Literature DB >> 10867694

(3)He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes.

D Guenther1, B Eberle, J Hast, J Lill, K Markstaller, M Puderbach, W G Schreiber, G Hanisch, C P Heussel, R Surkau, T Grossmann, N Weiler, M Thelen, H U Kauczor.   

Abstract

MRI with hyperpolarized helium-3 ((3)He) provides high-resolution imaging of ventilated airspaces. The first aim of this (3)He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired (3)He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/alpha = 11 ms/4.2 ms/<10 degrees ). Known amounts of (3)He were inhaled from a microprocessor-controlled delivery device and imaged during single breath-holds. Images were evaluated visually, and scored using a prospectively defined 'defect-index'. Signal-to-noise ratio of the images were correlated with localization, (3)He volumes and static lung volumes. Due to poor image quality studies of two smokers were not eligible for the evaluation. Smokers differed from non-smokers in total number and size of defects: the 'defect-index' of smokers ranged between 0.8 and 6.0 (median = 1.1), that of non-smokers between 0.1 and 0.8 (median = 0.4). Intraindividually, an anteroposterior gradient of signal-to-noise ratio was apparent. Signal-to-noise ratio correlated with the estimated amount of hyperpolarization administered (r = 0. 77), but not with static lung volumes. We conclude that (3)He MRI is a sensitive measure to detect regional abnormalities in the distribution of ventilation in clinically healthy persons with normal pulmonary function tests. Copyright 2000 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10867694     DOI: 10.1002/1099-1492(200006)13:4<182::aid-nbm642>3.0.co;2-n

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  11 in total

1.  (3)He-MRI in follow-up of lung transplant recipients.

Authors:  Klaus Kurt Gast; Julia Zaporozhan; Sebastian Ley; Alexander Biedermann; Frank Knitz; Balthasar Eberle; Joerg Schmiedeskamp; Claus-Peter Heussel; Eckhard Mayer; Wolfgang Günter Schreiber; Manfred Thelen; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2003-10-16       Impact factor: 5.315

Review 2.  Morphological and functional imaging in COPD with CT and MRI: present and future.

Authors:  Julia Ley-Zaporozhan; Sebastian Ley; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2007-09-27       Impact factor: 5.315

Review 3.  Functional imaging: CT and MRI.

Authors:  Edwin J R van Beek; Eric A Hoffman
Journal:  Clin Chest Med       Date:  2008-03       Impact factor: 2.878

4.  Comparison of airway diameter measurements from an anthropomorphic airway tree phantom using hyperpolarized 3He MRI and high-resolution computed tomography.

Authors:  Yang-Sheng Tzeng; Eric Hoffman; Janice Cook-Granroth; Rie Maurer; Niral Shah; Joey Mansour; Juerg Tschirren; Mitchell Albert
Journal:  Magn Reson Med       Date:  2007-09       Impact factor: 4.668

5.  Posture-dependent human 3He lung imaging in an open-access MRI system: initial results.

Authors:  Leo L Tsai; Ross W Mair; Chih-Hao Li; Matthew S Rosen; Samuel Patz; Ronald L Walsworth
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

6.  Two-dimensional and three-dimensional oxygen mapping by 3He-MRI validation in a lung phantom.

Authors:  Klaus Kurt Gast; Wolfgang G Schreiber; Annette Herweling; Frank Lehmann; Gabor Erdös; Joerg Schmiedeskamp; Hans-Ulrich Kauczor; Balthasar Eberle
Journal:  Eur Radiol       Date:  2005-04-23       Impact factor: 5.315

Review 7.  [Functional 3He-MRI of the lungs].

Authors:  K K Gast; U Wolf
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

8.  Investigation of hyperpolarized 3He magnetic resonance imaging utility in examining human airway diameter behavior in asthma through comparison with high-resolution computed tomography.

Authors:  Yang-Sheng Tzeng; Eric Hoffman; Janice Cook-Granroth; Jessica Gereige; Joey Mansour; George Washko; Michael Cho; Evan Stepp; Kenneth Lutchen; Mitchell Albert
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

9.  Hyperpolarized Xe MR imaging of alveolar gas uptake in humans.

Authors:  Zackary I Cleveland; Gary P Cofer; Gregory Metz; Denise Beaver; John Nouls; S Sivaram Kaushik; Monica Kraft; Jan Wolber; Kevin T Kelly; H Page McAdams; Bastiaan Driehuys
Journal:  PLoS One       Date:  2010-08-16       Impact factor: 3.240

10.  Improving hyperpolarized 129 Xe ADC mapping in pediatric and adult lungs with uncertainty propagation.

Authors:  Abdullah S Bdaiwi; Peter J Niedbalski; Md M Hossain; Matthew M Willmering; Laura L Walkup; Hui Wang; Robert P Thomen; Kai Ruppert; Jason C Woods; Zackary I Cleveland
Journal:  NMR Biomed       Date:  2021-11-02       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.