| Literature DB >> 17598907 |
Bernd Gagel1, Marc Piroth, Michael Pinkawa, Patrick Reinartz, Michael Zimny, Hans J Kaiser, Sven Stanzel, Branka Asadpour, Cengiz Demirel, Kurt Hamacher, Heinz H Coenen, Thomas Scholbach, Payam Maneschi, Ercole DiMartino, Michael J Eble.
Abstract
BACKGROUND: The present study was conducted to analyze the value of ([18F] fluoromisonidazole (FMISO) and [18F]-2-fluoro-2'-deoxyglucose (FDG) PET as well as color pixel density (CPD) and tumor perfusion (TP) assessed by color duplex sonography (CDS) for determination of therapeutic relevant hypoxia. As a standard for measuring tissue oxygenation in human tumors, the invasive, computerized polarographic needle electrode system (pO2 histography) was used for comparing the different non invasive measurements.Entities:
Mesh:
Substances:
Year: 2007 PMID: 17598907 PMCID: PMC1948005 DOI: 10.1186/1471-2407-7-113
Source DB: PubMed Journal: BMC Cancer ISSN: 1471-2407 Impact factor: 4.430
Correlations between different relevant polarographically measured parameters of tumor hypoxia, FMISO PET, CDS and FDG PET data based oxygenation values
| ≤2.5 mmHg | ≤5.0 mmHg | ≤10.0 mmHg | Median pO2 | Mean pO2 | FMISOT/M | FMISOT/B | CPD | TP | FDGSUVmax | FDGSUVmean | |
| ≤2.5 mmHg | |||||||||||
| N | 36 | 20 | 20 | 28 | |||||||
| ≤5.0 mmHg | |||||||||||
| N | 36 | 36 | 20 | 20 | 28 | 16 | |||||
| ≤10.0 mmHg | |||||||||||
| N | 36 | 36 | 36 | 20 | 20 | 28 | 16 | ||||
| Mean pO2 | |||||||||||
| N | 36 | 36 | 36 | 20 | 28 | 16 | |||||
| Mean pO2 | |||||||||||
| N | 36 | 36 | 36 | 36 | 36 | 20 | 28 | 16 | |||
| FMISOT/M | |||||||||||
| N | 22 | 22 | 22 | 22 | 24 | ||||||
| FMISOT/B | |||||||||||
| N | 22 | 24 | 24 | ||||||||
| CPD | |||||||||||
| N | 31 | 31 | 31 | 31 | 31 | 18 | 32 | ||||
| TP | |||||||||||
| N | 18 | 18 | 18 | 9 | 18 | 18 | |||||
| FDGSUVmax | |||||||||||
| N | 24 | 24 | |||||||||
| FDGSUVmean | |||||||||||
| N | 24 | 24 |
Correlations after exclusion of outliers in the marked right upper columns of the table; relevant correlation marked by bold numbers; r = Pearson coefficient of correlation; N = number of correlated measurements.
Figure 1Scatter plots visualizing type of association between selected polarographic parameters (median pO2, hypoxic fraction ≤ 2.5 mmHg and ≤ 5.0 mmHg) and color pixel density (CPD) as well as FMISO tumor to muscle ratio (FMISOT/M) after 2 h (→ marked outliers). Left graphs: scatter plots using all available data values. Right graphs: corresponding scatter plots after exclusion of marked outliers identified in the left graph.
Figure 2From left to right: transaxial FDG PET-, transaxial FMISO PET-, CDS- and transaxial CT scans in two different patients. A:with a normoxic tumor (pO2 ≤ 2.5 mmHg = 13.0%, pO2 ≤ 5.0 mmHg = 15.1%, pO2 ≤ 10.0 mmHg = 17.0%, median pO2 = 36.2 mmHg, mean pO2 = 41.1 mmHg; CPD = 12.05%; FDGSUVmax = 17.84, FDGSUVmean = 14.80; FMISOT/M = 1.31, FMISOT/B = 1.07). B:with a hypoxic tumorB (pO2 ≤ 2.5 mmHg = 37.7%, pO2 ≤ 5.0 mmHg = 48.8%, pO2 ≤ 10.0 mmHg = 58.1%, median pO2 = 5.5 mmHg, mean pO2 = 17.7 mmHg; CPD = 2.71%; FDGSUVmax = 9.34, FDGSUVmean = 8.00; FMISOT/M = 1.60, FMISOT/B = 0.88). 1/2 = distance measurements for the guidance of the polarographic needle electrode
Figure 3Outlier patient 4, transaxial FDG PET- (A), transaxial FMISO PET- (B), CDS- (C) and transaxial CT (D) scans (pO2 = 2.5 mmHg= 43.0%, pO2 = 5.0 mmHg = 53.0%, pO2 = 10.0 mmHg = 71.5%, median pO2 = 3.7 mmHg, mean pO2 = 8.8 mmHg; CPD = 2.96%; FDGSUVmax = 4.80, FDGSUVmean = 4.55; FMISOT/M = 1.19, FMISOT/B = 1.11). 1/2 = distance measurements for the guidance of the polarographic needle electrode.