Literature DB >> 17631509

Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery.

D Button1, L Weibel, O Reuthebuch, M Genoni, A Zollinger, C K Hofer.   

Abstract

BACKGROUND: Assessment of cardiac output (CO) by the FloTrac/Vigileo system may offer a less invasive means of determining the CO than either the pulmonary artery catheter (PAC) or the PiCCOplus system. The aim of this study was to compare CO measurements made using the FloTrac/Vigileo system with upgraded software (FCO, Edwards Lifesciences, Irvine CA, USA), the PiCCOplus system (PCO, Pulsion Medical Systems, Munich, Germany) and continuous CO monitoring using a PAC (CCO; Vigilance monitoring, Edwards Lifesciences, Irvine CA, USA) with intermittent pulmonary artery thermodilution (ICO). The study was conducted in patients undergoing elective cardiac surgery.
METHODS: Thirty-one patients with preserved left ventricular function were enrolled. CCO, FCO, and PCO were recorded in the perioperative period at six predefined time points after achieving stable haemodynamic conditions; ICO was determined from the mean of three bolus injections. Bland-Altman analysis was used to compare CCO, FCO, and PCO with ICO.
RESULTS: Bland-Altman analysis revealed a comparable mean bias and limits of agreement for all tested continuous CO monitoring devices using ICO as reference method. Agreement for all devices decreased in the postoperative period.
CONCLUSION: The performance of the FloTrac/Vigileo system, the PiCCOplus, and the Vigilance CCO monitoring for CO measurement were comparable when tested against intermittent thermodilution in patients undergoing elective cardiac surgery.

Entities:  

Mesh:

Year:  2007        PMID: 17631509     DOI: 10.1093/bja/aem188

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  41 in total

Review 1.  Cardiac output monitoring devices: an analytic review.

Authors:  Jahan Porhomayon; Ali El-Solh; Peter Papadakos; Nader Djalal Nader
Journal:  Intern Emerg Med       Date:  2011-12-07       Impact factor: 3.397

2.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

3.  Response to Dr. Bernstein's review: pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient.

Authors:  Francesco Forfori; Salvatore Mario Romano; Tania Balderi; Marco Anselmino; Francesco Giunta
Journal:  Obes Surg       Date:  2008-10-23       Impact factor: 4.129

Review 4.  [Haemodynamic monitoring in the perioperative phase. Available systems, practical application and clinical data].

Authors:  U Wittkowski; C Spies; M Sander; J Erb; A Feldheiser; C von Heymann
Journal:  Anaesthesist       Date:  2009-08       Impact factor: 1.041

Review 5.  Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient.

Authors:  Donald P Bernstein
Journal:  Obes Surg       Date:  2008-04-29       Impact factor: 4.129

Review 6.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

Review 7.  Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit.

Authors:  Jamal A Alhashemi; Maurizio Cecconi; Giorgio della Rocca; Maxime Cannesson; Christoph K Hofer
Journal:  Curr Heart Fail Rep       Date:  2010-09

8.  Effective evaluation of arterial pulse waveform analysis by two-dimensional stroke volume variation-stroke volume index plots.

Authors:  Teiji Sawa; Mao Kinoshita; Atsushi Kainuma; Koichi Akiyama; Yoshifumi Naito; Hideya Kato; Fumimasa Amaya; Keiji Shigemi
Journal:  J Clin Monit Comput       Date:  2016-08-04       Impact factor: 2.502

9.  Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study.

Authors:  Jan Benes; Ivan Chytra; Pavel Altmann; Marek Hluchy; Eduard Kasal; Roman Svitak; Richard Pradl; Martin Stepan
Journal:  Crit Care       Date:  2010-06-16       Impact factor: 9.097

10.  Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.

Authors:  Xavier Monnet; Nadia Anguel; Brice Naudin; Julien Jabot; Christian Richard; Jean-Louis Teboul
Journal:  Crit Care       Date:  2010-06-10       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.