Evaluation of bone response to titanium-coated polymethyl methacrylate resin (PMMA) implants by X-ray tomography.

Manal M Shalabi1, Johannes G C Wolke, Vincent M J I Cuijpers, John A Jansen.   

Abstract

High-resolution three-dimensional data about the bone response to oral implants can be obtained by using microfocus computer tomography. However, a disadvantage is that metallic implants cause streaking artifacts due to scattering of X-rays, which prevents an accurate evaluation of the interfacial bone-to-implant contact. It has been suggested that the use of thin titanium coatings deposited on polymeric implants can offer an alternative option for analyzing bone contact using micro-CT imaging. Consequently, the aim of the current study was to investigate bone behavior to titanium-coated polymethylmethacrylate (PMMA) implants by micro-CT and histological evaluation. For the experiment titanium-coated PMMA implants were used. The implants had a machined threaded appearance and were provided with a 400-500 nm thick titanium coating. The implants were inserted in the right or left tibia of 10 goats. After an implantation period of 12 weeks the implants were retrieved and prepared for micro-computer tomography (microCT), light microscopy, and X-ray microanalysis. The micro-CT showed that the screw-threads and typical implant configuration were well maintained through the installation procedure. Overall, histological responses showed that the titanium-coated implants were well tolerated and caused no atypical tissue response. In addition, the bone was seen in direct contact with the titanium-coated layer. The X-ray microanalysis results confirmed the light microscopical data. In conclusion, the obtained results proof the final use of titanium-coated PMMA implants for evaluation of the bone-implant response using microCT. However, this study also confirms that for a proper analysis of the bone-implant interface the additional use of microscopical techniques is still required.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17558472     DOI: 10.1007/s10856-007-3160-0

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  16 in total

1.  Comparison of microfocus- and synchrotron X-ray tomography for the analysis of osteointegration around Ti6Al4V implants.

Authors:  R Bernhardt; D Scharnweber; B Müller; P Thurner; H Schliephake; P Wyss; F Beckmann; J Goebbels; H Worch
Journal:  Eur Cell Mater       Date:  2004-06-30       Impact factor: 3.942

2.  Induced tissue integration of bone implants by coating with bone selective RGD-peptides in vitro and in vivo studies.

Authors:  P Schaffner; J Meyer; M Dard; R Wenz; B Nies; S Verrier; H Kessler; M Kantlehner
Journal:  J Mater Sci Mater Med       Date:  1999-12       Impact factor: 3.896

3.  A light and electron microscopic study of the effects of surface topography on the behavior of cells attached to titanium-coated percutaneous implants.

Authors:  B Chehroudi; T R Gould; D M Brunette
Journal:  J Biomed Mater Res       Date:  1991-03

4.  Osteoconductive modifications of Ti-implants in a goat defect model: characterization of bone growth with SR muCT and histology.

Authors:  Ricardo Bernhardt; Juliette van den Dolder; Sussane Bierbaum; Rene Beutner; Dieter Scharnweber; John Jansen; Felix Beckmann; Hartmut Worch
Journal:  Biomaterials       Date:  2005-06       Impact factor: 12.479

5.  Correlation between microtomography and histomorphometry for assessment of implant osseointegration.

Authors:  Young-Seok Park; Ki-Young Yi; In-Seop Lee; Young-Chul Jung
Journal:  Clin Oral Implants Res       Date:  2005-04       Impact factor: 5.977

6.  Validation of microfocus computed tomography in the evaluation of bone implant specimens.

Authors:  Nele Stoppie; Jan-Paul van der Waerden; John A Jansen; Joke Duyck; Martine Wevers; Ignace E Naert
Journal:  Clin Implant Dent Relat Res       Date:  2005       Impact factor: 3.932

7.  Ultrastructural study of epithelial cell attachment to implant materials.

Authors:  J A Jansen; J R de Wijn; J M Wolters-Lutgerhorst; P J van Mullem
Journal:  J Dent Res       Date:  1985-06       Impact factor: 6.116

8.  Bone healing in porous implants: a histological and histometrical comparative study on sheep.

Authors:  Y L Liu; J Schoenaers; K Groot Kd; J R Wijn; E Schepers
Journal:  J Mater Sci Mater Med       Date:  2000-11       Impact factor: 3.896

9.  Stretch-mediated responses of osteoblast-like cells cultured on titanium-coated substrates in vitro.

Authors:  X F Walboomers; W J E M Habraken; B Feddes; L C Winter; J D Bumgardner; J A Jansen
Journal:  J Biomed Mater Res A       Date:  2004-04-01       Impact factor: 4.396

10.  Histological evaluation of the bone response to calcium phosphate cement implanted in cortical bone.

Authors:  E M Ooms; J G C Wolke; M T van de Heuvel; B Jeschke; J A Jansen
Journal:  Biomaterials       Date:  2003-03       Impact factor: 12.479

View more
  7 in total

1.  Enhanced corrosion resistance and cytocompatibility of biomimetic hyaluronic acid functionalised silane coating on AZ31 Mg alloy for orthopaedic applications.

Authors:  Sankalp Agarwal; Marie-Noelle Labour; David Hoey; Brendan Duffy; James Curtin; Swarna Jaiswal
Journal:  J Mater Sci Mater Med       Date:  2018-08-28       Impact factor: 3.896

2.  Ultrasonic Evaluation of the Bone-Implant Interface.

Authors:  Yoann Hériveaux; Vu-Hieu Nguyen; Guillaume Haïat
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

3.  The potential role of polymethyl methacrylate as a new packaging material for the implantable medical device in the bladder.

Authors:  Su Jin Kim; Bumkyoo Choi; Kang Sup Kim; Woong Jin Bae; Sung Hoo Hong; Ji Youl Lee; Tae-Kon Hwang; Sae Woong Kim
Journal:  Biomed Res Int       Date:  2015-02-01       Impact factor: 3.411

4.  Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study.

Authors:  Adrien Michel; Romain Bosc; Jean-Paul Meningaud; Philippe Hernigou; Guillaume Haiat
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

5.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

6.  Elastography of the bone-implant interface.

Authors:  Yoann Hériveaux; Vu-Hieu Nguyen; Didier Geiger; Guillaume Haïat
Journal:  Sci Rep       Date:  2019-10-02       Impact factor: 4.379

7.  Quantitative ultrasound assessment of the influence of roughness and healing time on osseointegration phenomena.

Authors:  M Fraulob; R Vayron; S Le Cann; B Lecuelle; Y Hériveaux; H Albini Lomami; C H Flouzat Lachaniette; G Haïat
Journal:  Sci Rep       Date:  2020-12-15       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.