Literature DB >> 28958876

Modification of population based arterial input function to incorporate individual variation.

Harrison Kim1.   

Abstract

This technical note describes how to modify a population-based arterial input function to incorporate variation among the individuals. In DCE-MRI, an arterial input function (AIF) is often distorted by pulsated inflow effect and noise. A population-based AIF (pAIF) has high signal-to-noise ratio (SNR), but cannot incorporate the individual variation. AIF variation is mainly induced by variation in cardiac output and blood volume of the individuals, which can be detected by the full width at half maximum (FWHM) during the first passage and the amplitude of AIF, respectively. Thus pAIF scaled in time and amplitude fitting to the individual AIF may serve as a high SNR AIF incorporating the individual variation. The proposed method was validated using DCE-MRI images of 18 prostate cancer patients. Root mean square error (RMSE) of pAIF from individual AIFs was 0.88±0.48mM (mean±SD), but it was reduced to 0.25±0.11mM after pAIF modification using the proposed method (p<0.0001).
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Arterial input function; DCE-MRI

Mesh:

Substances:

Year:  2017        PMID: 28958876      PMCID: PMC5709187          DOI: 10.1016/j.mri.2017.09.010

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  37 in total

1.  Evidence for shutter-speed variation in CR bolus-tracking studies of human pathology.

Authors:  Thomas E Yankeelov; William D Rooney; Wei Huang; Jonathan P Dyke; Xin Li; Alina Tudorica; Jing-Huei Lee; Jason A Koutcher; Charles S Springer
Journal:  NMR Biomed       Date:  2005-05       Impact factor: 4.044

2.  Saturated double-angle method for rapid B1+ mapping.

Authors:  Charles H Cunningham; John M Pauly; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

3.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

Review 4.  The dielectric properties of biological tissues: I. Literature survey.

Authors:  C Gabriel; S Gabriel; E Corthout
Journal:  Phys Med Biol       Date:  1996-11       Impact factor: 3.609

Review 5.  Modeling tracer kinetics in dynamic Gd-DTPA MR imaging.

Authors:  P S Tofts
Journal:  J Magn Reson Imaging       Date:  1997 Jan-Feb       Impact factor: 4.813

6.  A comparison of two methods for estimating DCE-MRI parameters via individual and cohort based AIFs in prostate cancer: a step towards practical implementation.

Authors:  Andriy Fedorov; Jacob Fluckiger; Gregory D Ayers; Xia Li; Sandeep N Gupta; Clare Tempany; Robert Mulkern; Thomas E Yankeelov; Fiona M Fennessy
Journal:  Magn Reson Imaging       Date:  2014-01-21       Impact factor: 2.546

7.  T₁ mapping using variable flip angle SPGR data with flip angle correction.

Authors:  Gilad Liberman; Yoram Louzoun; Dafna Ben Bashat
Journal:  J Magn Reson Imaging       Date:  2013-11-25       Impact factor: 4.813

8.  Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects.

Authors:  J Logan; J S Fowler; N D Volkow; A P Wolf; S L Dewey; D J Schlyer; R R MacGregor; R Hitzemann; B Bendriem; S J Gatley
Journal:  J Cereb Blood Flow Metab       Date:  1990-09       Impact factor: 6.200

9.  Dynamic Contrast-Enhanced MRI in Low-Grade Versus Anaplastic Oligodendrogliomas.

Authors:  Julio Arevalo-Perez; Amanuel A Kebede; Kyung K Peck; Eli Diamond; Andrei I Holodny; Marc Rosenblum; Jennifer Rubel; Joshua Gaal; Vaios Hatzoglou
Journal:  J Neuroimaging       Date:  2015-12-26       Impact factor: 2.486

10.  Variation of the relaxographic "shutter-speed" for transcytolemmal water exchange affects the CR bolus-tracking curve shape.

Authors:  Thomas E Yankeelov; William D Rooney; Xin Li; Charles S Springer
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

View more
  6 in total

1.  Variability in Quantitative DCE-MRI: Sources and Solutions.

Authors:  Harrison Kim
Journal:  J Nat Sci       Date:  2018

Review 2.  Quantitative renal magnetic resonance imaging: magnetic resonance urography.

Authors:  J Damien Grattan-Smith; Jeanne Chow; Sila Kurugol; Richard Alan Jones
Journal:  Pediatr Radiol       Date:  2022-01-13

3.  Disposable point-of-care portable perfusion phantom for quantitative DCE-MRI.

Authors:  Martin D Holland; Andres Morales; Sean Simmons; Brandon Smith; Samuel R Misko; Xiaoyu Jiang; David A Hormuth; Chase Christenson; Roy P Koomullil; Desiree E Morgan; Yufeng Li; Junzhong Xu; Thomas E Yankeelov; Harrison Kim
Journal:  Med Phys       Date:  2021-12-10       Impact factor: 4.506

4.  Effects of artery input function on dynamic contrast-enhanced MRI for determining grades of gliomas.

Authors:  Lin Jia; Xia Wu; Qian Wan; Liwen Wan; Wenxiao Jia; Na Zhang
Journal:  Br J Radiol       Date:  2020-12-17       Impact factor: 3.039

5.  Accurate Therapeutic Response Assessment of Pancreatic Ductal Adenocarcinoma Using Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging With a Point-of-Care Perfusion Phantom: A Pilot Study.

Authors:  Harrison Kim; Desiree E Morgan; Patrick Schexnailder; Rudolph M Navari; Grant R Williams; J Bart Rose; Yufeng Li; Ravikumar Paluri
Journal:  Invest Radiol       Date:  2019-01       Impact factor: 6.016

6.  Portable Perfusion Phantom Offers Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Accurate Prostate Cancer Grade Stratification: A Pilot Study.

Authors:  Harrison Kim; John V Thomas; Jeffrey W Nix; Jennifer B Gordetsky; Yufeng Li; Soroush Rais-Bahrami
Journal:  Acad Radiol       Date:  2020-03-27       Impact factor: 3.173

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.