Literature DB >> 12509822

Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI.

Ben T Chen1, Anja C S Brau, G Allan Johnson.   

Abstract

Dynamic regional lung function was investigated in rats using a radial acquisition cine (RA-CINE) pulse sequence together with hyperpolarized (HP) (3)He gas delivered by a constant flow ventilator. Based on regional differences in the behavior of inspired air, the lung was conceptually divided into two regions (the major airways and the peripheral airspace) for purposes of functional analysis. To measure regional function in the major airways, a large RF flip angle (24 degrees) was applied to reduce (3)He magnetization in the peripheral airspace, and signal intensity (SI) was normalized with the projected airway diameter to estimate local airflow. Higher normalized signal intensity was observed in the left branch airway as compared to the right branch airway. To determine regional function in the peripheral airspace, a small RF flip angle (6 degrees) was used. Incremental increases of peripheral SI in successive lung images were consistent with the increase in lung volume. A new "skipping" scanning strategy using dummy frames allows a trade-off between the number of frames acquired for dynamic information, the RF flip angle, and the penetration depth of (3)He magnetization into the lung. This work provides a novel approach to simultaneously assess dynamic regional function and morphology. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12509822     DOI: 10.1002/mrm.10336

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Quantification of airway diameters and 3D airway tree rendering from dynamic hyperpolarized 3He magnetic resonance imaging.

Authors:  Tina A Lewis; Yang-Sheng Tzeng; Erin L McKinstry; Angela C Tooker; Kwansoo Hong; Yanping Sun; Joey Mansour; Zachary Handler; Mitchell S Albert
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

Review 2.  Morphology of the small-animal lung using magnetic resonance microscopy.

Authors:  Laurence W Hedlund; G Allan Johnson
Journal:  Proc Am Thorac Soc       Date:  2005

3.  Measurement of the internal diameter of plastic tubes from projection MR images using a model-based least-squares fit approach.

Authors:  Yang-Sheng Tzeng; Joey Mansour; Zachary Handler; Jessica Gereige; Niral Shah; Xin Zhou; Mitchell Albert
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

4.  Imaging alveolar-capillary gas transfer using hyperpolarized 129Xe MRI.

Authors:  Bastiaan Driehuys; Gary P Cofer; Jim Pollaro; Julie Boslego Mackel; Laurence W Hedlund; G Allan Johnson
Journal:  Proc Natl Acad Sci U S A       Date:  2006-11-13       Impact factor: 11.205

5.  A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Authors:  Ming de Lin; Lutao Ning; Cristian T Badea; Nilesh N Mistry; Yi Qi; G Allan Johnson
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

6.  Comparison of airway diameter measurements from an anthropomorphic airway tree phantom using hyperpolarized 3He MRI and high-resolution computed tomography.

Authors:  Yang-Sheng Tzeng; Eric Hoffman; Janice Cook-Granroth; Rie Maurer; Niral Shah; Joey Mansour; Juerg Tschirren; Mitchell Albert
Journal:  Magn Reson Med       Date:  2007-09       Impact factor: 4.668

Review 7.  Small animal imaging with magnetic resonance microscopy.

Authors:  Bastiaan Driehuys; John Nouls; Alexandra Badea; Elizabeth Bucholz; Ketan Ghaghada; Alexandra Petiet; Laurence W Hedlund
Journal:  ILAR J       Date:  2008

8.  A Constant-Volume Ventilator and Gas Recapture System for Hyperpolarized Gas MRI of Mouse and Rat Lungs.

Authors:  John Nouls; Manuel Fanarjian; Laurence Hedlund; Bastiaan Driehuys
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-04       Impact factor: 1.176

9.  In vivo MRI using real-time production of hyperpolarized 129Xe.

Authors:  Bastiaan Driehuys; Jim Pollaro; Gary P Cofer
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

10.  3He MRI in mouse models of asthma.

Authors:  Bastiaan Driehuys; Julia Walker; Jim Pollaro; Gary P Cofer; Nilesh Mistry; David Schwartz; G Allan Johnson
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.