Literature DB >> 26435581

Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules.

Sean O'Connor1, Paula Fey O'Connor1, H Amy Feng1, Kevin Ashley1.   

Abstract

An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 - 4 mg of National Institute of Standards and Technology Standard Reference Material® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision Sr at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝrt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules.

Entities:  

Year:  2014        PMID: 26435581      PMCID: PMC4587562     

Source DB:  PubMed          Journal:  Gefahrst Reinhalt Luft        ISSN: 0949-8036            Impact factor:   0.323


  8 in total

1.  Field comparison of 37-mm closed-face cassettes and IOM samplers.

Authors:  Martine Demange; Peter Görner; Jean-Marie Elcabache; Richard Wrobel
Journal:  Appl Occup Environ Hyg       Date:  2002-03

2.  Using a filter bypass leakage test for aerosol sampling cassettes.

Authors:  Paul A Baron
Journal:  Appl Occup Environ Hyg       Date:  2002-09

3.  Analytical performance criteria. Reconciling traditional accuracy assessment with the ISO guide to the expression of uncertainty in measurement (ISO/GUM).

Authors:  David L Bartley
Journal:  J Occup Environ Hyg       Date:  2004-04       Impact factor: 2.155

4.  Flow resistance of samplers for personal monitoring in work areas and requirements for sampling pump performance.

Authors:  Dietmar Breuer
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

5.  Concerning sampler wall deposits in the chemical analysis of airborne metals.

Authors:  Martin Harper; Martine Demange
Journal:  J Occup Environ Hyg       Date:  2007-09       Impact factor: 2.155

6.  Summary of the NIOSH guidelines for air sampling and analytical method development and evaluation.

Authors:  E R Kennedy; T J Fischbach; R Song; P M Eller; S A Shulman
Journal:  Analyst       Date:  1996-09       Impact factor: 4.616

7.  Laboratory investigation of the mass stability of sampling cassettes from inhalable aerosol samplers.

Authors:  J P Smith; D L Bartley; E R Kennedy
Journal:  Am Ind Hyg Assoc J       Date:  1998-08

8.  Closed-face filter cassette (CFC) sampling-guidance on procedures for inclusion of material adhering to internal sampler surfaces.

Authors:  Kevin Ashley; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

  8 in total
  2 in total

1.  NIOSH Manual of Analytical Methods 5th Edition and Harmonization of Occupational Exposure Monitoring.

Authors:  Kevin Ashley
Journal:  Gefahrst Reinhalt Luft       Date:  2015       Impact factor: 0.323

2.  Seasonal Characteristics and Particle-size Distributions of Particulate Air Pollutants in Urumqi.

Authors:  Xianyong Meng; Yiping Wu; Zhihua Pan; Hao Wang; Gang Yin; Honggang Zhao
Journal:  Int J Environ Res Public Health       Date:  2019-01-31       Impact factor: 3.390