier transform ion cyclotron resonance mass spectrometer.

Authors:  Si Wu; Kai Zhang; Nathan K Kaiser; James E Bruce; David C Prior; Gordon A Anderson
Journal:  J Am Soc Mass Spectrom       Date:  2006-04-17       Impact factor: 3.109

5.  Design considerations for high speed quantitative mass spectrometry with MALDI ionization.

Authors:  Jay J Corr; Peter Kovarik; Bradley B Schneider; Jan Hendrikse; Alexander Loboda; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-05       Impact factor: 3.109

6.  Novel ion mobility setup combined with collision cell and time-of-flight mass spectrometer.

Authors:  Alexander Loboda
Journal:  J Am Soc Mass Spectrom       Date:  2006-03-09       Impact factor: 3.109

7.  Ion funnel trap interface for orthogonal time-of-flight mass spectrometry.

Authors:  Yehia Ibrahim; Mikhail E Belov; Aleksey V Tolmachev; David C Prior; Richard D Smith
Journal:  Anal Chem       Date:  2007-09-13       Impact factor: 6.986

8.  Ion trap mass analysis at high pressure: a theoretical view.

Authors:  Wei Xu; Qingyu Song; Scott A Smith; William J Chappell; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2009-07-10       Impact factor: 3.109

9.  Automated gain control ion funnel trap for orthogonal time-of-flight mass spectrometry.

Authors:  Yehia M Ibrahim; Mikhail E Belov; Andrei V Liyu; Richard D Smith
Journal:  Anal Chem       Date:  2008-05-31       Impact factor: 6.986

10.  Alexander F. Dodonov: 1939-2005.

Authors:  Igor V Chernushevich; Alexander V Loboda; Viatcheslav A Kozlovski; Valeri V Raznikov; Vladislav V Zelenov
Journal:  J Am Soc Mass Spectrom       Date:  2006-01       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.