Literature DB >> 20161253

Enhanced Detection Resonance Frequency Shift of a Piezoelectric Microcantilever Sensor by a DC Bias Electric Field in Humidity Detection.

Qing Zhu1, Wan Y Shih, Wei-Heng Shih.   

Abstract

We have examined the relative longitudinal flexural resonance frequency shift of a PMN-PT/tin PEMS with a DC bias electric field, E, in humidity detection. We showed that the relative resonance frequency shift could be enhanced by applying an E to the PMN-PT layer during detection. A maximum enhancement of more than three times in resonance frequency shift was observed at E = -6 kV/cm as compared to the resonance frequency shift without a bias field. The maximal relative resonance frequency shift at E = -6 kV/cm was about 1000 times larger than could be accounted for by mass loading alone.

Entities:  

Year:  2009        PMID: 20161253      PMCID: PMC2711390          DOI: 10.1016/j.snb.2009.01.035

Source DB:  PubMed          Journal:  Sens Actuators B Chem        ISSN: 0925-4005            Impact factor:   7.460


  7 in total

1.  In situ, in-liquid, all-electrical detection of Salmonella typhimurium using lead titanate zirconate/gold-coated glass cantilevers at any dipping depth.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Biosens Bioelectron       Date:  2007-02-20       Impact factor: 10.618

2.  Mechanism of flexural resonance frequency shift of a piezoelectric microcantilever sensor during humidity detection.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Appl Phys Lett       Date:  2008-05-09       Impact factor: 3.791

3.  Real-Time, Label-Free, All-Electrical Detection of Salmonella typhimurium Using Lead Zirconate Titanate/Gold-Coated Glass Cantilevers at any Relative Humidity.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Sens Actuators B Chem       Date:  2007-08-08       Impact factor: 7.460

4.  Immunoassay of prostate-specific antigen (PSA) using resonant frequency shift of piezoelectric nanomechanical microcantilever.

Authors:  Jeong Hoon Lee; Kyo Seon Hwang; Jaebum Park; Ki Hyun Yoon; Dae Sung Yoon; Tae Song Kim
Journal:  Biosens Bioelectron       Date:  2005-04-15       Impact factor: 10.618

5.  In-situ quantitative analysis of a prostate-specific antigen (PSA) using a nanomechanical PZT cantilever.

Authors:  Kyo Seon Hwang; Jeong Hoon Lee; Jaebum Park; Dae Sung Yoon; Jung Ho Park; Tae Song Kim
Journal:  Lab Chip       Date:  2004-11-10       Impact factor: 6.799

6.  3-mercaptopropyltrimethoxysilane as insulating coating and surface for protein immobilization for piezoelectric microcantilever sensors.

Authors:  Joseph A Capobianco; Wan Y Shih; Wei-Heng Shih
Journal:  Rev Sci Instrum       Date:  2007-04       Impact factor: 1.523

7.  In situ detection of Bacillus anthracis spores using fully submersible, self-exciting, self-sensing PMN-PT/Sn piezoelectric microcantilevers.

Authors:  John-Paul McGovern; Wan Y Shih; Wei-Heng Shih
Journal:  Analyst       Date:  2007-06-18       Impact factor: 4.616

  7 in total
  6 in total

1.  Highly sensitive detection of HER2 extracellular domain in the serum of breast cancer patients by piezoelectric microcantilevers.

Authors:  LiNa Loo; Joseph A Capobianco; Wei Wu; Xiaotong Gao; Wan Y Shih; Wei-Heng Shih; Kambiz Pourrezaei; Matthew K Robinson; Gregory P Adams
Journal:  Anal Chem       Date:  2011-03-30       Impact factor: 6.986

2.  Amplification-free in situ KRAS point mutation detection at 60 copies per mL in urine in a background of 1000-fold wild type.

Authors:  Ceyhun E Kirimli; Wei-Heng Shih; Wan Y Shih
Journal:  Analyst       Date:  2016-02-21       Impact factor: 4.616

3.  Label-free Growth Receptor-2 Detection and Dissociation Constant Assessment in Diluted Human Serum Using a Longitudinal Extension Mode of a Piezoelectric Microcantilever Sensor.

Authors:  Joseph A Capobianco; Wan Y Shih; Gregory P Adams; Wei-Heng Shih
Journal:  Sens Actuators B Chem       Date:  2011-12-15       Impact factor: 7.460

4.  Analysis of detection enhancement using microcantilevers with long-slit-based sensors.

Authors:  Abdul-Rahim A Khaled; Kambiz Vafai
Journal:  Sensors (Basel)       Date:  2013-01-07       Impact factor: 3.576

5.  Analysis of deflection enhancement using epsilon assembly microcantilevers based sensors.

Authors:  Abdul-Rahim A Khaled; Kambiz Vafai
Journal:  Sensors (Basel)       Date:  2011-09-28       Impact factor: 3.576

6.  Simplified Aeroelastic Model for Fluid Structure Interaction between Microcantilever Sensors and Fluid Surroundings.

Authors:  Fei Wang; Liang Zhao; Yanling Zhang; Zhi Qiao
Journal:  PLoS One       Date:  2015-04-21       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.