Comparison of anterior chamber depth measurement between Orbscan IIz and ultrasound biomicroscopy.

Jong Yun Lee1, Jun-Heon Kim, Hyo-Myung Kim, Jong-Suk Song.   

Abstract

PURPOSE: To compare the measurement of anterior chamber depth exclusive of corneal thickness using Orbscan IIz and ultrasound biomicroscopy (UBM) and evaluate the repeatability of each method.
METHODS: Three consecutive measurements of anterior chamber depth were prospectively performed using Orbscan IIz and Paradigm 50-MHz UBM in 40 eyes in 20 individuals. Mean values were compared using the paired t test. For 12 eyes in 6 individuals, anterior chamber depth measurements were performed 5 times to estimate the repeatability of each method by a coefficient of variation. Refractive errors were measured to correlate with anterior chamber depth.
RESULTS: The mean anterior chamber depth was 2.82 +/- 0.46 mm with the Orbscan IIz and 2.91 +/- 0.43 mm in UBM. This difference was statistically significant (P < .001), but not clinically meaningful. The coefficient of variation was 1.15% and 1.10% in Orbscan IIz and UBM, respectively. A negative correlation between anterior chamber depth and spherical equivalent refraction was noted within the range of -5.50 to +3.00 diopters.
CONCLUSIONS: The mean anterior chamber depth of Orbscan IIz was 0.087 mm less than that of UBM. Both methods were precise. Orbscan IIz seems to be a useful and more convenient method to measure anterior chamber depth for phakic intraocular lens implantation.

Entities:  

Mesh:

Year:  2007        PMID: 17523511     DOI: 10.3928/1081-597X-20070501-12

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  6 in total

1.  Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery.

Authors:  Jumpei Matsuda; Osamu Hieda; Shigeru Kinoshita
Journal:  Jpn J Ophthalmol       Date:  2008-09-05       Impact factor: 2.447

Review 2.  Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review.

Authors:  Alberto Domínguez-Vicent; Cari Pérez-Vives; Teresa Ferrer-Blasco; Santiago García-Lázaro; Robert Montés-Micó
Journal:  Int J Ophthalmol       Date:  2016-07-18       Impact factor: 1.779

3.  Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth.

Authors:  Haya Matuoq Al Farhan
Journal:  BMC Ophthalmol       Date:  2014-02-25       Impact factor: 2.209

4.  Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography.

Authors:  Onur Polat; Zeki Baysal; Serkan Özcan; Sibel İnan; Ümit Übeyt İnan
Journal:  Turk J Ophthalmol       Date:  2016-12-01

5.  Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery.

Authors:  Ali Simsek; Süleyman Ciftci
Journal:  Clin Ophthalmol       Date:  2012-11-21

6.  Anterior segment biometry using ultrasound biomicroscopy and the Artemis-2 very high frequency ultrasound scanner.

Authors:  Haya M Al-Farhan; Reem N Almutairi
Journal:  Clin Ophthalmol       Date:  2013-01-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.