Literature DB >> 20863681

Label free detection of white spot syndrome virus using lead magnesium niobate-lead titanate piezoelectric microcantilever sensors.

Joseph A Capobianco1, Wei-Heng Shih, Jiann-Horng Leu, Grace Chu-Fang Lo, Wan Y Shih.   

Abstract

We have investigated rapid, label free detection of white spot syndrome virus (WSSV) using the first longitudinal extension resonance peak of five lead-magnesium niobate-lead titanate (PMN-PT) piezoelectric microcantilever sensors (PEMS) 1050-700 μm long and 850-485 μm wide constructed from 8 μm thick PMN-PT freestanding films. The PMN-PT PEMS were encapsulated with a 3-mercaptopropyltrimethoxysilane (MPS) insulation layer and further coated with anti-VP28 and anti-VP664 antibodies to target the WSSV virions and nucleocapsids, respectively. By inserting the antibody coated PEMS in a flowing virion or nucleocapsid suspension, label free detection of the virions and nucleocapsids were respectively achieved by monitoring the PEMS resonance frequency shift. We showed that positive label free detection of both the virion and the nucleocapsid could be achieved at a concentration of 100virions(nucleocapsids)/ml or 10 virions(nucleocapsids)/100 μl, comparable to the detection sensitivity of polymerase chain reaction (PCR). However, in contrast to PCR, PEMS detection was label free, in situ and rapid (less than 30 min), potentially requiring minimal or no sample preparation.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20863681      PMCID: PMC3412145          DOI: 10.1016/j.bios.2010.08.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  19 in total

1.  In situ, in-liquid, all-electrical detection of Salmonella typhimurium using lead titanate zirconate/gold-coated glass cantilevers at any dipping depth.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Biosens Bioelectron       Date:  2007-02-20       Impact factor: 10.618

2.  Mechanism of flexural resonance frequency shift of a piezoelectric microcantilever sensor during humidity detection.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Appl Phys Lett       Date:  2008-05-09       Impact factor: 3.791

3.  Protein expression profiling of the shrimp cellular response to white spot syndrome virus infection.

Authors:  Hao-Ching Wang; Han-Ching Wang; Jiann-Horng Leu; Guang-Hsiung Kou; Andrew H-J Wang; Chu-Fang Lo
Journal:  Dev Comp Immunol       Date:  2006-12-05       Impact factor: 3.636

4.  Real-Time, Label-Free, All-Electrical Detection of Salmonella typhimurium Using Lead Zirconate Titanate/Gold-Coated Glass Cantilevers at any Relative Humidity.

Authors:  Qing Zhu; Wan Y Shih; Wei-Heng Shih
Journal:  Sens Actuators B Chem       Date:  2007-08-08       Impact factor: 7.460

5.  Application of spectrophotometry to evaluate the concentration of purified White Spot Syndrome Virus.

Authors:  Qing Zhou; Yi-Peng Qi; Feng Yang
Journal:  J Virol Methods       Date:  2007-09-04       Impact factor: 2.014

6.  In-situ quantitative analysis of a prostate-specific antigen (PSA) using a nanomechanical PZT cantilever.

Authors:  Kyo Seon Hwang; Jeong Hoon Lee; Jaebum Park; Dae Sung Yoon; Jung Ho Park; Tae Song Kim
Journal:  Lab Chip       Date:  2004-11-10       Impact factor: 6.799

7.  3-mercaptopropyltrimethoxysilane as insulating coating and surface for protein immobilization for piezoelectric microcantilever sensors.

Authors:  Joseph A Capobianco; Wan Y Shih; Wei-Heng Shih
Journal:  Rev Sci Instrum       Date:  2007-04       Impact factor: 1.523

8.  Monoclonal antibodies developed for sensitive detection and comparison of white spot syndrome virus isolates in India.

Authors:  T M Anil; K M Shankar; C V Mohan
Journal:  Dis Aquat Organ       Date:  2002-08-15       Impact factor: 1.802

9.  Genomic and proteomic analysis of thirty-nine structural proteins of shrimp white spot syndrome virus.

Authors:  Jyh-Ming Tsai; Han-Ching Wang; Jiann-Horng Leu; He-Hsuan Hsiao; Andrew H-J Wang; Guang-Hsiung Kou; Chu-Fang Lo
Journal:  J Virol       Date:  2004-10       Impact factor: 5.103

10.  In situ detection of Bacillus anthracis spores using fully submersible, self-exciting, self-sensing PMN-PT/Sn piezoelectric microcantilevers.

Authors:  John-Paul McGovern; Wan Y Shih; Wei-Heng Shih
Journal:  Analyst       Date:  2007-06-18       Impact factor: 4.616

View more
  7 in total

1.  Highly sensitive detection of HER2 extracellular domain in the serum of breast cancer patients by piezoelectric microcantilevers.

Authors:  LiNa Loo; Joseph A Capobianco; Wei Wu; Xiaotong Gao; Wan Y Shih; Wei-Heng Shih; Kambiz Pourrezaei; Matthew K Robinson; Gregory P Adams
Journal:  Anal Chem       Date:  2011-03-30       Impact factor: 6.986

2.  Label-free Growth Receptor-2 Detection and Dissociation Constant Assessment in Diluted Human Serum Using a Longitudinal Extension Mode of a Piezoelectric Microcantilever Sensor.

Authors:  Joseph A Capobianco; Wan Y Shih; Gregory P Adams; Wei-Heng Shih
Journal:  Sens Actuators B Chem       Date:  2011-12-15       Impact factor: 7.460

3.  Precise mass determination of single cell with cantilever-based microbiosensor system.

Authors:  Bogdan Łabędź; Aleksandra Wańczyk; Zenon Rajfur
Journal:  PLoS One       Date:  2017-11-21       Impact factor: 3.240

4.  Label-free sensitive detection of influenza virus using PZT discs with a synthetic sialylglycopolymer receptor layer.

Authors:  Alexander S Erofeev; Petr V Gorelkin; Dmitry V Kolesov; Gleb A Kiselev; Evgeniy V Dubrovin; Igor V Yaminsky
Journal:  R Soc Open Sci       Date:  2019-09-18       Impact factor: 2.963

5.  Development and validation of a quantitative real-time polymerase chain assay for universal detection of the White Spot Syndrome Virus in marine crustaceans.

Authors:  Fernando Mendoza-Cano; Arturo Sánchez-Paz
Journal:  Virol J       Date:  2013-06-07       Impact factor: 4.099

6.  Finite Element Analysis on Nanomechanical Detection of Small Particles: Toward Virus Detection.

Authors:  Gaku Imamura; Kota Shiba; Genki Yoshikawa
Journal:  Front Microbiol       Date:  2016-04-14       Impact factor: 5.640

7.  Electrochemical detection of white spot syndrome virus with a silicone rubber disposable electrode composed of graphene quantum dots and gold nanoparticle-embedded polyaniline nanowires.

Authors:  Kenshin Takemura; Jun Satoh; Jirayu Boonyakida; Sungjo Park; Ankan Dutta Chowdhury; Enoch Y Park
Journal:  J Nanobiotechnology       Date:  2020-10-27       Impact factor: 10.435

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.