Literature DB >> 15259655

Incorporation of an iterative, linear segmentation routine into a mammographic mass CAD system.

David M Catarious1, Alan H Baydush, Carey E Floyd.   

Abstract

In previous research, we have developed a computer-aided detection (CAD) system designed to detect masses in mammograms. The previous version of our system employed a simple but imprecise method to localize the masses. In this research, we present a more robust segmentation routine for use with mammographic masses. Our hypothesis is that by more accurately describing the morphology of the masses, we can improve the CAD system's ability to distinguish masses from other mammographic structures. To test this hypothesis, we incorporated the new segmentation routine into our CAD system and examined the change in performance. The developed iterative, linear segmentation routine is a gray level-based procedure. Using the identified regions from the previous CAD system as the initial seeds, the new segmentation algorithm refines the suspicious mass borders by making estimates of the interior and exterior pixels. These estimates are then passed to a linear discriminant, which determines the optimal threshold between the interior and exterior pixels. After applying the threshold and identifying the object's outline, two constraints on the border are applied to reduce the influence of background noise. After the border is constrained, the process repeats until a stopping criterion is reached. The segmentation routine was tested on a study database of 183 mammographic images extracted from the Digital Database for Screening Mammography. Eighty-three of the images contained 50 malignant and 50 benign masses; 100 images contained no masses. The previously developed CAD system was used to locate a set of suspicious regions of interest (ROIs) within the images. To assess the performance of the segmentation algorithm, a set of 20 features was measured from the suspicious regions before and after the application of the developed segmentation routine. Receiver operating characteristic (ROC) analysis was employed on the ROIs to examine the discriminatory capabilities of each individual feature before and after the segmentation routine. A statistically significant performance increase was found in many of the individual features, particularly those describing the mass borders. To examine how the incorporation of the segmentation routine affected the performance of the overall CAD system, free-response ROC (FROC) analysis was employed. When considering only malignant masses, the FROC performance of the system with the segmentation routine appeared better than the previous system. When detecting 90% of the malignant masses, the previous system achieved 4.9 false positives per image (FPpI) compared to the post-segmentation system's 4.2 FPpI. At 80% sensitivity, the respective FPpI were 3.5 and 1.6.

Mesh:

Year:  2004        PMID: 15259655     DOI: 10.1118/1.1738960

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Reliable evaluation of performance level for computer-aided diagnostic scheme.

Authors:  Qiang Li
Journal:  Acad Radiol       Date:  2007-08       Impact factor: 3.173

2.  Incorporation of a Laguerre-Gauss channelized Hotelling observer for false-positive reduction in a mammographic mass CAD system.

Authors:  Alan H Baydush; David M Catarious; Joseph Y Lo; Carey E Floyd
Journal:  J Digit Imaging       Date:  2007-02-16       Impact factor: 4.056

Review 3.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach.

Authors:  Swatee Singh; Georgia D Tourassi; Jay A Baker; Ehsan Samei; Joseph Y Lo
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  Evaluating the effect of image preprocessing on an information-theoretic CAD system in mammography.

Authors:  Georgia D Tourassi; Robert Ike; Swatee Singh; Brian Harrawood
Journal:  Acad Radiol       Date:  2008-05       Impact factor: 3.173

Review 6.  Needs assessment for next generation computer-aided mammography reference image databases and evaluation studies.

Authors:  Alexander Horsch; Alexander Hapfelmeier; Matthias Elter
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-03-30       Impact factor: 2.924

7.  Mutual information-based template matching scheme for detection of breast masses: from mammography to digital breast tomosynthesis.

Authors:  Maciej A Mazurowski; Joseph Y Lo; Brian P Harrawood; Georgia D Tourassi
Journal:  J Biomed Inform       Date:  2011-05-01       Impact factor: 6.317

8.  Selection of examples in case-based computer-aided decision systems.

Authors:  Maciej A Mazurowski; Jacek M Zurada; Georgia D Tourassi
Journal:  Phys Med Biol       Date:  2008-10-14       Impact factor: 3.609

Review 9.  Advances in computer-aided diagnosis for breast cancer.

Authors:  Lubomir Hadjiiski; Berkman Sahiner; Heang-Ping Chan
Journal:  Curr Opin Obstet Gynecol       Date:  2006-02       Impact factor: 1.927

10.  Automated detection of breast mass spiculation levels and evaluation of scheme performance.

Authors:  Luan Jiang; Enmin Song; Xiangyang Xu; Guangzhi Ma; Bin Zheng
Journal:  Acad Radiol       Date:  2008-12       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.