Literature DB >> 17505872

Incorporation of a Laguerre-Gauss channelized Hotelling observer for false-positive reduction in a mammographic mass CAD system.

Alan H Baydush1, David M Catarious, Joseph Y Lo, Carey E Floyd.   

Abstract

Previously, we developed a simple Laguerre-Gauss (LG) channelized Hotelling observer (CHO) for incorporation into our mass computer-aided detection (CAD) system. This LG-CHO was trained using initial detection suspicious region data and was empirically optimized for free parameters. For the study presented in this paper, we wish to create a more optimal mass detection observer based on a novel combination of LG channels. A large set of LG channels with differing free parameters was created. Each of these channels was applied to the suspicious regions, and an output test statistic was determined. A stepwise feature selection algorithm was used to determine which LG channels would combine best to detect masses. These channels were combined using a HO to create a single template for the mass CAD system. Results from free-response receiver operating characteristic curves demonstrated that the incorporation of the novel LG-CHO into the CAD system slightly improved performance in high-sensitivity regions.

Entities:  

Mesh:

Year:  2007        PMID: 17505872      PMCID: PMC3043903          DOI: 10.1007/s10278-007-9009-8

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  8 in total

1.  Basic principles of ROC analysis.

Authors:  C E Metz
Journal:  Semin Nucl Med       Date:  1978-10       Impact factor: 4.446

2.  Incorporation of an iterative, linear segmentation routine into a mammographic mass CAD system.

Authors:  David M Catarious; Alan H Baydush; Carey E Floyd
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

3.  Characterization of difference of Gaussian filters in the detection of mammographic regions.

Authors:  David M Catarious; Alan H Baydush; Carey E Floyd
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

Review 4.  ROC methodology in radiologic imaging.

Authors:  C E Metz
Journal:  Invest Radiol       Date:  1986-09       Impact factor: 6.016

5.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

6.  Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center.

Authors:  T W Freer; M J Ulissey
Journal:  Radiology       Date:  2001-09       Impact factor: 11.105

7.  Hotelling trace criterion and its correlation with human-observer performance.

Authors:  R D Fiete; H H Barrett; W E Smith; K J Myers
Journal:  J Opt Soc Am A       Date:  1987-05       Impact factor: 2.129

8.  Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging.

Authors:  H C Gifford; M A King; D J de Vries; E J Soares
Journal:  J Nucl Med       Date:  2000-03       Impact factor: 10.057

  8 in total
  2 in total

1.  A modified undecimated discrete wavelet transform based approach to mammographic image denoising.

Authors:  Eri Matsuyama; Du-Yih Tsai; Yongbum Lee; Masaki Tsurumaki; Noriyuki Takahashi; Haruyuki Watanabe; Hsian-Min Chen
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

Review 2.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.