Literature DB >> 15375777

Comparison of microfocus- and synchrotron X-ray tomography for the analysis of osteointegration around Ti6Al4V implants.

R Bernhardt1, D Scharnweber, B Müller, P Thurner, H Schliephake, P Wyss, F Beckmann, J Goebbels, H Worch.   

Abstract

Micro-computed tomography (microCT) provides quantitative three-dimensional information of bone around titanium implants similar to classical histology. The study, based on an animal model, containing cuboid-shaped biofunctionalised Ti6Al4V implants with surrounding bone after 4 weeks, is performed using 3 microCT-systems with X-ray tubes, one synchrotron-radiation-based microCT-system (SRmicroCT), and classical histology. Although the spatial resolution of the microCT-systems is comparable, only the results of SRmicroCT agree with results of classical histology. The X-ray tube sources give rise to huge artefacts in the tomograms (interface scattering, beam hardening), which impaired the quantitative analysis of bone up to about 200microm from the implant surface. Due to the non-destructive character of microCT the specimens can be subsequently examined by classical histology without restriction. The quantitative comparison of bone formation uncovers the strong dependence of the newly formed bone from the selected slice. This implies the necessity of 3D analysis. SRmicroCT and classical histology prove that surface modifications of the titanium implant significantly influence the bone formation. Using SRmicroCT, the preparation artefacts due to cutting and polishing are excluded.

Mesh:

Substances:

Year:  2004        PMID: 15375777     DOI: 10.22203/ecm.v007a05

Source DB:  PubMed          Journal:  Eur Cell Mater        ISSN: 1473-2262            Impact factor:   3.942


  13 in total

Review 1.  Application of polychromatic µCT for mineral density determination.

Authors:  W Zou; N Hunter; M V Swain
Journal:  J Dent Res       Date:  2010-09-21       Impact factor: 6.116

2.  Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis.

Authors:  He-Kyong Kang; Tien-Min Chu; Paul Dechow; Kelton Stewart; Hee-Moon Kyung; Sean Shih-Yao Liu
Journal:  Eur J Orthod       Date:  2015-04-23       Impact factor: 3.075

3.  Direct visualization and quantification of bone growth into porous titanium implants using micro computed tomography.

Authors:  E Baril; L P Lefebvre; S A Hacking
Journal:  J Mater Sci Mater Med       Date:  2011-04-22       Impact factor: 3.896

Review 4.  Evaluation of bone scaffolds by micro-CT.

Authors:  F Peyrin
Journal:  Osteoporos Int       Date:  2011-06       Impact factor: 4.507

5.  Radio-opaque polyethylene for personalized craniomaxillofacial implants.

Authors:  Marcin Kozakiewicz; Leszek Olbrzymek; Ludomir Stefanczyk; Marek Olszycki; Piotr Komorowski; Bogdan Walkowiak; Bartłomiej Konieczny; Michał Krasowski; Jerzy Sokołowski
Journal:  Clin Oral Investig       Date:  2016-10-20       Impact factor: 3.573

6.  Three-dimensional visualization of bioactive glass-bone integration in a rabbit tibia model using synchrotron X-ray microcomputed tomography.

Authors:  Qiang Fu; Wenhai Huang; Weitao Jia; Mohamed N Rahaman; Xin Liu; Antoni P Tomsia
Journal:  Tissue Eng Part A       Date:  2011-08-29       Impact factor: 3.845

7.  Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Authors:  Jeffrey A Meganck; Kenneth M Kozloff; Michael M Thornton; Stephen M Broski; Steven A Goldstein
Journal:  Bone       Date:  2009-08-06       Impact factor: 4.398

8.  Imaging challenges in biomaterials and tissue engineering.

Authors:  Alyssa A Appel; Mark A Anastasio; Jeffery C Larson; Eric M Brey
Journal:  Biomaterials       Date:  2013-06-13       Impact factor: 12.479

9.  Evaluation of bone response to titanium-coated polymethyl methacrylate resin (PMMA) implants by X-ray tomography.

Authors:  Manal M Shalabi; Johannes G C Wolke; Vincent M J I Cuijpers; John A Jansen
Journal:  J Mater Sci Mater Med       Date:  2007-06-09       Impact factor: 3.896

10.  Going beyond histology. Synchrotron micro-computed tomography as a methodology for biological tissue characterization: from tissue morphology to individual cells.

Authors:  Rolf Zehbe; Astrid Haibel; Heinrich Riesemeier; Ulrich Gross; C James Kirkpatrick; Helmut Schubert; Christoph Brochhausen
Journal:  J R Soc Interface       Date:  2009-03-25       Impact factor: 4.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.