Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT.

T G Flohr1, K Stierstorfer, C Süss, B Schmidt, A N Primak, C H McCollough.   

Abstract

We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32 x 0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution.

Mesh:

Year:  2007        PMID: 17555253     DOI: 10.1118/1.2722872

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

Review 1.  Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology.

Authors:  Shuai Leng; Michael Bruesewitz; Shengzhen Tao; Kishore Rajendran; Ahmed F Halaweish; Norbert G Campeau; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiographics       Date:  2019 May-Jun       Impact factor: 5.333

2.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system.

Authors:  Shuai Leng; Zhicong Yu; Ahmed Halaweish; Steffen Kappler; Katharina Hahn; Andre Henning; Zhoubo Li; John Lane; David L Levin; Steven Jorgensen; Erik Ritman; Cynthia McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-22

3.  150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images.

Authors:  Shuai Leng; Kishore Rajendran; Hao Gong; Wei Zhou; Ahmed F Halaweish; Andre Henning; Steffen Kappler; Matthias Baer; Joel G Fletcher; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2018-11       Impact factor: 6.016

4.  Temporal Bone CT: Improved Image Quality and Potential for Decreased Radiation Dose Using an Ultra-High-Resolution Scan Mode with an Iterative Reconstruction Algorithm.

Authors:  S Leng; F E Diehn; J I Lane; K K Koeller; R J Witte; R E Carter; C H McCollough
Journal:  AJNR Am J Neuroradiol       Date:  2015-05-21       Impact factor: 3.825

5.  Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study.

Authors:  W Zhou; J I Lane; M L Carlson; M R Bruesewitz; R J Witte; K K Koeller; L J Eckel; R E Carter; C H McCollough; S Leng
Journal:  AJNR Am J Neuroradiol       Date:  2018-08-09       Impact factor: 3.825

6.  X-ray deconvolution microscopy.

Authors:  Sebastian Ehn; Franz Michael Epple; Andreas Fehringer; David Pennicard; Heinz Graafsma; Peter Noël; Franz Pfeiffer
Journal:  Biomed Opt Express       Date:  2016-03-09       Impact factor: 3.732

7.  Renal Stone Characterization using High Resolution Imaging Mode on a Photon Counting Detector CT System.

Authors:  A Ferrero; R Gutjahr; A Henning; S Kappler; A Halaweish; D Abdurakhimova; Z Peterson; J Montoya; S Leng; C McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-02-11

8.  Harmonization of in-plane resolution in CT using multiple reconstructions from single acquisitions.

Authors:  Gonzalo Vegas-Sánchez-Ferrero; Gabriel Ramos-Llordén; Raúl San José Estépar
Journal:  Med Phys       Date:  2021-09-14       Impact factor: 4.071

9.  A High-Resolution Imaging Technique using a Whole-body, Research Photon Counting Detector CT System.

Authors:  S Leng; Z Yu; A Halaweish; S Kappler; K Hahn; A Henning; Z Li; J Lane; D L Levin; S Jorgensen; E Ritman; C McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-03

10.  Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging.

Authors:  Mathias Meyer; Holger Haubenreisser; Rainer Raupach; Bernhard Schmidt; Florian Lietzmann; Christianne Leidecker; Thomas Allmendinger; Thomas Flohr; Lothar R Schad; Stefan O Schoenberg; Thomas Henzler
Journal:  Eur Radiol       Date:  2014-09-08       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.