Literature DB >> 11230897

An improved breast irradiation technique using three-dimensional geometrical information and intensity modulation.

B van Asselen1, C P Raaijmakers, P Hofman, J J Lagendijk.   

Abstract

BACKGROUND AND
PURPOSE: In spite of the complex geometry of the breast, treatment planning for tangential breast irradiation is conventionally performed using two-dimensional patient anatomy information. The purpose of this work was to develop a new technique which takes the three-dimensional (3D) patient geometry into account.
MATERIALS AND METHODS: An intensity-modulated radiotherapy (IMRT) technique was developed based on the division of the tangential fields in four multi-leaf collimator (MLC) shaped segments. The shape of these segments was obtained from an equivalent path length map of the irradiated volume. Approximately 88% of the dose was delivered by two open fields covering the whole treated volume. Dose calculations for the IMRT technique and the conventional technique were performed for five patients, using computer tomography (CT) data and a 3D calculation algorithm. A planning target volume (PTV) and ipsilateral lung volume were delineated in these CT data.
RESULTS: All patients showed similar equivalent path length patterns. Analysis of the dose distribution showed an improved dose distribution using the IMRT technique. The dose inhomogeneity in the PTV was 9.0% (range 6.4-11.4%) for the conventional and 7.6% (range 6.5-10.3%) for the IMRT technique. The mean lung dose was reduced for the IMRT technique by approximately 10% compared with the conventional technique.
CONCLUSION: A new breast irradiation technique has been developed which improves the dose homogeneity within the planning target volume and reduces the dose to the lung. Furthermore, the IMRT technique creates the possibility to improve the field matching in case of multiple field irradiations of the breast and lymph nodes.

Entities:  

Mesh:

Year:  2001        PMID: 11230897     DOI: 10.1016/s0167-8140(00)00278-4

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  13 in total

1.  Assessment of setup accuracy in patients receiving postmastectomy radiotherapy using electronic portal imaging.

Authors:  Funda Gul Koseoglu; Nina Tuncel; Adem Unal Kizildag; Melahat Garipagaoglu; Mustafa Adli; Cagatay Andic
Journal:  Radiat Med       Date:  2007-02-27

2.  Irregular surface compensation for radiotherapy of the breast: correlating depth of the compensation surface with breast size and resultant dose distribution.

Authors:  D J Emmens; H V James
Journal:  Br J Radiol       Date:  2009-09-14       Impact factor: 3.039

3.  Effect of breathing motion in radiotherapy of breast cancer: 4D dose calculation and motion tracking via EPID.

Authors:  Anne Richter; Reinhard Sweeney; Kurt Baier; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2009-08-28       Impact factor: 3.621

4.  Variability of target and normal structure delineation for breast cancer radiotherapy: an RTOG Multi-Institutional and Multiobserver Study.

Authors:  X Allen Li; An Tai; Douglas W Arthur; Thomas A Buchholz; Shannon Macdonald; Lawrence B Marks; Jean M Moran; Lori J Pierce; Rachel Rabinovitch; Alphonse Taghian; Frank Vicini; Wendy Woodward; Julia R White
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-01       Impact factor: 7.038

5.  Comparison of dose distributions and organs at risk (OAR) doses in conventional tangential technique (CTT) and IMRT plans with different numbers of beam in left-sided breast cancer.

Authors:  Hande Bas Ayata; Metin Güden; Cemile Ceylan; Nadir Kücük; Kayihan Engin
Journal:  Rep Pract Oncol Radiother       Date:  2011-04-08

6.  Intensity modulated radiotherapy: advantages, limitations and future developments.

Authors:  Ky Cheung
Journal:  Biomed Imaging Interv J       Date:  2006-01-01

7.  Comparison of breast simultaneous integrated boost (SIB) radiotherapy techniques.

Authors:  Moamen M O M Aly; Gerhard Glatting; Lennart Jahnke; Frederik Wenz; Yasser Abo-Madyan
Journal:  Radiat Oncol       Date:  2015-07-09       Impact factor: 3.481

8.  Tangential intensity modulated radiation therapy (IMRT) to the intact breast.

Authors:  Jenna Dean; Carmen J Hansen; Justin Westhuyzen; Brett Waller; Kirsty Turnbull; Maree Wood; Andrew Last
Journal:  J Med Radiat Sci       Date:  2016-07-18

9.  HDR brachytherapy combined with 3-D conformal vs. IMRT in left-sided breast cancer patients including internal mammary chain: comparative analysis of dosimetric and technical parameters.

Authors:  Rajesh Ashok Kinhikar; Sudesh Sharad Deshpande; Umesh Mahantshetty; Rajiv Sarin; Shyam Kishore Shrivastava; Deepak Dattatraya Deshpande
Journal:  J Appl Clin Med Phys       Date:  2005-08-12       Impact factor: 2.102

10.  Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer.

Authors:  E M Donovan; H James; M Bonora; J R Yarnold; P M Evans
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.