Application of the noise power spectrum in modern diagnostic MDCT: part II. Noise power spectra and signal to noise.

K L Boedeker1, M F McNitt-Gray.   

Abstract

Balancing dose and image quality requires signal-to-noise (SNR) metrics which incorporate both the variance and the spatial frequency characteristics of noise. In this study, the non-prewhitening matched filter SNR metric is calculated for 2 mm slices of a 1 cm diameter sphere under three different conditions: (1) constant pixel standard deviation, (2) constant dose and (3) constant reconstruction filter. For the constant pixel standard deviation condition, an increase of 260% in SNR was found with increasing filter sharpness. For constant dose, the SNR remained level for smooth to medium filters, then declined by up to 55% with increasing filter sharpness. For a constant reconstruction filter, the SNR increased with dose, but not as high as photon statistics would predict. However, when structured noise was removed from the noise power spectrum, the SNR did vary with quanta statistics. These results offer protocol design guidance for low-frequency-dominated objects.

Mesh:

Year:  2007        PMID: 17664594     DOI: 10.1088/0031-9155/52/14/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  Local and global 3D noise power spectrum in cone-beam CT system with FDK reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

2.  Characterization of imaging performance in differential phase contrast CT compared with the conventional CT--noise power spectrum NPS(k).

Authors:  Xiangyang Tang; Yi Yang; Shaojie Tang
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Factors Affecting Dimensional Accuracy of 3-D Printed Anatomical Structures Derived from CT Data.

Authors:  Kent M Ogden; Can Aslan; Nathaniel Ordway; Dalanda Diallo; Gwen Tillapaugh-Fay; Pranav Soman
Journal:  J Digit Imaging       Date:  2015-12       Impact factor: 4.056

4.  Aliased noise in X-ray CT images and band-limiting processing as a preventive measure.

Authors:  Kazuhiro Sato; Miho Shidahara; Mitsunori Goto; Isao Yanagawa; Noriyasu Homma; Issei Mori
Journal:  Radiol Phys Technol       Date:  2015-01-11

5.  Fundamental relationship between the noise properties of grating-based differential phase contrast CT and absorption CT: theoretical framework using a cascaded system model and experimental validation.

Authors:  Ke Li; Nicholas Bevins; Joseph Zambelli; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  Control algorithms for dynamic attenuators.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

7.  Impact of bowtie filter and object position on the two-dimensional noise power spectrum of a clinical MDCT system.

Authors:  Daniel Gomez-Cardona; Juan Pablo Cruz-Bastida; Ke Li; Adam Budde; Jiang Hsieh; Guang-Hong Chen
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

8.  Noise suppression for dual-energy CT via penalized weighted least-square optimization with similarity-based regularization.

Authors:  Joseph Harms; Tonghe Wang; Michael Petrongolo; Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

9.  Tilted-wire method for measuring resolution properties of CT images under extremely low-contrast and high-noise conditions.

Authors:  Chiaki Tominaga; Hiroki Azumi; Mitsunori Goto; Masaaki Taura; Noriyasu Homma; Issei Mori
Journal:  Radiol Phys Technol       Date:  2018-02-23

10.  CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT.

Authors:  Alban Gervaise; Benoît Osemont; Sophie Lecocq; Alain Noel; Emilien Micard; Jacques Felblinger; Alain Blum
Journal:  Eur Radiol       Date:  2011-09-17       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.