Literature DB >> 17608342

Clinical outcomes of the Dynesys dynamic neutralization system: 1-year preliminary results.

William C Welch1, Boyle C Cheng, Tariq E Awad, Reginald Davis, James H Maxwell, Rick Delamarter, Jeffrey K Wingate, John Sherman, M Mason Macenski.   

Abstract

OBJECT: In this study the authors present the preliminary clinical outcomes of dynamic stabilization with the Dynesys spinal system as part of a multicenter randomized prospective Food and Drug Administration (FDA) investigational device exemption (IDE) clinical trial.
METHODS: This study included 101 patients from six IDE sites (no participants were omitted from the analysis) who underwent dynamic stabilization of the lumbar spine with the Dynesys construct. Patient participation was based on the presence of degenerative spondylolisthesis or retrolisthesis (Grade I), lateral or central spinal stenosis, and their physician's determination that the patient required decompression and instrumented fusion for one or two contiguous spinal levels between L-1 and S-1. Participants were evaluated preoperatively, postoperatively at 3 weeks, and then at 3-, 6-, and 12-month intervals. The 100-mm visual analog scale was used to score both lower-limb and back pain. Patient functioning was evaluated using the Oswestry Disability Index (ODI), and the participants' general health was assessed using the Short Form-12 questionnaire. Overall patient satisfaction was also reported. One hundred one patients (53 women and 48 men) with a mean age of 56.3 years (range 27-79 years) were included. The mean pain and function scores improved significantly from the baseline to 12-month follow-up evaluation, as follows: leg pain improved from 80.3 to 25.5, back pain from 54 to 29.4, and ODI score from 55.6 to 26.3%.
CONCLUSIONS: The early clinical outcomes of treatment with Dynesys are promising, with lessening of pain and disability found at follow-up review. Dynesys may be preferable to fusion for surgical treatment of degenerative spondylolisthesis and stenosis because it decreases back and leg pain while avoiding the relatively greater tissue destruction and the morbidity of donor site problems encountered in fusion. However, long-term follow-up care is still recommended.

Entities:  

Mesh:

Year:  2007        PMID: 17608342     DOI: 10.3171/foc.2007.22.1.8

Source DB:  PubMed          Journal:  Neurosurg Focus        ISSN: 1092-0684            Impact factor:   4.047


  26 in total

1.  Posterior dynamic stabilization of the lumbar spine with the Accuflex rod system as a stand-alone device: experience in 20 patients with 2-year follow-up.

Authors:  Alejandro Reyes-Sánchez; Barón Zárate-Kalfópulos; Isabel Ramírez-Mora; Luis Miguel Rosales-Olivarez; Armando Alpizar-Aguirre; Guadalupe Sánchez-Bringas
Journal:  Eur Spine J       Date:  2010-05-22       Impact factor: 3.134

2.  The effect of design parameters of dynamic pedicle screw systems on kinematics and load bearing: an in vitro study.

Authors:  C Schilling; S Krüger; T M Grupp; G N Duda; W Blömer; A Rohlmann
Journal:  Eur Spine J       Date:  2010-11-26       Impact factor: 3.134

3.  Short-term effects of a dynamic neutralization system (Dynesys) for multi-segmental lumbar disc herniation.

Authors:  Qi Wang; Jun Liu; Ying Shi; Yu Chen; Hailong Yu; Junxiong Ma; Weijian Ren; Huifeng Yang; Hongwei Wang; Liangbi Xiang
Journal:  Eur Spine J       Date:  2015-11-17       Impact factor: 3.134

4.  Advanced Multi-Axis Spine Testing: Clinical Relevance and Research Recommendations.

Authors:  Timothy P Holsgrove; Nikhil R Nayak; William C Welch; Beth A Winkelstein
Journal:  Int J Spine Surg       Date:  2015-07-17

5.  Market approval processes for new types of spinal devices: challenges and recommendations for improvement.

Authors:  Arno Bisschop; Maurits W van Tulder
Journal:  Eur Spine J       Date:  2016-05-27       Impact factor: 3.134

6.  Segment-by-segment stabilization for degenerative disc disease: a hybrid technique.

Authors:  Othmar Schwarzenbach; Nathalie Rohrbach; Ulrich Berlemann
Journal:  Eur Spine J       Date:  2010-02-04       Impact factor: 3.134

7.  Clinical experience of the dynamic stabilization system for the degenerative spine disease.

Authors:  Soo-Eon Lee; Sung-Bae Park; Tae-Ahn Jahng; Chun-Kee Chung; Hyun-Jib Kim
Journal:  J Korean Neurosurg Soc       Date:  2008-05-20

8.  Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients.

Authors:  Fras Dakhil-Jerew; H Jadeja; A Cohen; J A N Shepperd
Journal:  Eur Spine J       Date:  2009-06-16       Impact factor: 3.134

9.  NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study.

Authors:  Jeffrey D Coe; Scott H Kitchel; Hans Jörg Meisel; Charles H Wingo; Soo Eon Lee; Tae-Ahn Jahng
Journal:  J Korean Neurosurg Soc       Date:  2012-06-30

10.  Minimum ten-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization.

Authors:  Kotryna Veresciagina; Arne Mehrkens; Stefan Schären; Bernhard Jeanneret
Journal:  J Spine Surg       Date:  2018-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.