Literature DB >> 17646877

In situ detection of Bacillus anthracis spores using fully submersible, self-exciting, self-sensing PMN-PT/Sn piezoelectric microcantilevers.

John-Paul McGovern1, Wan Y Shih, Wei-Heng Shih.   

Abstract

In this study, we have demonstrated in situ, all-electrical detection of Bacillus anthracis (BA) spores using lead magnesium niobate-lead titanate/tin (PMN-PT/Sn) piezoelectric microcantilever sensors (PEMS) fabricated from PMN-PT freestanding films and electrically insulated with methyltrimethoxysilane (MTMS) coatings on the tin surface. Antibody specific to BA spore surface antigen was immobilized on the platinum electrode of the PMN-PT layer. In phosphate-buffered saline (PBS) solution, the PMN-PT/Sn PEMS exhibited quality (Q) values ranging from 50 to 75. The detection was carried out in a closed-loop flow cell with a liquid volume of 0.8 ml and a flow rate of 1 ml min(-1). It was shown that one sensor, "PEMS-A" (500 microm long, 800 microm wide, with a 22 microm thick PMN-PT layer, a 20 microm thick tin layer and a 1 +/- 0.5 x 10(-12) g Hz(-1) mass detection sensitivity) exhibited resonance frequency shifts of 2100 +/- 200, 1100 +/- 100 and 700 +/- 100 Hz at concentrations of 20,000, 2000, and 200 spores ml(-1) or 16,000, 1600, and 160 total spores, respectively. Additionally, "PEMS-B" (350 microm long, 800 microm wide, with an 8 microm thick PMN-PT layer, a 6 microm thick tin layer and a 2 +/- 1 x 10(-13) g Hz(-1) mass detection sensitivity) exhibited resonance frequency shifts of 2400 +/- 200, 1500 +/- 200, 500 +/- 150 and 200 +/- 100 Hz at concentrations of 20,000, 2000, 100, and 45 spores ml(-1) or 16,000, 1600, 80, and 36 total spores, respectively.

Entities:  

Mesh:

Year:  2007        PMID: 17646877     DOI: 10.1039/b704579d

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  14 in total

1.  Mechanism of flexural resonance frequency shift of a piezoelectric microcantilever sensor during humidity detection.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Appl Phys Lett       Date:  2008-05-09       Impact factor: 3.791

2.  Highly sensitive detection of HER2 extracellular domain in the serum of breast cancer patients by piezoelectric microcantilevers.

Authors:  LiNa Loo; Joseph A Capobianco; Wei Wu; Xiaotong Gao; Wan Y Shih; Wei-Heng Shih; Kambiz Pourrezaei; Matthew K Robinson; Gregory P Adams
Journal:  Anal Chem       Date:  2011-03-30       Impact factor: 6.986

3.  Regeneration of Arrayed Gold Microelectrodes Equipped for a Real-Time Cell Analyzer.

Authors:  Zhihui Xu; Yiyan Song; Huijun Jiang; Yan Kong; Xiaoming Li; Jin Chen; Yuan Wu
Journal:  J Vis Exp       Date:  2018-03-12       Impact factor: 1.355

4.  Label free detection of white spot syndrome virus using lead magnesium niobate-lead titanate piezoelectric microcantilever sensors.

Authors:  Joseph A Capobianco; Wei-Heng Shih; Jiann-Horng Leu; Grace Chu-Fang Lo; Wan Y Shih
Journal:  Biosens Bioelectron       Date:  2010-08-11       Impact factor: 10.618

5.  Enhanced Detection Resonance Frequency Shift of a Piezoelectric Microcantilever Sensor by a DC Bias Electric Field in Humidity Detection.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Sens Actuators B Chem       Date:  2009-04-24       Impact factor: 7.460

6.  Array lead zirconate titanate/glass piezoelectric microcantilevers for real-time detection of Bacillus anthracis with 10 spores/ml sensitivity and 1/1000 selectivity in bacterial mixtures.

Authors:  John-Paul McGovern; Wei-Heng Shih; Richard F Rest; Mitali Purohit; Mark Mattiucci; Kambiz Pourrezaei; Banu Onaral; Wan Y Shih
Journal:  Rev Sci Instrum       Date:  2009-12       Impact factor: 1.523

7.  Label-free Growth Receptor-2 Detection and Dissociation Constant Assessment in Diluted Human Serum Using a Longitudinal Extension Mode of a Piezoelectric Microcantilever Sensor.

Authors:  Joseph A Capobianco; Wan Y Shih; Gregory P Adams; Wei-Heng Shih
Journal:  Sens Actuators B Chem       Date:  2011-12-15       Impact factor: 7.460

8.  Label-free, all-electrical, in situ human epidermal growth receptor 2 detection.

Authors:  Joseph A Capobianco; Wan Y Shih; Qing-An Yuan; Gregory P Adams; Wei-Heng Shih
Journal:  Rev Sci Instrum       Date:  2008-07       Impact factor: 1.523

9.  Label-free flow-enhanced specific detection of Bacillus anthracis using a piezoelectric microcantilever sensor.

Authors:  John-Paul McGovern; Wan Y Shih; Richard Rest; Mitali Purohit; Yognandan Pandya; Wei-Heng Shih
Journal:  Analyst       Date:  2008-02-29       Impact factor: 4.616

Review 10.  Measurement of Mechanical Properties of Cantilever Shaped Materials.

Authors:  Eric Finot; Ali Passian; Thomas Thundat
Journal:  Sensors (Basel)       Date:  2008-05-26       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.