Correction of CT artifacts and its influence on Monte Carlo dose calculations.

Magdalena Bazalova1, Luc Beaulieu, Steven Palefsky, Frank Verhaegena.   

Abstract

Computed tomography (CT) images of patients having metallic implants or dental fillings exhibit severe streaking artifacts. These artifacts may disallow tumor and organ delineation and compromise dose calculation outcomes in radiotherapy. We used a sinogram interpolation metal streaking artifact correction algorithm on several phantoms of exact-known compositions and on a prostate patient with two hip prostheses. We compared original CT images and artifact-corrected images of both. To evaluate the effect of the artifact correction on dose calculations, we performed Monte Carlo dose calculation in the EGSnrc/DOSXYZnrc code. For the phantoms, we performed calculations in the exact geometry, in the original CT geometry and in the artifact-corrected geometry for photon and electron beams. The maximum errors in 6 MV photon beam dose calculation were found to exceed 25% in original CT images when the standard DOSXYZnrc/CTCREATE calibration is used but less than 2% in artifact-corrected images when an extended calibration is used. The extended calibration includes an extra calibration point for a metal. The patient dose volume histograms of a hypothetical target irradiated by five 18 MV photon beams in a hypothetical treatment differ significantly in the original CT geometry and in the artifact-corrected geometry. This was found to be mostly due to miss-assignment of tissue voxels to air due to metal artifacts. We also developed a simple Monte Carlo model for a CT scanner and we simulated the contribution of scatter and beam hardening to metal streaking artifacts. We found that whereas beam hardening has a minor effect on metal artifacts, scatter is an important cause of these artifacts.

Entities:  

Mesh:

Year:  2007        PMID: 17654915     DOI: 10.1118/1.2736777

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Authors:  Pardis Ghafarian; S M R Aghamiri; Mohammad R Ay; Arman Rahmim; Thomas H Schindler; Osman Ratib; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-10-20       Impact factor: 9.236

2.  Computed tomographic beam-hardening artefacts: mathematical characterization and analysis.

Authors:  Hyoung Suk Park; Yong Eun Chung; Jin Keun Seo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

3.  Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

Authors:  Manuel Maerz; Oliver Koelbl; Barbara Dobler
Journal:  Strahlenther Onkol       Date:  2014-10-31       Impact factor: 3.621

4.  Evaluation of a commercial orthopaedic metal artefact reduction tool in radiation therapy of patients with head and neck cancer.

Authors:  H Kwon; K S Kim; Y M Chun; H-G Wu; J N K Carlson; J M Park; J-I Kim
Journal:  Br J Radiol       Date:  2015-05-20       Impact factor: 3.039

5.  An evaluation of three commercially available metal artifact reduction methods for CT imaging.

Authors:  Jessie Y Huang; James R Kerns; Jessica L Nute; Xinming Liu; Peter A Balter; Francesco C Stingo; David S Followill; Dragan Mirkovic; Rebecca M Howell; Stephen F Kry
Journal:  Phys Med Biol       Date:  2015-01-14       Impact factor: 3.609

6.  Approaches to reducing photon dose calculation errors near metal implants.

Authors:  Jessie Y Huang; David S Followill; Rebecca M Howell; Xinming Liu; Dragan Mirkovic; Francesco C Stingo; Stephen F Kry
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

7.  Improving image quality for digital breast tomosynthesis: an automated detection and diffusion-based method for metal artifact reduction.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Lubomir M Hadjiiski; Ravi K Samala
Journal:  Phys Med Biol       Date:  2017-09-15       Impact factor: 3.609

8.  Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid.

Authors:  Mehrsima Abdoli; Johan R de Jong; Jan Pruim; Rudi A J O Dierckx; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-18       Impact factor: 9.236

9.  The effects of the orthopedic metal artifact reduction (O-MAR) algorithm on contouring and dosimetry of head and neck radiotherapy patients.

Authors:  Jussi Sillanpaa; Michael Lovelock; Boris Mueller
Journal:  Med Dosim       Date:  2019-07-30       Impact factor: 1.482

10.  Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT.

Authors:  X-Y Gong; E Meyer; X-J Yu; J-H Sun; L-P Sheng; K-H Huang; R-Z Wu
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.