Literature DB >> 17577482

Monitoring the effectiveness of cleaning in four British hospitals.

Rose A Cooper1, Chris J Griffith, Rifhat E Malik, Peter Obee, Nick Looker.   

Abstract

BACKGROUND: A survey of cleaning effectiveness was conducted in two wards in four acute hospitals in England and Wales. Surfaces were monitored immediately before and after cleaning on three separate occasions using visual assessment, adenosine triphosphate (ATP) bioluminescence, expressed in relative light units (RLUs), and microbiological methods (aerobic colony counts [ACC]), expressed in colony forming units (cfu) per cm(2).
METHODS: Comparison of data from a total of over 3000 assessments showed highly significant differences in failure rates between visual assessment and either ATP or microbiological counts. There was no significant difference in failure rates between ATP and microbiological counts. Using visual assessment, failure rates were significantly lower after cleaning than before. Using ATP or microbiological methods, failure rates were not significantly different after cleaning.
RESULTS: Data obtained using both ATP and ACC, indicated considerable variability after cleaning and that failed surfaces were often well in excess of benchmark values.
CONCLUSIONS: Cumulatively, the results indicate that visual assessment is not a reliable indicator of surface cleanliness or of cleaning efficacy. Concerns also arise about the standards of surface cleanliness achieved after cleaning in the hospitals.

Entities:  

Mesh:

Year:  2007        PMID: 17577482     DOI: 10.1016/j.ajic.2006.07.015

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  15 in total

1.  Swab type, moistening, and preenrichment for Staphylococcus aureus on environmental surfaces.

Authors:  Timothy F Landers; Armando Hoet; Thomas E Wittum
Journal:  J Clin Microbiol       Date:  2010-04-14       Impact factor: 5.948

2.  What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.

Authors:  Raveesh Daniel Richard; Thomas R Bowen
Journal:  Clin Orthop Relat Res       Date:  2017-07       Impact factor: 4.176

3.  Improved eradication of Clostridium difficile spores from toilets of hospitalized patients using an accelerated hydrogen peroxide as the cleaning agent.

Authors:  Michelle J Alfa; Evelyn Lo; Alana Wald; Christine Dueck; Pat DeGagne; Godfrey K M Harding
Journal:  BMC Infect Dis       Date:  2010-09-15       Impact factor: 3.090

4.  Adenosine triphosphate bioluminescence assay for monitoring contamination of the working environment of anaesthetists and cleanliness of the operating room.

Authors:  Tomoko Fukada; Yuri Tsuchiya; Hiroko Iwakiri; Makoto Ozaki
Journal:  J Infect Prev       Date:  2014-11-13

5.  Bioluminescence ATP monitoring for the routine assessment of food contact surface cleanliness in a university canteen.

Authors:  Andrea Osimani; Cristiana Garofalo; Francesca Clementi; Stefano Tavoletti; Lucia Aquilanti
Journal:  Int J Environ Res Public Health       Date:  2014-10-17       Impact factor: 3.390

6.  Anti-microbial activities of pomegranate rind extracts: enhancement by cupric sulphate against clinical isolates of S. aureus, MRSA and PVL positive CA-MSSA.

Authors:  Simon W J Gould; Mark D Fielder; Alison F Kelly; Declan P Naughton
Journal:  BMC Complement Altern Med       Date:  2009-07-27       Impact factor: 3.659

7.  Controlling methicillin-resistant Staphylococcus aureus (MRSA) in a hospital and the role of hydrogen peroxide decontamination: an interrupted time series analysis.

Authors:  Brett G Mitchell; Wilhelmine Digney; Phil Locket; Stephanie J Dancer
Journal:  BMJ Open       Date:  2014-04-19       Impact factor: 2.692

8.  Effectiveness of visual inspection compared with non-microbiologic methods to determine the thoroughness of post-discharge cleaning.

Authors:  Graham M Snyder; Aleah D Holyoak; Katharine E Leary; Bernadette F Sullivan; Roger B Davis; Sharon B Wright
Journal:  Antimicrob Resist Infect Control       Date:  2013-10-02       Impact factor: 4.887

9.  Use of a Sampling Area-Adjusted Adenosine Triphosphate Bioluminescence Assay Based on Digital Image Quantification to Assess the Cleanliness of Hospital Surfaces.

Authors:  Yu-Huai Ho; Lih-Shinn Wang; Hui-Li Jiang; Chih-Hui Chang; Chia-Jung Hsieh; Dan-Chi Chang; Hsin-Yu Tu; Tan-Yun Chiu; Huei-Jen Chao; Chun-Chieh Tseng
Journal:  Int J Environ Res Public Health       Date:  2016-06-09       Impact factor: 3.390

Review 10.  Effectiveness of ATP bioluminescence to assess hospital cleaning: a review.

Authors:  N Nante; E Ceriale; G Messina; D Lenzi; P Manzi
Journal:  J Prev Med Hyg       Date:  2017-06
View more