Literature DB >> 3724417

Use of frequency-modulated radiofrequency pulses in MR imaging experiments.

D Kunz.   

Abstract

With increasing field strength for whole-body MR scanners there is a need for rf pulses of higher bandwidth to perform selective excitation or inversion. AM pulses will have to become shorter thus leading to an enormous requirement for the peak power of the power amplifier. To reduce these requirements the use of frequency modulation is investigated. The effect of pulses based on a linear frequency sweep on the spin system is analyzed by calculation and computer simulation. It turns out that the nonlinear phases induced by those pulses may compensate each other, that therefore spin-echo experiments as usual in MR imaging may be performed, and that the required peak power may be reduced by up to a factor of 50.

Mesh:

Year:  1986        PMID: 3724417     DOI: 10.1002/mrm.1910030303

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Enhanced diffusion weighting generated by selective adiabatic pulse trains.

Authors:  Ziqi Sun; Robert Bartha
Journal:  J Magn Reson       Date:  2007-06-09       Impact factor: 2.229

2.  Improved half RF slice selectivity in the presence of eddy currents with out-of-slice saturation.

Authors:  Sonal Josan; Elena Kaye; John M Pauly; Bruce L Daniel; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

3.  Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants.

Authors:  Noam Ben-Eliezer; Eddy Solomon; Elad Harel; Nava Nevo; Lucio Frydman
Journal:  MAGMA       Date:  2012-06-29       Impact factor: 2.310

4.  Gapped pulses for frequency-swept MRI.

Authors:  Djaudat Idiyatullin; Curt Corum; Steen Moeller; Michael Garwood
Journal:  J Magn Reson       Date:  2008-05-20       Impact factor: 2.229

5.  Alleviating artifacts in 1H MRI thermometry by single scan spatiotemporal encoding.

Authors:  Rita Schmidt; Lucio Frydman
Journal:  MAGMA       Date:  2013-02-27       Impact factor: 2.310

6.  Arbitrary waveform modulated pulse EPR at 200GHz.

Authors:  Ilia Kaminker; Ryan Barnes; Songi Han
Journal:  J Magn Reson       Date:  2017-04-27       Impact factor: 2.229

7.  Spatiotemporal encoding as a robust basis for fast three-dimensional in vivo MRI.

Authors:  Noam Ben-Eliezer; Lucio Frydman
Journal:  NMR Biomed       Date:  2011-02-28       Impact factor: 4.044

8.  Continuous SWIFT.

Authors:  Djaudat Idiyatullin; Steven Suddarth; Curtis A Corum; Gregor Adriany; Michael Garwood
Journal:  J Magn Reson       Date:  2012-05-09       Impact factor: 2.229

9.  Multi-Band-SWIFT.

Authors:  Djaudat Idiyatullin; Curtis A Corum; Michael Garwood
Journal:  J Magn Reson       Date:  2014-12-10       Impact factor: 2.229

10.  Spin-echo MRI using pi/2 and pi hyperbolic secant pulses.

Authors:  Jang-Yeon Park; Michael Garwood
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.