Literature DB >> 15777324

Correlation between microtomography and histomorphometry for assessment of implant osseointegration.

Young-Seok Park1, Ki-Young Yi, In-Seop Lee, Young-Chul Jung.   

Abstract

Microtomographic techniques are widely used for studying the trabecular architectures in the orthopedics and elucidation of tooth micromorphology in the field of dentistry. Its application to assess the osseointegration of dental implants has been studied as a non-invasive method, contrary to several conventional methods. The aim of this study is to evaluate the possibility of microtomography as a tool for assessing osseointegration. Twenty-four titanium dental implants (3.75 mm in diameter and 7 mm in total length) were installed in the tibia of New Zealand white rabbits, and retrieved with the surrounding bone after 3 months. The specimens were analyzed by three-dimensional microtomogram images (Skyscan 1074) and compared with the conventional histomorphography. The correlation coefficient was found to be 0.855, which means the two data sources are significantly correlated statistically. To predict the histomorphometric data using microtomographic data, a linear regression model was applied. These results showed some promise of using microtomograms for non-invasive osseointegration assessment if the methods can be calibrated more precisely by further study.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15777324     DOI: 10.1111/j.1600-0501.2004.01083.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  10 in total

1.  Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.

Authors:  Matthew J Meagher; Rachna N Parwani; Amarjit S Virdi; Dale R Sumner
Journal:  J Orthop Res       Date:  2017-10-04       Impact factor: 3.494

2.  Evaluation of bone response to titanium-coated polymethyl methacrylate resin (PMMA) implants by X-ray tomography.

Authors:  Manal M Shalabi; Johannes G C Wolke; Vincent M J I Cuijpers; John A Jansen
Journal:  J Mater Sci Mater Med       Date:  2007-06-09       Impact factor: 3.896

3.  How precise is dental volumetric tomography in the prediction of bone density?

Authors:  Hakan Bilhan; Selda Arat; Onur Geckili
Journal:  Int J Dent       Date:  2012-05-30

4.  Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

Authors:  Sung-Won Kang; Woo-Jin Lee; Soon-Chul Choi; Sam-Sun Lee; Min-Suk Heo; Kyung-Hoe Huh; Tae-Il Kim; Won-Jin Yi
Journal:  Imaging Sci Dent       Date:  2015-03-13

5.  A correlative imaging based methodology for accurate quantitative assessment of bone formation in additive manufactured implants.

Authors:  Hua Geng; Naomi M Todd; Aine Devlin-Mullin; Gowsihan Poologasundarampillai; Taek Bo Kim; Kamel Madi; Sarah Cartmell; Christopher A Mitchell; Julian R Jones; Peter D Lee
Journal:  J Mater Sci Mater Med       Date:  2016-05-06       Impact factor: 3.896

6.  Accuracy of different electronic torque drivers: A comparative evaluation.

Authors:  Byeong-Dae Ko; KeunBaDa Son; Seok Hyon Kang; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2019-12-18       Impact factor: 1.904

Review 7.  Bioactive Surfaces vs. Conventional Surfaces in Titanium Dental Implants: A Comparative Systematic Review.

Authors:  Nansi López-Valverde; Javier Flores-Fraile; Juan Manuel Ramírez; Bruno Macedo de Sousa; Silvia Herrero-Hernández; Antonio López-Valverde
Journal:  J Clin Med       Date:  2020-06-29       Impact factor: 4.241

8.  Effect of platelet-rich and platelet-poor plasma on 3D bone-to-implant contact: a preclinical micro-CT study.

Authors:  Dandan Song; Sohaib Shujaat; Yan Huang; Jeroen Van Dessel; Constantinus Politis; Ivo Lambrichts; Reinhilde Jacobs
Journal:  Int J Implant Dent       Date:  2021-02-18

9.  Comparison of three-dimensional digital analyses and two-dimensional histomorphometric analyses of the bone-implant interface.

Authors:  Jeong-Min Hong; Ung-Gyu Kim; In-Sung Luke Yeo
Journal:  PLoS One       Date:  2022-10-14       Impact factor: 3.752

10.  Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography.

Authors:  Jung-Yoo Chesaria Choi; Cham Albert Choi; In-Sung Luke Yeo
Journal:  J Periodontal Implant Sci       Date:  2018-08-29       Impact factor: 2.614

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.