Literature DB >> 10673202

An analysis algorithm for measuring airway lumen and wall areas from high-resolution computed tomographic data.

G G King1, N L Müller, K P Whittall, Q S Xiang, P D Paré.   

Abstract

High-resolution computed tomography (HRCT) has been used to examine airway narrowing. We developed an automated computed tomographic image analysis algorithm (computed tomographic airway morphometry; CTAM) to measure airway lumen area (Ai ), airway wall area (Awa), and airway angle of orientation. Tubes of varying size were embedded in Styrofoam and then scanned at angles between 0 degrees and 50 degrees to assess the accuracy of measurements made with CTAM. Two excised pig lungs were fixed in inflation, sectioned, and scanned. Ai and Awa were measured planimetrically from the cut surfaces to optimize CTAM measurement parameters. In CTAM, Ai was defined according to an airway-size-dependent threshold value, and total Awa was determined through a score-guided erosion method. Results were compared with measurements made through a previously validated method (manual method). CTAM provided accurate measurements of the tubes' Ai values at all angles; Awa was overestimated in direct relation to airway size. The manual method underestimated Ai and overestimated Awa in a manner directly related to airway size as well as to airway angle of orientation. In the excised lung, the mean errors of Ai and Awa measurements made with CTAM were 0.52 +/- 0.24 mm(2) and 0.17 +/- 0.32 mm(2) (mean +/- SEM), respectively. Ai errors with the manual method were similar, but Awa was overestimated to a greater degree (6.3 +/- 0.38 mm(2); p < 0.01) and the error was proportional to Awa (r = 0.64; p < 0.01). CTAM allows accurate measurements of airway dimensions and angle of orientation.

Entities:  

Mesh:

Year:  2000        PMID: 10673202     DOI: 10.1164/ajrccm.161.2.9812073

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  35 in total

Review 1.  Quantitative pulmonary imaging using computed tomography and magnetic resonance imaging.

Authors:  George R Washko; Grace Parraga; Harvey O Coxson
Journal:  Respirology       Date:  2012-04       Impact factor: 6.424

2.  Adjusted subpixel method enables optimisation of bronchial measurements in high-resolution CT.

Authors:  G Mincewicz; A Aloszko; J Rumiński; G Krzykowski
Journal:  Br J Radiol       Date:  2012-01-31       Impact factor: 3.039

Review 3.  Airway imaging in disease: gimmick or useful tool?

Authors:  Peter D Paré; Taishi Nagano; Harvey O Coxson
Journal:  J Appl Physiol (1985)       Date:  2012-05-17

Review 4.  Assessment of lung function in children by cross-sectional imaging: techniques and clinical applications.

Authors:  Michael Puderbach; Hans-Ulrich Kauczor
Journal:  Pediatr Radiol       Date:  2005-11-15

5.  Intrathoracic airway trees: segmentation and airway morphology analysis from low-dose CT scans.

Authors:  Juerg Tschirren; Eric A Hoffman; Geoffrey McLennan; Milan Sonka
Journal:  IEEE Trans Med Imaging       Date:  2005-12       Impact factor: 10.048

6.  Segmentation and quantitative analysis of intrathoracic airway trees from computed tomography images.

Authors:  Juerg Tschirren; Eric A Hoffman; Geoffrey McLennan; Milan Sonka
Journal:  Proc Am Thorac Soc       Date:  2005

7.  Fully automated system for three-dimensional bronchial morphology analysis using volumetric multidetector computed tomography of the chest.

Authors:  Raman Venkatraman; Raghav Raman; Bhargav Raman; Richard B Moss; Geoffrey D Rubin; Lawrence H Mathers; Terry E Robinson
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

8.  Measurement of the internal diameter of plastic tubes from projection MR images using a model-based least-squares fit approach.

Authors:  Yang-Sheng Tzeng; Joey Mansour; Zachary Handler; Jessica Gereige; Niral Shah; Xin Zhou; Mitchell Albert
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

9.  Quantification of bronchial dimensions at MDCT using dedicated software.

Authors:  P Y Brillet; C I Fetita; C Beigelman-Aubry; A Saragaglia; D Perchet; F Preteux; P A Grenier
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

10.  Airway wall thickness assessed using computed tomography and optical coherence tomography.

Authors:  Harvey O Coxson; Brendan Quiney; Don D Sin; Li Xing; Annette M McWilliams; John R Mayo; Stephen Lam
Journal:  Am J Respir Crit Care Med       Date:  2008-02-28       Impact factor: 21.405

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.