Literature DB >> 17574487

On the radiobiological impact of metal artifacts in head-and-neck IMRT in terms of tumor control probability (TCP) and normal tissue complication probability (NTCP).

Yusung Kim1, Wolfgang A Tomé.   

Abstract

To investigate the effects of distorted head-and-neck (H&N) intensity-modulated radiation therapy (IMRT) dose distributions (hot and cold spots) on normal tissue complication probability (NTCP) and tumor control probability (TCP) due to dental-metal artifacts. Five patients' IMRT treatment plans have been analyzed, employing five different planning image data-sets: (a) uncorrected (UC); (b) homogeneous uncorrected (HUC); (c) sinogram completion corrected (SCC); (d) minimum-value-corrected (MVC); and (e) streak-artifact-reduction including minimum-value-correction (SAR-MVC), which has been taken as the reference data-set. The effects on NTCP and TCP were evaluated using the Lyman-NTCP model and the Logistic-TCP model, respectively. When compared to the predicted NTCP obtained using the reference data-set, the treatment plan based on the original CT data-set (UC) yielded an increase in NTCP of 3.2 and 2.0% for the spared parotid gland and the spinal cord, respectively. While for the treatment plans based on the MVC CT data-set the NTCP increased by a 1.1% and a 0.1% for the spared parotid glands and the spinal cord, respectively. In addition, the MVC correction method showed a reduction in TCP for target volumes (MVC: delta TCP = -0.6% vs. UC: delta TCP = -1.9%) with respect to that of the reference CT data-set. Our results indicate that the presence of dental-metal-artifacts in H&N planning CT data-sets has an impact on the estimates of TCP and NTCP. In particular dental-metal-artifacts lead to an increase in NTCP for the spared parotid glands and a slight decrease in TCP for target volumes.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17574487     DOI: 10.1007/s11517-007-0196-8

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  30 in total

1.  Iterative approaches to dose optimization in tomotherapy.

Authors:  D M Shepard; G H Olivera; P J Reckwerdt; T R Mackie
Journal:  Phys Med Biol       Date:  2000-01       Impact factor: 3.609

2.  Optically guided intensity modulated radiotherapy.

Authors:  W A Tomé; S L Meeks; T R McNutt; J M Buatti; F J Bova; W A Friedman; M Mehta
Journal:  Radiother Oncol       Date:  2001-10       Impact factor: 6.280

3.  The relation between tumour lethal doses and the radiosensitivity of tumour cells.

Authors:  T R MUNRO; C W GILBERT
Journal:  Br J Radiol       Date:  1961-04       Impact factor: 3.039

Review 4.  Tomotherapy and other innovative IMRT delivery systems.

Authors:  John D Fenwick; Wolfgang A Tomé; Emilie T Soisson; Minesh P Mehta; T Rock Mackie
Journal:  Semin Radiat Oncol       Date:  2006-10       Impact factor: 5.934

5.  Calculation of complication probability factors for non-uniform normal tissue irradiation: the effective volume method.

Authors:  G J Kutcher; C Burman
Journal:  Int J Radiat Oncol Biol Phys       Date:  1989-06       Impact factor: 7.038

6.  The use of megavoltage CT (MVCT) images for dose recomputations.

Authors:  K M Langen; S L Meeks; D O Poole; T H Wagner; T R Willoughby; P A Kupelian; K J Ruchala; J Haimerl; G H Olivera
Journal:  Phys Med Biol       Date:  2005-08-31       Impact factor: 3.609

7.  Implementation of a model for estimating tumor control probability for an inhomogeneously irradiated tumor.

Authors:  A Niemierko; M Goitein
Journal:  Radiother Oncol       Date:  1993-11       Impact factor: 6.280

8.  On cold spots in tumor subvolumes.

Authors:  Wolfgang A Tomé; Jack F Fowler
Journal:  Med Phys       Date:  2002-07       Impact factor: 4.071

9.  A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell density.

Authors:  S Webb; A E Nahum
Journal:  Phys Med Biol       Date:  1993-06       Impact factor: 3.609

10.  On the inclusion of proliferation in tumour control probability calculations for inhomogeneously irradiated tumours.

Authors:  Wolfgang A Tomé; Jack F Fowler
Journal:  Phys Med Biol       Date:  2003-09-21       Impact factor: 3.609

View more
  6 in total

1.  World Congress on Medical Physics and Biomedical Engineering (WC2006, Seoul).

Authors:  Eung Je Woo; Hee-Joung Kim; Jos A E Spaan
Journal:  Med Biol Eng Comput       Date:  2007-11-15       Impact factor: 2.602

2.  An enhanced random walk algorithm for delineation of head and neck cancers in PET studies.

Authors:  Alessandro Stefano; Salvatore Vitabile; Giorgio Russo; Massimo Ippolito; Maria Gabriella Sabini; Daniele Sardina; Orazio Gambino; Roberto Pirrone; Edoardo Ardizzone; Maria Carla Gilardi
Journal:  Med Biol Eng Comput       Date:  2016-09-16       Impact factor: 2.602

3.  Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

Authors:  Manuel Maerz; Oliver Koelbl; Barbara Dobler
Journal:  Strahlenther Onkol       Date:  2014-10-31       Impact factor: 3.621

Review 4.  Dental management in head and neck cancers: from intensity-modulated radiotherapy with photons to proton therapy.

Authors:  Sabah Falek; Rajesh Regmi; Joel Herault; Melanie Dore; Anthony Vela; Pauline Dutheil; Cyril Moignier; Pierre-Yves Marcy; Julien Drouet; Arnaud Beddok; Noah E Letwin; Joel Epstein; Upendra Parvathaneni; Juliette Thariat
Journal:  Support Care Cancer       Date:  2022-05-05       Impact factor: 3.359

5.  Redefine the Role of Spot-Scanning Proton Beam Therapy for the Single Brain Metastasis Stereotactic Radiosurgery.

Authors:  Sheng Chang; Gang Liu; Lewei Zhao; Weili Zheng; Di Yan; Peter Chen; Xiangpan Li; Kunyu Yang; Rohan Deraniyagala; Craig Stevens; Inga Grills; Prakash Chinnaiyan; Xiaoqiang Li; Xuanfeng Ding
Journal:  Front Oncol       Date:  2022-05-19       Impact factor: 5.738

6.  MR-based CT metal artifact reduction for head-and-neck photon, electron, and proton radiotherapy.

Authors:  Jonathan Scharff Nielsen; Koen Van Leemput; Jens Morgenthaler Edmund
Journal:  Med Phys       Date:  2019-08-10       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.