Literature DB >> 17826321

Comparison of gated N-13 ammonia PET and gated Tc-99m sestamibi SPECT for quantitative analysis of global and regional left ventricular function.

Sugako Kanayama1, Ichiro Matsunari, Koji Kajinami.   

Abstract

BACKGROUND: The aim of this study was to compare global and regional left ventricular function in patients with coronary artery disease (CAD), obtained by use of Cedars-Sinai quantitative gated single photon emission computed tomography (QGS), for gated nitrogen 13 ammonia (NH(3)) positron emission tomography (PET) and technetium 99m sestamibi (MIBI) single photon emission computed tomography (SPECT). METHODS AND
RESULTS: Fifty-one patients with CAD underwent gated N-13 NH(3) PET and gated MIBI SPECT. The end-diastolic volume, end-systolic volume, and ejection fraction were calculated by use of QGS. The quantitative regional wall motion (WM) and wall thickening (WT) scores for 20 segments in the myocardium were also measured by QGS. The end-diastolic volume, end-systolic volume, and ejection fraction measured by N-13 NH(3) PET showed highly significant correlation with those measured by MIBI SPECT (r = 0.97, r = 0.97, and r = 0.84, respectively). The mean correlation of WM and WT on an individual patient basis between N-13 NH(3) PET and MIBI SPECT was 0.81 and 0.84, respectively. The circumferential variation of WM and WT in 20 segments showed a similar pattern with N-13 NH(3) PET and MIBI SPECT.
CONCLUSION: Gated N-13 NH(3) PET combined with QGS provides information on both global and regional left ventricular function comparable to that obtained by gated Tc-99m perfusion myocardial SPECT in CAD patients.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17826321     DOI: 10.1016/j.nuclcard.2007.05.011

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  30 in total

1.  Prolonged impairment of regional contractile function after resolution of exercise-induced angina. Evidence of myocardial stunning in patients with coronary artery disease.

Authors:  G Ambrosio; S Betocchi; L Pace; M A Losi; P Perrone-Filardi; A Soricelli; F Piscione; J Taube; F Squame; M Salvatore; J L Weiss; M Chiariello
Journal:  Circulation       Date:  1996-11-15       Impact factor: 29.690

2.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

3.  Performance characteristics of a whole-body PET scanner.

Authors:  T R DeGrado; T G Turkington; J J Williams; C W Stearns; J M Hoffman; R E Coleman
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

4.  Gated cardiac 13N-NH3 PET for assessment of left ventricular volumes, mass, and ejection fraction: comparison with electrocardiography-gated 18F-FDG PET.

Authors:  Aliasghar Khorsand; Senta Graf; Harald Eidherr; Wolfgang Wadsak; Kurt Kletter; Heinz Sochor; Ernst Schuster; Gerold Porenta
Journal:  J Nucl Med       Date:  2005-12       Impact factor: 10.057

5.  Inter-institution preference-based variability of ejection fraction and volumes using quantitative gated SPECT with 99mTc-tetrofosmin: a multicentre study involving 106 hospitals.

Authors:  Kenichi Nakajima; Tsunehiko Nishimura
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-09-29       Impact factor: 9.236

6.  Validation of an evaluation routine for left ventricular volumes, ejection fraction and wall motion from gated cardiac FDG PET: a comparison with cardiac magnetic resonance imaging.

Authors:  Wolfgang M Schaefer; Claudia S A Lipke; Bernd Nowak; Hans Juergen Kaiser; Arno Buecker; Gabriele A Krombach; Udalrich Buell; Harald P Kühl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-02-15       Impact factor: 9.236

7.  Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction.

Authors:  H D White; R M Norris; M A Brown; P W Brandt; R M Whitlock; C J Wild
Journal:  Circulation       Date:  1987-07       Impact factor: 29.690

8.  Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI.

Authors:  Wolfgang M Schaefer; Claudia S A Lipke; Bernd Nowak; Hans-Juergen Kaiser; Patrick Reinartz; Arno Buecker; Gabriele A Krombach; Udalrich Buell; Harald P Kühl
Journal:  J Nucl Med       Date:  2004-01       Impact factor: 10.057

9.  Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study.

Authors:  D S Berman; H Kiat; J D Friedman; F P Wang; K van Train; L Matzer; J Maddahi; G Germano
Journal:  J Am Coll Cardiol       Date:  1993-11-01       Impact factor: 24.094

10.  A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET.

Authors:  Y Choi; S C Huang; R A Hawkins; W G Kuhle; M Dahlbom; C K Hoh; J Czernin; M E Phelps; H R Schelbert
Journal:  J Nucl Med       Date:  1993-03       Impact factor: 10.057

View more
  5 in total

Review 1.  Facts and figures on CAD assessment with SPECT and PET-CT.

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-02       Impact factor: 9.236

2.  Gated myocardial perfusion imaging for the assessment of left ventricular function and volume: from SPECT to PET.

Authors:  Tali Sharir
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

3.  The impacts of severe perfusion defects, akinetic/dyskinetic segments, and viable myocardium on the accuracy of volumes and LVEF measured by gated ⁹⁹mTc-MIBI SPECT and gated ¹⁸F-FDG PET in patients with left ventricular aneurysm: cardiac magnetic resonance imaging as the reference.

Authors:  Hongxing Wei; Congna Tian; Thomas H Schindler; Mei Qiu; Minjie Lu; Rui Shen; Yueqin Tian; Shi-hua Zhao; Xiaoli Zhang
Journal:  J Nucl Cardiol       Date:  2014-09-05       Impact factor: 5.952

Review 4.  Cardiac PET perfusion: prognosis, risk stratification, and clinical management.

Authors:  Sharmila Dorbala; Marcelo F Di Carli
Journal:  Semin Nucl Med       Date:  2014-09       Impact factor: 4.446

Review 5.  Single photon emission computed tomography: an alternative imaging modality in left ventricular evaluation.

Authors:  Hulya Yalçin; Sofiane Maza; Fatih Yalçin
Journal:  Vasc Health Risk Manag       Date:  2008
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.