Literature DB >> 17512752

Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures.

Erin Shammel Baker1, Brian H Clowers, Fumin Li, Keqi Tang, Aleksey V Tolmachev, David C Prior, Mikhail E Belov, Richard D Smith.   

Abstract

The ability of ion mobility spectrometry coupled with mass spectrometry (IMS-MS) to characterize biological mixtures has been illustrated over the past eight years. However, the challenges posed by the extreme complexity of many biological samples have demonstrated the need for higher resolution IMS-MS measurements. We have developed a higher resolution ESI-IMS-TOF MS by utilizing high-pressure electrodynamic ion funnels at both ends of the IMS drift cell and operating the drift cell at an elevated pressure compared with that conventionally used. The ESI-IMS-TOF MS instrument consists of an ESI source, an hourglass ion funnel used for ion accumulation/injection into an 88 cm drift cell, followed by a 10 cm ion funnel and a commercial orthogonal time-of-flight mass spectrometer providing high mass measurement accuracy. It was found that the rear ion funnel could be effectively operated as an extension of the drift cell when the DC fields were matched, providing an effective drift region of 98 cm. The resolution of the instrument was evaluated at pressures ranging from 4 to 12 torr and ion mobility drift voltages of 16 V/cm (4 torr) to 43 V/cm (12 torr). An increase in resolution from 55 to 80 was observed from 4 to 12 torr nitrogen drift gas with no significant loss in sensitivity. The choice of drift gas was also shown to influence the degree of ion heating and relative trapping efficiency within the ion funnel.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17512752      PMCID: PMC3292285          DOI: 10.1016/j.jasms.2007.03.031

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  23 in total

1.  Charge capacity limitations of radio frequency ion guides in their use for improved ion accumulation and trapping in mass spectrometry.

Authors:  A V Tolmachev; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2000-03-01       Impact factor: 6.986

2.  Radial stratification of ions as a function of mass to charge ratio in collisional cooling radio frequency multipoles used as ion guides or ion traps.

Authors:  A V Tolmachev; H R Udseth; R D Smith
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

3.  High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics.

Authors:  Yufeng Shen; Rui Zhao; Scott J Berger; Gordon A Anderson; Nestor Rodriguez; Richard D Smith
Journal:  Anal Chem       Date:  2002-08-15       Impact factor: 6.986

4.  An IMS-IMS analogue of MS-MS.

Authors:  Stormy L Koeniger; Samuel I Merenbloom; Stephen J Valentine; Martin F Jarrold; Harold R Udseth; Richard D Smith; David E Clemmer
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

5.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Quanzhou Luo; Ronald J Moore; Daniel J Orton; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

6.  Evaluation of multidimensional chromatography coupled with tandem mass spectrometry (LC/LC-MS/MS) for large-scale protein analysis: the yeast proteome.

Authors:  Junmin Peng; Joshua E Elias; Carson C Thoreen; Larry J Licklider; Steven P Gygi
Journal:  J Proteome Res       Date:  2003 Jan-Feb       Impact factor: 4.466

7.  ESI/ion trap/ion mobility/time-of-flight mass spectrometry for rapid and sensitive analysis of biomolecular mixtures.

Authors:  S C Henderson; S J Valentine; A E Counterman; D E Clemmer
Journal:  Anal Chem       Date:  1999-01-15       Impact factor: 6.986

8.  Gas-phase separations of protease digests.

Authors:  S J Valentine; A E Counterman; C S Hoaglund; J P Reilly; D E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  1998-11       Impact factor: 3.109

9.  Application of peptide LC retention time information in a discriminant function for peptide identification by tandem mass spectrometry.

Authors:  Eric F Strittmatter; Lars J Kangas; Konstantinos Petritis; Heather M Mottaz; Gordon A Anderson; Yufeng Shen; Jon M Jacobs; David G Camp; Richard D Smith
Journal:  J Proteome Res       Date:  2004 Jul-Aug       Impact factor: 4.466

10.  Gas-phase ion chromatography: transition metal state selection and carbon cluster formation.

Authors:  M T Bowers; P R Kemper; G von Helden; P A van Koppen
Journal:  Science       Date:  1993-06-04       Impact factor: 47.728

View more
  64 in total

1.  Accelerated high-resolution differential ion mobility separations using hydrogen.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  Anal Chem       Date:  2011-11-10       Impact factor: 6.986

2.  The interface between biomarker discovery and clinical validation: The tar pit of the protein biomarker pipeline.

Authors:  Amanda G Paulovich; Jeffrey R Whiteaker; Andrew N Hoofnagle; Pei Wang
Journal:  Proteomics Clin Appl       Date:  2008-10-01       Impact factor: 3.494

3.  Conformational distribution of bradykinin [bk + 2 H]2+ revealed by cold ion spectroscopy coupled with FAIMS.

Authors:  Georgios Papadopoulos; Annette Svendsen; Oleg V Boyarkin; Thomas R Rizzo
Journal:  J Am Soc Mass Spectrom       Date:  2012-04-18       Impact factor: 3.109

4.  Machine learning based prediction for peptide drift times in ion mobility spectrometry.

Authors:  Anuj R Shah; Khushbu Agarwal; Erin S Baker; Mudita Singhal; Anoop M Mayampurath; Yehia M Ibrahim; Lars J Kangas; Matthew E Monroe; Rui Zhao; Mikhail E Belov; Gordon A Anderson; Richard D Smith
Journal:  Bioinformatics       Date:  2010-05-21       Impact factor: 6.937

5.  Fundamentals of Trapped Ion Mobility Spectrometry Part II: Fluid Dynamics.

Authors:  Joshua A Silveira; Karsten Michelmann; Mark E Ridgeway; Melvin A Park
Journal:  J Am Soc Mass Spectrom       Date:  2016-02-10       Impact factor: 3.109

6.  New frontiers for mass spectrometry based upon structures for lossless ion manipulations.

Authors:  Yehia M Ibrahim; Ahmed M Hamid; Liulin Deng; Sandilya V B Garimella; Ian K Webb; Erin S Baker; Richard D Smith
Journal:  Analyst       Date:  2017-03-27       Impact factor: 4.616

7.  Pseudorandom sequence modifications for ion mobility orthogonal time-of-flight mass spectrometry.

Authors:  Brian H Clowers; Mikhail E Belov; David C Prior; William F Danielson; Yehia Ibrahim; Richard D Smith
Journal:  Anal Chem       Date:  2008-03-01       Impact factor: 6.986

8.  The fungal cultivar of leaf-cutter ants produces specific enzymes in response to different plant substrates.

Authors:  Lily Khadempour; Kristin E Burnum-Johnson; Erin S Baker; Carrie D Nicora; Bobbie-Jo M Webb-Robertson; Richard A White; Matthew E Monroe; Eric L Huang; Richard D Smith; Cameron R Currie
Journal:  Mol Ecol       Date:  2016-10-26       Impact factor: 6.185

9.  An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies.

Authors:  Erin Shammel Baker; Eric A Livesay; Daniel J Orton; Ronald J Moore; William F Danielson; David C Prior; Yehia M Ibrahim; Brian L LaMarche; Anoop M Mayampurath; Athena A Schepmoes; Derek F Hopkins; Keqi Tang; Richard D Smith; Mikhail E Belov
Journal:  J Proteome Res       Date:  2010-02-05       Impact factor: 4.466

10.  High-resolution differential ion mobility spectrometry of a protein.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  Anal Chem       Date:  2012-12-17       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.