Literature DB >> 16616533

Experimental validation of a T2rho transverse relaxation model using LASER and CPMG acquisitions.

Simona Nikolova1, Chris V Bowen, Robert Bartha.   

Abstract

The transverse relaxation rate (R2=1/T2) of many biological tissues are altered by endogenous magnetized particles (i.e., ferritin, deoxyhemoglobin), and may be sensitive to the pathological progression of neurodegenerative disorders associated with altered brain-iron stores. R2 measurements using Carr-Purcell-Meiboom-Gill (CPMG) acquisitions are sensitive to the refocusing pulse interval (2taucp), and have been modeled as a chemical exchange (CE) process, while R2 measurements using a localization by adiabatic selective refocusing (LASER) sequence have an additional relaxation rate contribution that has been modeled as a R2rho process. However, no direct comparison of the R2 measured using these two sequences has been described for a controlled phantom model of magnetized particles. The three main objectives of this study were: (1) to compare the accuracy of R2 relaxation rate predictions from the CE model with experimental data acquired using a conventional CPMG sequence, (2) to compare R2 estimates obtained using LASER and CPMG acquisitions, and (3) to determine whether the CE model, modified to account for R2rho relaxation, adequately describes the R2 measured by LASER for a full range of taucp values. In all cases, our analysis was confined to spherical magnetic particles that satisfied the weak field regime. Three phantoms were produced that contained spherical magnetic particles (10 microm diameter polyamide powders) suspended in Gd-DTPA (1.0, 1.5, and 2.0 mmol/L) doped gel. Mono-exponential R2 measurements were made at 4T as a function of refocusing pulse interval. CPMG measurements of R2 agreed with CE model predictions while significant differences in R2 estimates were observed between LASER and CPMG measurements for short taucp acquisitions. The discrepancy between R2 estimates is shown to be attributable to contrast enhancement in LASER due to T2rho relaxation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16616533     DOI: 10.1016/j.jmr.2006.03.013

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  2 in total

1.  Enhanced diffusion weighting generated by selective adiabatic pulse trains.

Authors:  Ziqi Sun; Robert Bartha
Journal:  J Magn Reson       Date:  2007-06-09       Impact factor: 2.229

2.  Comparison of T2 and LASER T2dagger image contrast in a rat model of acute cerebral ischemia.

Authors:  Simona Nikolova; Ziqi Sun; Miranda Bellyou; Robert Bartha
Journal:  Magn Reson Imaging       Date:  2007-12-03       Impact factor: 2.546

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.