OBJECTIVES: Systematic review of diagnostic accuracy of contrast enhanced coronary computed tomography (CE-CCT).
BACKGROUND: Noninvasive detection of coronary artery stenosis (CAS) by CE-CCT as an alternative to catheter-based coronary angiography (CCA) may improve patient management.
METHODS: Forty-one articles published between 1997 and 2006 were included that evaluated native coronary arteries for significant stenosis and used CE-CCT as diagnostic test and CCA as reference standard. Study group characteristics, study methodology and diagnostic outcomes were extracted. Pooled summary sensitivity and specificity of CE-CCT were calculated using a random effects model (1) for all coronary segments, (2) assessable segments, and (3) per patient.
RESULTS: The 41 studies totaled 2515 patients (75% males; mean age: 59 years, CAS prevalence: 59%). Analysis of all coronary segments yielded a sensitivity of 95% (80%, 89%, 86%, 98% for electron beam CT, 4/8-slice, 16-slice and 64-slice MDCT, respectively) for a specificity of 85% (77%, 84%, 95%, 91%). Analysis limited to segments deemed assessable by CT showed sensitivity of 96% (86%, 85%, 98%, 97%) for a specificity of 95% (90%, 96%, 96%, 96%). Per patient, sensitivity was 99% (90%, 97%, 99%, 98%) and specificity was 76% (59%, 81%, 83%, 92%). Heterogeneity was quantitatively important but not explainable by patient group characteristics or study methodology.
CONCLUSIONS: Current diagnostic accuracy of CE-CCT is high. Advances in CT technology have resulted in increases in diagnostic accuracy and proportion of assessable coronary segments. However, per patient, accuracy may be lower and CT may have more limited clinical utility in populations at high risk for CAD.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17590554     DOI: 10.1016/j.ejrad.2007.05.003

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  28 in total

Review 1.  New insights from major prospective cohort studies with cardiac CT.

Authors:  Sumbal A Janjua; Udo Hoffmann
Journal:  Curr Cardiol Rep       Date:  2015       Impact factor: 2.931

2.  Effect of kVp on image quality and accuracy in coronary CT angiography according to patient body size: a phantom study.

Authors:  Sang Min Lee; Whal Lee; Jin Wook Chung; Eun-Ah Park; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2013-11-02       Impact factor: 2.357

3.  Using multidetector computed tomography in a swine model to assess the effects of sublingual nitroglycerin and intravenous adenosine on epicardial coronary arteries.

Authors:  Wesley A Clarkson; Carlos Santiago Restrepo; Terry D Bauch; Bernard J Rubal
Journal:  Comp Med       Date:  2009-12       Impact factor: 0.982

4.  The role of calcium score and CT angiography in the medical management of patients with normal myocardial perfusion imaging.

Authors:  Gaurav Choudhary; Victor Shin; Shahnaz Punjani; Nathan Ritter; Satish C Sharma; Wen-Chih Wu
Journal:  J Nucl Cardiol       Date:  2010 Jan-Feb       Impact factor: 5.952

5.  Association of coronary plaque burden with fractional flow reserve: should we keep attempting to derive physiology from anatomy?

Authors:  Thura T Abd; Richard T George
Journal:  Cardiovasc Diagn Ther       Date:  2015-02

6.  Efficiency and safety of coronary CT angiography compared to standard care in the evaluation of patients with acute chest pain: a Canadian study.

Authors:  Elena Peña; Fraser Rubens; Ian Stiell; Rebecca Peterson; Joao Inacio; Carole Dennie
Journal:  Emerg Radiol       Date:  2016-05-24

7.  Adolescent Kawasaki disease: usefulness of 64-slice CT coronary angiography for follow-up investigation.

Authors:  Iacopo Carbone; David Cannata; Emanuela Algeri; Nicola Galea; Alessandro Napoli; Andrea De Zorzi; Giovanna Bosco; Rita D'Agostino; Leon Menezes; Carlo Catalano; Roberto Passariello; Marco Francone
Journal:  Pediatr Radiol       Date:  2011-06-30

8.  Impact of PVCs noted during coronary calcium scan on image quality and accuracy in subsequent coronary dual-source CT angiography.

Authors:  Wolfgang Eicher; Thomas Kau; Martin Niedermayer; Birgit Senft; Maria Sinzig; Birgit Strozyk; Klaus Armin Hausegger
Journal:  Int J Cardiovasc Imaging       Date:  2010-09-11       Impact factor: 2.357

9.  Coronary CT Angiography as a Diagnostic and Prognostic Tool: Perspective from a Multicenter Randomized Controlled Trial: PROMISE.

Authors:  Daniel O Bittner; Maros Ferencik; Pamela S Douglas; Udo Hoffmann
Journal:  Curr Cardiol Rep       Date:  2016-05       Impact factor: 2.931

10.  Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid PET/CT scanner.

Authors:  S Kajander; H Ukkonen; H Sipilä; M Teräs; J Knuuti
Journal:  Clin Physiol Funct Imaging       Date:  2008-11-06       Impact factor: 2.273

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.