Literature DB >> 17600741

Enhanced diffusion weighting generated by selective adiabatic pulse trains.

Ziqi Sun1, Robert Bartha.   

Abstract

A theoretical description and experimental validation of the enhanced diffusion weighting generated by selective adiabatic full passage (AFP) pulse trains is provided. Six phantoms (Ph-1-Ph-6) were studied on a 4 T Varian/Siemens whole body MRI system. Phantoms consisted of 2.8 cm diameter plastic tubes containing a mixture of 10 microm ORGASOL polymer beads and 2mM Gd-DTPA dissolved in 5% agar (Ph-1) or nickel(II) ammonium sulphate hexahydrate doped (56.3-0.8 mM) water solutions (Ph-2-Ph-6). A customized localization by adiabatic selective refocusing (LASER) sequence containing slice selective AFP pulse trains and pulsed diffusion gradients applied in the phase encoding direction was used to measure (1)H(2)O diffusion. The b-value associated with the LASER sequence was derived using the Bloch-Torrey equation. The apparent diffusion coefficients measured by LASER were comparable to those measured by a conventional pulsed gradient spin-echo (PGSE) sequence for all phantoms. Image signal intensity increased in Ph-1 and decreased in Ph-2-Ph-6 as AFP pulse train length increased while maintaining a constant echo-time. These experimental results suggest that such AFP pulse trains can enhance contrast between regions containing microscopic magnetic susceptibility variations and homogeneous regions in which dynamic dephasing relaxation mechanisms are dominant.

Entities:  

Mesh:

Year:  2007        PMID: 17600741      PMCID: PMC2075527          DOI: 10.1016/j.jmr.2007.05.019

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  8 in total

1.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR.

Authors:  M Garwood; L DelaBarre
Journal:  J Magn Reson       Date:  2001-12       Impact factor: 2.229

2.  In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast.

Authors:  Robert Bartha; Shalom Michaeli; Hellmut Merkle; Gregor Adriany; Peter Andersen; Wei Chen; Kamil Ugurbil; Michael Garwood
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

3.  A reduced power selective adiabatic spin-echo pulse sequence.

Authors:  S Conolly; G Glover; D Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1991-03       Impact factor: 4.668

4.  Improved gradient-echo 3D magnetic resonance imaging using pseudo-echoes created by frequency-swept pulses.

Authors:  Jang-Yeon Park; Lance DelaBarre; Michael Garwood
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

5.  Experimental validation of a T2rho transverse relaxation model using LASER and CPMG acquisitions.

Authors:  Simona Nikolova; Chris V Bowen; Robert Bartha
Journal:  J Magn Reson       Date:  2006-04-17       Impact factor: 2.229

6.  Exchange-influenced T2rho contrast in human brain images measured with adiabatic radio frequency pulses.

Authors:  Shalom Michaeli; Heidi Gröhn; Olli Gröhn; Dennis J Sorce; Risto Kauppinen; Charles S Springer; Kâmil Uğurbil; Michael Garwood
Journal:  Magn Reson Med       Date:  2005-04       Impact factor: 4.668

7.  Use of frequency-modulated radiofrequency pulses in MR imaging experiments.

Authors:  D Kunz
Journal:  Magn Reson Med       Date:  1986-06       Impact factor: 4.668

Review 8.  Iron oxide MR contrast agents for molecular and cellular imaging.

Authors:  Jeff W M Bulte; Dara L Kraitchman
Journal:  NMR Biomed       Date:  2004-11       Impact factor: 4.044

  8 in total
  1 in total

1.  Whole brain mapping of water pools and molecular dynamics with rotating frame MR relaxation using gradient modulated low-power adiabatic pulses.

Authors:  Ovidiu C Andronesi; Himanshu Bhat; Martin Reuter; Shreya Mukherjee; Peter Caravan; Bruce R Rosen
Journal:  Neuroimage       Date:  2013-12-15       Impact factor: 6.556

  1 in total