Optically guided intensity modulated radiotherapy.

W A Tomé1, S L Meeks, T R McNutt, J M Buatti, F J Bova, W A Friedman, M Mehta.   

Abstract

BACKGROUND AND
PURPOSE: Previously, we reported on development of an optically guided system for 3D conformal intracranial radiotherapy using multiple noncoplanar fixed fields. In this paper we report on the extension of our system for stereotactic fractionated radiotherapy to include intensity modulated static ports. METHODS AND MATERIALS: A 3D treatment plan with maximum beam separation is developed in the stereotactic space established by an optically guided system. Gantry angles are chosen such that each beam has a unique entrance and exit pathway, avoids the critical structures, and has a minimal beam's eye view projection. Once, a satisfactory treatment plan is found using this geometric approach an inverse treatment plan is developed using the beam portals established previously. The purpose of adding inverse planing is two fold, on the one hand it allows further reduction of margins around the PTV, while on the other hand it affords the possibility of conformal avoidance of critical structures that are close to or abut the PTV.
RESULTS: The use of the optically guided system in conjunction with intensity modulated noncoplanar radiotherapy treatment planning using fixed fields allows the generation of highly conformal treatment plans that exhibit smaller 90, 70, and 50% of prescription dose isodose volumes, improved PITV ratios, comparable or improved EUD, smaller NTD(mean) for the critical structures, and an inhomogeneity index that is within generally accepted limits.
CONCLUSION: Because optically guided technology improves the accuracy of patient localization relative to the linac isocenter and allows real-time monitoring of patient position, the planning target volume needs to be corrected only for the limitations of image resolution. Intensity modulated static beam radiotherapy planning then provides the user the ability to further reduce margins on the PTV and to conform very closely to this smaller target volume, and enhances the normal tissue sparing, and high degree of conformality possible with 3D conformal radiotherapy. In addition, since optically guided technology affords improved patient localization and online monitoring of patient position during treatment delivery it allows for safe and efficient delivery of intensity modulated radiotherapy.

Entities:  

Mesh:

Year:  2001        PMID: 11578726     DOI: 10.1016/s0167-8140(01)00414-5

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  11 in total

1.  On the radiobiological impact of metal artifacts in head-and-neck IMRT in terms of tumor control probability (TCP) and normal tissue complication probability (NTCP).

Authors:  Yusung Kim; Wolfgang A Tomé
Journal:  Med Biol Eng Comput       Date:  2007-06-16       Impact factor: 2.602

2.  Hippocampal dosimetry predicts neurocognitive function impairment after fractionated stereotactic radiotherapy for benign or low-grade adult brain tumors.

Authors:  Vinai Gondi; Bruce P Hermann; Minesh P Mehta; Wolfgang A Tomé
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-12-29       Impact factor: 7.038

3.  Radiosurgery technology development and use.

Authors:  Sanford L Meeks; Jason Pukala; Naren Ramakrishna; Twyla R Willoughby; Francis J Bova
Journal:  J Radiosurg SBRT       Date:  2011

4.  Acute hematologic and mucosal toxicities in head and neck cancer patients undergoing chemoradiotherapy: a comparison of 3D-CRT, IMRT, and helical tomotherapy.

Authors:  Tim J Kruser; Stephanie R Rice; Kevin P Cleary; Heather M Geye; Wolfgang A Tome; Paul M Harari; Kevin R Kozak
Journal:  Technol Cancer Res Treat       Date:  2013-03-26

5.  Dosimetric impact of daily setup variations during treatment of canine nasal tumors using intensity-modulated radiation therapy.

Authors:  Michael A Deveau; Alonso N Gutiérrez; Thomas R Mackie; Wolfgang A Tomé; Lisa J Forrest
Journal:  Vet Radiol Ultrasound       Date:  2010 Jan-Feb       Impact factor: 1.363

6.  Evaluation of a fast method of EPID-based dosimetry for intensity-modulated radiation therapy.

Authors:  Benjamin E Nelms; Karl H Rasmussen; Wolfgang A Tome
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

7.  Single institution experience treating 104 vestibular schwannomas with fractionated stereotactic radiation therapy or stereotactic radiosurgery.

Authors:  Bethany M Anderson; Deepak Khuntia; Søren M Bentzen; Heather M Geye; Lori L Hayes; John S Kuo; Mustafa K Baskaya; Behnam Badie; Amar Basavatia; G Mark Pyle; Wolfgang A Tomé; Minesh P Mehta
Journal:  J Neurooncol       Date:  2013-10-20       Impact factor: 4.130

8.  Medical physics practice in the next decade.

Authors:  Bhudatt Paliwal
Journal:  J Med Phys       Date:  2006-07

9.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

10.  Improvement of therapeutic index for brain tumors with daily image guidance.

Authors:  Lisa Be Shields; James M Coons; Catherine Dedich; Maria Ragains; Kristi Scalf; Todd W Vitaz; Aaron C Spalding
Journal:  Radiat Oncol       Date:  2013-12-02       Impact factor: 3.481