Literature DB >> 12199598

High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics.

Yufeng Shen1, Rui Zhao, Scott J Berger, Gordon A Anderson, Nestor Rodriguez, Richard D Smith.   

Abstract

We describe high-efficiency (peak capacities of approximately 10(3)) nanoscale (using column inner diameters down to 15 microm) liquid chromatography (nanoLC)/low flow rate electrospray (nanoESI) mass spectrometry (MS) for the sensitive analysis of complex global cellular protein enzymatic digests (i.e., proteomics). Using a liquid slurry packing method with carefully selected packing solvents, 87-cm-length capillaries having inner diameters of 14.9-74.5 microm were successfully packed with 3-microm C18-bonded porous (300-A pores) silica particles at a pressure of 18,000 psi. With a mobile-phase delivery pressure of 10,000 psi, these packed capillaries provided mobile-phase flow rates as low as approximately 20 nL/min at LC linear velocities of approximately 0.2 cm/s, which is near optimal for separation efficiency. To maintain chromatographic efficiency, unions with internal channel diameters as small as 10 microm were specially produced for connecting packed capillaries to replaceable nanoESI emitters having orifice diameters of 2-10 microm (depending on the packed capillary dimensions). Coupled on-line with a hybrid-quadrupole time-of-flight MS through the nanoESI interface, the nanoLC separations provided peak capacities of approximately 10(3) for proteome proteolytic polypeptide mixtures when a positive feedback switching valve was used for quantitatively introducing samples. Over a relatively large range of sample loadings (e.g., 5-100 ng, and 50-500 ng of cellular proteolytic peptides for 14.9- and 29.7-microm-i.d. packed capillaries, respectively), the nanoLC/nanoESI MS response for low-abundance components of the complex mixtures was found to increase linearly with sample loading. The nanoLC/nanoESI-MS sensitivity also increased linearly with decreasing flow rate (or approximately inversely proportional to the square of the capillary inner diameter) in the flow range of 20-400 nL/min. Thus, except at the lower loadings, decreasing the separation capillary inner diameter has an effect equivalent to increasing sample loading, which is important for sample-limited proteomic applications. No significant effects on recovery of eluting polypeptides were observed using porous C18 particles with surface pores of 300-A versus nonporous particles. Tandem MS analyses were also demonstrated using the high-efficiency nanoLC separations. Chromatographic elution time, MS response intensity, and mass measurement accuracy was examined between runs with a single column (with a single nanoESI emitter), between different columns (same and different inner diameters with different nanoESI emitters), and for different samples (various concentrations of cellular proteolytic peptides) and demonstrated robust and reproducible sensitive analyses for complex proteomic samples.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12199598     DOI: 10.1021/ac0202280

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  75 in total

1.  An automated high performance capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometer for high-throughput proteomics.

Authors:  Mikhail E Belov; Gordon A Anderson; Mark A Wingerd; Harold R Udseth; Keqi Tang; David C Prior; Kenneth R Swanson; Michael A Buschbach; Eric F Strittmatter; Ronald J Moore; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2004-02       Impact factor: 3.109

Review 2.  Proteomics for nasal secretion analysis.

Authors:  Begoña Casado
Journal:  Curr Allergy Asthma Rep       Date:  2004-05       Impact factor: 4.806

3.  Modeling the resolution and sensitivity of FAIMS analyses.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2004-10       Impact factor: 3.109

4.  A new approach to high sensitivity liquid chromatography-mass spectrometry of peptides using nanoflow solvent assisted inlet ionization.

Authors:  Beixi Wang; Ellen D Inutan; Sarah Trimpin
Journal:  J Am Soc Mass Spectrom       Date:  2012-01-12       Impact factor: 3.109

5.  Nanospray FAIMS fractionation provides significant increases in proteome coverage of unfractionated complex protein digests.

Authors:  Kristian E Swearingen; Michael R Hoopmann; Richard S Johnson; Ramsey A Saleem; John D Aitchison; Robert L Moritz
Journal:  Mol Cell Proteomics       Date:  2011-12-20       Impact factor: 5.911

6.  Analysis of protein mixtures from whole-cell extracts by single-run nanoLC-MS/MS using ultralong gradients.

Authors:  Thomas Köcher; Peter Pichler; Remco Swart; Karl Mechtler
Journal:  Nat Protoc       Date:  2012-04-12       Impact factor: 13.491

7.  A study of electrospray ionization emitters with differing geometries with respect to flow rate and electrospray voltage.

Authors:  Brent R Reschke; Aaron T Timperman
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-12       Impact factor: 3.109

Review 8.  New mass spectrometry technologies contributing towards comprehensive and high throughput omics analyses of single cells.

Authors:  Sneha P Couvillion; Ying Zhu; Gabe Nagy; Joshua N Adkins; Charles Ansong; Ryan S Renslow; Paul D Piehowski; Yehia M Ibrahim; Ryan T Kelly; Thomas O Metz
Journal:  Analyst       Date:  2019-01-28       Impact factor: 4.616

9.  Potential of poly(styrene-co-divinylbenzene) monolithic columns for the LC-MS analysis of protein digests.

Authors:  Michiel H M van de Meent; Sebastiaan Eeltink; Gerhardus J de Jong
Journal:  Anal Bioanal Chem       Date:  2010-12-24       Impact factor: 4.142

10.  Optimization of the design and operation of FAIMS analyzers.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-01       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.