Literature DB >> 29732428

Minimum ten-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization.

Kotryna Veresciagina1, Arne Mehrkens1, Stefan Schären1, Bernhard Jeanneret1.   

Abstract

BACKGROUND: The Dynesys system remains the most widely implanted posterior non-fusion pedicle screw system. Various study designs used in investigations with good to excellent short- and mid-term results have been reported in the current literature. However, there is a lack of information concerning long-term outcomes following treatment for spinal stenosis with degenerative spondylolisthesis.
METHODS: The aim of our study was twofold. Firstly, to assess whether the dynamic stabilization in situ with the Dynesys System without bone grafting provides enough stability to prevent progression of spondylolisthesis and secondarily to maintain significant clinical improvement in a long-term follow-up (FU). Therefore, the consecutive patients due to inclusion criterions underwent interlaminar decompression and stabilization with Dynesys instrumentation. Patients were evaluated clinically and radiologically after a minimum FU of 10 years.
RESULTS: At FU, the mean low back pain (LBP) post-operatively and leg pain (LP) post-operatively on visual analog scale (VAS) and North American Spine Society (NASS) improved significantly (P<0.001) compared to preoperative examination. The mean value of NASS neurogenic symptoms (19.13% and 4.72%) and activity subscores were 23.13% and 10.74% respectively. In plain and functional radiographs the mean listhesis grade in neutral position was 11.11%, 11.8% in reclination and 11.63% in inclination. There were 17 and 8 patients with progressing degenerative osteochondrosis/listhesis at adjacent segments.
CONCLUSIONS: Decompression and single and double level dynamic in situ stabilization with the Dynesys System demonstrate good clinical and radiological long-term results in elderly patients.

Entities:  

Keywords:  Degenerative spondylolisthesis; Dynesys; North American Spine Society lumbar questionnaire (NASS lumbar questionnaire); adjacent segment degeneration (ASD); finger floor distance (FFD); spinal stenosis; visual analog scale (VAS); walking distance (WD)

Year:  2018        PMID: 29732428      PMCID: PMC5911763          DOI: 10.21037/jss.2018.03.20

Source DB:  PubMed          Journal:  J Spine Surg        ISSN: 2414-4630


  44 in total

1.  Radiographic and clinical results of posterior dynamic stabilization for the treatment of multisegment degenerative disc disease with a minimum follow-up of 3 years.

Authors:  Shang-Won Yu; Cheng-Yo Yen; Chin-Hsien Wu; Feng-Chen Kao; Yu-Hsien Kao; Yuan-Kun Tu
Journal:  Arch Orthop Trauma Surg       Date:  2012-01-20       Impact factor: 3.067

2.  [System of dynamic neutralization in the lumbar spine: experience on 94 cases].

Authors:  M Bordes-Monmeneu; V Bordes-Garcia; F Rodrigo-Baeza; D Saez
Journal:  Neurocirugia (Astur)       Date:  2005-12       Impact factor: 0.553

3.  Graf ligament stabilisation: mid- to long-term follow-up.

Authors:  M C Rigby; G P Selmon; M A Foy; A J Fogg
Journal:  Eur Spine J       Date:  2001-06       Impact factor: 3.134

4.  The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis.

Authors:  K H Bridwell; T A Sedgewick; M F O'Brien; L G Lenke; C Baldus
Journal:  J Spinal Disord       Date:  1993-12

5.  Clinical experience of the dynamic stabilization system for the degenerative spine disease.

Authors:  Soo-Eon Lee; Sung-Bae Park; Tae-Ahn Jahng; Chun-Kee Chung; Hyun-Jib Kim
Journal:  J Korean Neurosurg Soc       Date:  2008-05-20

6.  Minimum four-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization.

Authors:  Stefan Schaeren; Ivan Broger; Bernhard Jeanneret
Journal:  Spine (Phila Pa 1976)       Date:  2008-08-15       Impact factor: 3.468

7.  Postoperative instability after decompression for lumbar spinal stenosis.

Authors:  K E Johnsson; S Willner; K Johnsson
Journal:  Spine (Phila Pa 1976)       Date:  1986-03       Impact factor: 3.468

8.  Long-term Outcome After Monosegmental L4/5 Stabilization for Degenerative Spondylolisthesis With the Dynesys Device.

Authors:  Sven Hoppe; Othmar Schwarzenbach; Emin Aghayev; Harald Bonel; Ulrich Berlemann
Journal:  Clin Spine Surg       Date:  2016-03       Impact factor: 1.876

9.  The impact of adjacent level disc degeneration on health status outcomes following lumbar fusion.

Authors:  Thomas W Throckmorton; Alan S Hilibrand; Gregory A Mencio; Arleen Hodge; Dan M Spengler
Journal:  Spine (Phila Pa 1976)       Date:  2003-11-15       Impact factor: 3.468

10.  Clinical outcomes of the Dynesys dynamic neutralization system: 1-year preliminary results.

Authors:  William C Welch; Boyle C Cheng; Tariq E Awad; Reginald Davis; James H Maxwell; Rick Delamarter; Jeffrey K Wingate; John Sherman; M Mason Macenski
Journal:  Neurosurg Focus       Date:  2007-12-15       Impact factor: 4.047

View more
  5 in total

1.  Preoperative facet joint arthropathy does not impact long-term clinical outcomes after lumbar-stability-preserving decompression and dynesys fixation.

Authors:  Po-Hsin Chou; Hsi-Hsien Lin; Yu-Cheng Yao; Shih-Tien Wang; Ming-Chau Chang; Chien-Lin Liu
Journal:  Sci Rep       Date:  2021-05-28       Impact factor: 4.379

2.  Mobility-Preserving Surgery for Lumbar Spinal Stenosis: WFNS Spine Committee Recommendations.

Authors:  Ben Roitberg; Mehmet Zileli; Salman Sharif; Carla Anania; Maurizio Fornari; Francesco Costa
Journal:  World Neurosurg X       Date:  2020-03-19

3.  Is Dynesys dynamic stabilization system superior to posterior lumbar fusion in the treatment of lumbar degenerative diseases?

Authors:  Bao-Gan Peng; Chun-Hua Gao
Journal:  World J Clin Cases       Date:  2020-11-26       Impact factor: 1.337

4.  Effect of Discectomy on Dynesys Dynamic Fixation in the Treatment of Lumbar Degenerative Diseases.

Authors:  Chen Zhao; Liehua Liu; Lei Luo; Pei Li; Yiyang Wang; Lichuan Liang; Xueping Wen; Dianming Jiang; Qiang Zhou
Journal:  Pain Res Manag       Date:  2021-12-30       Impact factor: 3.037

5.  Adjacent segment disease following Dynesys stabilization for lumbar disorders: A case series of mid- and long-term follow-ups.

Authors:  Kuan-Ju Chen; Chien-Ying Lai; Lu-Ting Chiu; Wei-Sheng Huang; Pang-Hsuan Hsiao; Chien-Chun Chang; Cheng-Jyh Lin; Yuan-Shun Lo; Yen-Jen Chen; Hsien-Te Chen
Journal:  World J Clin Cases       Date:  2021-12-16       Impact factor: 1.337

  5 in total