Literature DB >> 17846802

Consequences of patient position in the radiographic measurement of artificial disc replacement angles.

Victor Kosmopoulos1, John McManus, Constantin Schizas.   

Abstract

Accurate clinical measurement of spinal range of motion (ROM) is essential in the evaluation of artificial disc performance. The effect of patient placement with respect to the X-ray beam source is yet to be reported and may be an influencing factor in radiographic artificial disc angle measurements. This study aims to evaluate how radiographic patient placement influences artificial disc angle measurements. An anatomically accurate synthetic L4-L5 motion segment was instrumented with an artificial disc and two pins. The instrumented motion segment was mounted onto a frame allowing for independent rotation and elevation while holding the artificial disc angle and anatomical position between L4 and L5 fixed. Analyses included descriptive statistics, evaluation of uncertainty, intra- and inter-observer, and a 2-way analysis of variance (ANOVA). The mean angle measurement range at the various positions was 1.26 degrees for the pin, and 2.74 degrees for the artificial disc endplates. The centered patient position had the highest inter- and intra-observer reliability. ANOVA results showed elevation effects to be statistically significant (P = 0.021), and rotational effects to be extremely statistically significant (P < 0.0001) for the pin angles. In terms of the mean artificial disc angle, however, the ANOVA showed a highly statistically significant interaction term (P = 0.002). A significant difference was found in the angle measurements of a fixed artificial disc prosthesis based on a sample of patient radiographic placement positions. Since it is important to assess the success of an artificial disc replacement by evaluating the relatively small ROM present, it is crucial to aim at minimizing the error by placing the patient parallel to the plate with the beam centered not at the mid lumbar spine, but at the level of the arthroplasty, for both flexion and extension views.

Entities:  

Mesh:

Year:  2007        PMID: 17846802      PMCID: PMC2365534          DOI: 10.1007/s00586-007-0486-8

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  15 in total

1.  Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model.

Authors:  Bryan W Cunningham; Jeffrey D Gordon; Anton E Dmitriev; Nianbin Hu; Paul C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  2003-10-15       Impact factor: 3.468

2.  Reliability of motion measurements after total disc replacement: the spike and the fin method.

Authors:  Balkan Cakir; Marcus Richter; Wolfhart Puhl; René Schmidt
Journal:  Eur Spine J       Date:  2005-09-08       Impact factor: 3.134

3.  Measurement of total disc replacement radiographic range of motion: a comparison of two techniques.

Authors:  Moe R Lim; Federico P Girardi; Kai Zhang; Russel C Huang; Margaret G Peterson; Frank P Cammisa
Journal:  J Spinal Disord Tech       Date:  2005-06

4.  Measurement error of lumbar total disc replacement range of motion.

Authors:  Moe R Lim; Randall T Loder; Russel C Huang; Stephen Lyman; Kai Zhang; Andrew Sama; Elias C Papadopoulos; Kristin Warner; Federico P Girardi; Frank P Cammisa
Journal:  Spine (Phila Pa 1976)       Date:  2006-05-01       Impact factor: 3.468

Review 5.  Intraclass correlations: uses in assessing rater reliability.

Authors:  P E Shrout; J L Fleiss
Journal:  Psychol Bull       Date:  1979-03       Impact factor: 17.737

6.  Reliability of physiological, psychological and cognitive variables in chronic fatigue syndrome and the role of graded exercise.

Authors:  Karen E Wallman; Alan R Morton; Carmel Goodman; Robert Grove
Journal:  J Sports Sci Med       Date:  2005-12-01       Impact factor: 2.988

7.  Correlation between range of motion and outcome after lumbar total disc replacement: 8.6-year follow-up.

Authors:  Russel C Huang; Federico P Girardi; Frank P Cammisa; Moe R Lim; Patrick Tropiano; Thierry Marnay
Journal:  Spine (Phila Pa 1976)       Date:  2005-06-15       Impact factor: 3.468

8.  Measurement of thoracic and lumbar fracture kyphosis: evaluation of intraobserver, interobserver, and technique variability.

Authors:  T R Kuklo; D W Polly; B D Owens; S M Zeidman; A S Chang; W R Klemme
Journal:  Spine (Phila Pa 1976)       Date:  2001-01-01       Impact factor: 3.468

9.  A prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part II: evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes.

Authors:  Paul C McAfee; Bryan Cunningham; Gwen Holsapple; Karen Adams; Scott Blumenthal; Richard D Guyer; Anton Dmietriev; James H Maxwell; John J Regan; Jorge Isaza
Journal:  Spine (Phila Pa 1976)       Date:  2005-07-15       Impact factor: 3.468

10.  Range of motion and adjacent level degeneration after lumbar total disc replacement.

Authors:  Russel C Huang; Patrick Tropiano; Thierry Marnay; Federico P Girardi; Moe R Lim; Frank P Cammisa
Journal:  Spine J       Date:  2006 May-Jun       Impact factor: 4.166

View more
  4 in total

Review 1.  Design concepts in lumbar total disc arthroplasty.

Authors:  Fabio Galbusera; Chiara M Bellini; Thomas Zweig; Stephen Ferguson; Manuela T Raimondi; Claudio Lamartina; Marco Brayda-Bruno; Maurizio Fornari
Journal:  Eur Spine J       Date:  2008-10-23       Impact factor: 3.134

2.  Radiographic total disc replacement angle measurement accuracy using the Oxford Cobbometer: precision and bias.

Authors:  Victor Kosmopoulos; Kosmas Stafylas; John McManus; Constantin Schizas
Journal:  Eur Spine J       Date:  2008-05-22       Impact factor: 3.134

3.  Does radiographic beam angle affect the radiocapitellar ratio measurement of subluxation in the elbow?

Authors:  Fannie McCann; Fanny Canet; Emilie Sandman; Yvan Petit; Dominique M Rouleau
Journal:  Clin Orthop Relat Res       Date:  2013-05-08       Impact factor: 4.176

4.  The parallax effect in the evaluation of range of motion in lumbar total disc replacement.

Authors:  Joshua D Auerbach; Surena Namdari; Andrew H Milby; Andrew P White; Sudheer C Reddy; Baron S Lonner; Richard A Balderston
Journal:  SAS J       Date:  2008-12-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.