Literature DB >> 17763351

Comparison of airway diameter measurements from an anthropomorphic airway tree phantom using hyperpolarized 3He MRI and high-resolution computed tomography.

Yang-Sheng Tzeng1, Eric Hoffman, Janice Cook-Granroth, Rie Maurer, Niral Shah, Joey Mansour, Juerg Tschirren, Mitchell Albert.   

Abstract

An anthropomorphic airway tree phantom was imaged with both hyperpolarized (HP) 3He MRI using a dynamic projection scan and computed tomography (CT). Airway diameter measurements from the HP 3He MR images obtained using a newly developed model-based algorithm were compared against their corresponding CT values quantified with a well-established method. Of the 45 airway segments that could be evaluated with CT, only 14 airway segments (31%) could be evaluated using HP 3He MRI. No airway segments smaller than approximately 4 mm in diameter and distal to the fourth generation were adequate for analysis in MRI. For the 14 airway segments measured, only two airway segments yielded a non-equivalent comparison between the two imaging modalities, while eight more had inconclusive comparison results, leaving only four airway segments (29%) that satisfied the designed equivalence criteria. Some of the potential problems in airway diameter quantification described in the formulation of the model-based algorithm were observed in this study. These results suggest that dynamic projection HP 3He MRI may have limited utility for measuring airway segment diameters, particularly those of the central airways. Copyright (c) 2007 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2007        PMID: 17763351      PMCID: PMC2943874          DOI: 10.1002/mrm.21285

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  29 in total

1.  Dynamic echo planar MR imaging of lung ventilation with hyperpolarized (3)He in normal subjects and patients with severe emphysema.

Authors:  D S Gierada; B Saam; D Yablonskiy; J D Cooper; S S Lefrak; M S Conradi
Journal:  NMR Biomed       Date:  2000-06       Impact factor: 4.044

2.  Dynamic imaging of hyperpolarized (3)He distribution in rat lungs using interleaved-spiral scans.

Authors:  M Viallon; Y Berthezène; V Callot; M Bourgeois; H Humblot; A Briguet; Y Crémillieux
Journal:  NMR Biomed       Date:  2000-06       Impact factor: 4.044

3.  Hyperpolarized 3He MR lung ventilation imaging in asthmatics: preliminary findings.

Authors:  T A Altes; P L Powers; J Knight-Scott; G Rakes; T A Platts-Mills; E E de Lange; B A Alford; J P Mugler; J R Brookeman
Journal:  J Magn Reson Imaging       Date:  2001-03       Impact factor: 4.813

4.  Laser-polarized (3)He as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging.

Authors:  M Viallon; Y Berthezène; M Décorps; M Wiart; V Callot; M Bourgeois; H Humblot; A Briguet; Y Crémillieux
Journal:  Magn Reson Med       Date:  2000-07       Impact factor: 4.668

5.  Dynamic spiral MRI of pulmonary gas flow using hyperpolarized (3)He: preliminary studies in healthy and diseased lungs.

Authors:  M Salerno; T A Altes; J R Brookeman; E E de Lange; J P Mugler
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

6.  Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI.

Authors:  Ben T Chen; Anja C S Brau; G Allan Johnson
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

7.  An analysis algorithm for measuring airway lumen and wall areas from high-resolution computed tomographic data.

Authors:  G G King; N L Müller; K P Whittall; Q S Xiang; P D Paré
Journal:  Am J Respir Crit Care Med       Date:  2000-02       Impact factor: 21.405

8.  High resolution computed tomographic assessment of airway wall thickness in chronic asthma: reproducibility and relationship with lung function and severity.

Authors:  S A Little; M W Sproule; M D Cowan; K J Macleod; M Robertson; J G Love; G W Chalmers; C P McSharry; N C Thomson
Journal:  Thorax       Date:  2002-03       Impact factor: 9.139

9.  (3)He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes.

Authors:  D Guenther; B Eberle; J Hast; J Lill; K Markstaller; M Puderbach; W G Schreiber; G Hanisch; C P Heussel; R Surkau; T Grossmann; N Weiler; M Thelen; H U Kauczor
Journal:  NMR Biomed       Date:  2000-06       Impact factor: 4.044

10.  Airway narrowing in healthy humans inhaling methacholine without deep inspirations demonstrated by HRCT.

Authors:  R H Brown; P Croisille; B Mudge; F B Diemer; S Permutt; A Togias
Journal:  Am J Respir Crit Care Med       Date:  2000-04       Impact factor: 21.405

View more
  6 in total

Review 1.  Imaging of lung function using hyperpolarized helium-3 magnetic resonance imaging: Review of current and emerging translational methods and applications.

Authors:  Sean Fain; Mark L Schiebler; David G McCormack; Grace Parraga
Journal:  J Magn Reson Imaging       Date:  2010-12       Impact factor: 4.813

2.  Three-dimensional imaging of ventilation dynamics in asthmatics using multiecho projection acquisition with constrained reconstruction.

Authors:  James H Holmes; Rafael L O'Halloran; Ethan K Brodsky; Thorsten A Bley; Christopher J Francois; Julia V Velikina; Ronald L Sorkness; William W Busse; Sean B Fain
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

3.  Investigation of hyperpolarized 3He magnetic resonance imaging utility in examining human airway diameter behavior in asthma through comparison with high-resolution computed tomography.

Authors:  Yang-Sheng Tzeng; Eric Hoffman; Janice Cook-Granroth; Jessica Gereige; Joey Mansour; George Washko; Michael Cho; Evan Stepp; Kenneth Lutchen; Mitchell Albert
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

4.  Long-Range Optical Coherence Tomography of the Neonatal Upper Airway for Early Diagnosis of Intubation-related Subglottic Injury.

Authors:  Giriraj K Sharma; Gurpreet S Ahuja; Maximilian Wiedmann; Kathryn E Osann; Erica Su; Andrew E Heidari; Joseph C Jing; Yueqiao Qu; Frances Lazarow; Alex Wang; Lidek Chou; Cherry C Uy; Vijay Dhar; John P Cleary; Nguyen Pham; Kevin Huoh; Zhongping Chen; Brian J-F Wong
Journal:  Am J Respir Crit Care Med       Date:  2015-12-15       Impact factor: 21.405

5.  The comparison of the lengths and diameters of main bronchi measured from two-dimensional and three-dimensional images in the same patients.

Authors:  Jeong Woo Lee; Ji-Seon Son; Jin-Wook Choi; Young-Jin Han; Jun-Rae Lee
Journal:  Korean J Anesthesiol       Date:  2014-03-28

6.  High-quality chest CT segmentation to assess the impact of COVID-19 disease.

Authors:  Michele Bertolini; Alma Brambilla; Samanta Dallasta; Giorgio Colombo
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-08-06       Impact factor: 2.924

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.