Literature DB >> 17665166

[Imaging procedures to diagnose prostate cancer].

M Seitz1, B Scher, M Scherr, D Tilki, B Schlenker, C Gratzke, A Schipf, P Stanislaus, U Müller-Lisse, O Reich, C Stief.   

Abstract

Prostate cancer is one of the most frequent malignant diseases in men. Despite constant progress achieved in imaging procedures, prostate biopsy is the gold standard for diagnosing prostate cancer. For the assessment of lymph node status, only staging lymphadenectomy provides valid information. The aim of this work is to analyze the imaging procedures available in Germany and their value in primary and lymph node staging as well as biochemical recurrence.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17665166     DOI: 10.1007/s00120-007-1455-x

Source DB:  PubMed          Journal:  Urologe A        ISSN: 0340-2592            Impact factor:   0.639


  71 in total

1.  Prostate cancer: contrast-enhanced us for detection.

Authors:  E J Halpern; M Rosenberg; L G Gomella
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  11C-choline positron emission tomography in prostate cancer: primary staging and recurrent site staging.

Authors:  Soichiro Yoshida; Kazuaki Nakagomi; Shuichi Goto; Masami Futatsubashi; Tatsuo Torizuka
Journal:  Urol Int       Date:  2005       Impact factor: 2.089

3.  Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging.

Authors:  S Tong; H N Cardinal; R F McLoughlin; D B Downey; A Fenster
Journal:  Ultrasound Med Biol       Date:  1998-06       Impact factor: 2.998

4.  Preoperative staging of pelvic lymph nodes in prostate cancer by 11C-choline PET.

Authors:  Igle J de Jong; Jan Pruim; Philip H Elsinga; Willem Vaalburg; Han J Mensink
Journal:  J Nucl Med       Date:  2003-03       Impact factor: 10.057

5.  Staging of prostate cancer using 3-dimensional transrectal ultrasound images: a pilot study.

Authors:  S Garg; B Fortling; D Chadwick; M C Robinson; F C Hamdy
Journal:  J Urol       Date:  1999-10       Impact factor: 7.450

6.  Synthesis and evaluation of 18F-labeled choline as an oncologic tracer for positron emission tomography: initial findings in prostate cancer.

Authors:  T R DeGrado; R E Coleman; S Wang; S W Baldwin; M D Orr; C N Robertson; T J Polascik; D T Price
Journal:  Cancer Res       Date:  2001-01-01       Impact factor: 12.701

7.  Predictors of prostate carcinoma: accuracy of gray-scale and color Doppler US and serum markers.

Authors:  E Kuligowska; M A Barish; H M Fenlon; M Blake
Journal:  Radiology       Date:  2001-09       Impact factor: 11.105

8.  Important preoperative prognostic factors for extracapsular extension, seminal vesicle invasion and lymph node involvement in cases with radical retropubic prostatectomy.

Authors:  A Ozgür; F F Onol; L N Türkeri
Journal:  Int Urol Nephrol       Date:  2004       Impact factor: 2.370

9.  Development of (18)F-fluoroethylcholine for cancer imaging with PET: synthesis, biochemistry, and prostate cancer imaging.

Authors:  Toshihiko Hara; Noboru Kosaka; Hiroichi Kishi
Journal:  J Nucl Med       Date:  2002-02       Impact factor: 10.057

10.  Can Power Doppler enhanced transrectal ultrasound guided biopsy improve prostate cancer detection on first and repeat prostate biopsy?

Authors:  Mesut Remzi; Michael Dobrovits; Andreas Reissigl; Vincent Ravery; Mattias Waldert; Christian Wiunig; Yan Kit Fong; Bob Djavan
Journal:  Eur Urol       Date:  2004-10       Impact factor: 20.096

View more
  6 in total

Review 1.  [Diffusion-weighted MRI of the prostate].

Authors:  U G Mueller-Lisse; U L Mueller-Lisse; P Zamecnik; H-P W Schlemmer; M K Scherr
Journal:  Radiologe       Date:  2011-03       Impact factor: 0.635

Review 2.  [Imaging modalities for primary diagnosis and staging of prostate cancer].

Authors:  U G Mueller-Lisse; K Miller
Journal:  Urologe A       Date:  2010-02       Impact factor: 0.639

3.  [Impact of elastography in clinical diagnosis of prostate cancer. A comparison of cancer detection between B-mode sonography and elastography-guided 10-core biopsies].

Authors:  T Eggert; W Khaled; S Wenske; H Ermert; J Noldus
Journal:  Urologe A       Date:  2008-09       Impact factor: 0.639

4.  Comparison of meta-analyses among elastosonography (ES) and positron emission tomography/computed tomography (PET/CT) imaging techniques in the application of prostate cancer diagnosis.

Authors:  Qiaohong Ouyang; Zhongxiang Duan; Jixiao Lei; Guangli Jiao
Journal:  Tumour Biol       Date:  2015-09-29

5.  Identifying and analyzing different cancer subtypes using RNA-seq data of blood platelets.

Authors:  Yu-Hang Zhang; Tao Huang; Lei Chen; YaoChen Xu; Yu Hu; Lan-Dian Hu; Yudong Cai; Xiangyin Kong
Journal:  Oncotarget       Date:  2017-09-15

6.  Accuracy of shear wave elastography for the diagnosis of prostate cancer: A meta-analysis.

Authors:  Liang Sang; Xue-Mei Wang; Dong-Yang Xu; Yun-Fei Cai
Journal:  Sci Rep       Date:  2017-05-16       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.