Literature DB >> 17605366

Postoperative calculation of acetabular cup position using 2-D-3-D registration.

Graeme P Penney1, Philip J Edwards, John H Hipwell, Mike Slomczykowski, Ian Revie, David J Hawkes.   

Abstract

A method to accurately measure the position and orientation of an acetabular cup implant from postoperative X-rays has been designed and validated. The method uses 2-D-3-D registration to align both the prosthesis and the preoperative computed tomography (CT) volume to the X-ray image. This allows the position of the implant to be calculated with respect to a CT-based surgical plan. Experiments have been carried out using ten sets of patient data. A conventional plain-film measurement technique was also investigated. A gold standard implant position and orientation was calculated using postoperative CT. Results show our method to be significantly more accurate than the plain-film method for calculating cup anteversion. Cup orientation and position could be measured to within a mean absolute error of 1.4 mm or degrees.

Entities:  

Mesh:

Year:  2007        PMID: 17605366     DOI: 10.1109/TBME.2007.890737

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  10 in total

1.  Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

Authors:  Guoyan Zheng
Journal:  J Digit Imaging       Date:  2009-07-21       Impact factor: 4.056

2.  Computer assisted determination of acetabular cup orientation using 2D-3D image registration.

Authors:  Guoyan Zheng; Xuan Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-02-24       Impact factor: 2.924

3.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

Review 4.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

5.  Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA.

Authors:  G Zheng; J von Recum; L-P Nolte; P A Grützner; S D Steppacher; J Franke
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-07-27       Impact factor: 2.924

6.  The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital.

Authors:  Mark C Callanan; Bryan Jarrett; Charles R Bragdon; David Zurakowski; Harry E Rubash; Andrew A Freiberg; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

7.  A new 2D-3D registration gold-standard dataset for the hip joint based on uncertainty modeling.

Authors:  Fabio D'Isidoro; Christophe Chênes; Stephen J Ferguson; Jérôme Schmid
Journal:  Med Phys       Date:  2021-08-17       Impact factor: 4.506

8.  Ellipse method for measuring Liaw's anteversion of the acetabular component after total hip arthroplasty.

Authors:  Kuei-Lin Yeh; Tai-Yin Wu; Hsuan-Hsiao Ma; Sheng-Mou Hou; Chen-Kun Liaw
Journal:  BMC Musculoskelet Disord       Date:  2020-10-08       Impact factor: 2.362

Review 9.  Navigated cup implantation in hip arthroplasty.

Authors:  Johannes Beckmann; Dirk Stengel; Markus Tingart; Jürgen Götz; Joachim Grifka; Christian Lüring
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

10.  The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs.

Authors:  Yang Soo Park; Won Chul Shin; Sang Min Lee; Sang Ho Kwak; Jung Yun Bae; Kuen Tak Suh
Journal:  J Orthop Surg Res       Date:  2018-04-02       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.