Literature DB >> 17153390

Characterization of difference of Gaussian filters in the detection of mammographic regions.

David M Catarious1, Alan H Baydush, Carey E Floyd.   

Abstract

In this article, we present a characterization of the effect of difference of Gaussians (DoG) filters in the detection of mammographic regions. DoG filters have been used previously in mammographic mass computer-aided detection (CAD) systems. As DoG filters are constructed from the subtraction of two bivariate Gaussian distributions, they require the specification of three parameters: the size of the filter template and the standard deviations of the constituent Gaussians. The influence of these three parameters in the detection of mammographic masses has not been characterized. In this work, we aim to determine how the parameters affect (1) the physical descriptors of the detected regions, (2) the true and false positive rates, and (3) the classification performance of the individual descriptors. To this end, 30 DoG filters are created from the combination of three template sizes and four values for each of the Gaussians' standard deviations. The filters are used to detect regions in a study database of 181 craniocaudal-view mammograms extracted from the Digital Database for Screening Mammography. To describe the physical characteristics of the identified regions, morphological and textural features are extracted from each of the detected regions. Differences in the mean values of the features caused by altering the DoG parameters are examined through statistical and empirical comparisons. The parameters' effects on the true and false positive rate are determined by examining the mean malignant sensitivities and false positives per image (FPpI). Finally, the effect on the classification performance is described by examining the variation in FPpI at the point where 81% of the malignant masses in the study database are detected. Overall, the findings of the study indicate that increasing the standard deviations of the Gaussians used to construct a DoG filter results in a dramatic decrease in the number of regions identified at the expense of missing a small number of malignancies. The sharp reduction in the number of identified regions allowed the identification of textural differences between large and small mammographic regions. We find that the classification performances of the features that achieve the lowest average FPpI are influenced by all three of the parameters.

Entities:  

Mesh:

Year:  2006        PMID: 17153390     DOI: 10.1118/1.2358326

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Incorporation of a Laguerre-Gauss channelized Hotelling observer for false-positive reduction in a mammographic mass CAD system.

Authors:  Alan H Baydush; David M Catarious; Joseph Y Lo; Carey E Floyd
Journal:  J Digit Imaging       Date:  2007-02-16       Impact factor: 4.056

2.  Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme.

Authors:  Maxine Tan; Jiantao Pu; Bin Zheng
Journal:  Phys Med Biol       Date:  2014-07-17       Impact factor: 3.609

Review 3.  Needs assessment for next generation computer-aided mammography reference image databases and evaluation studies.

Authors:  Alexander Horsch; Alexander Hapfelmeier; Matthias Elter
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-03-30       Impact factor: 2.924

4.  Assessment of global and local region-based bilateral mammographic feature asymmetry to predict short-term breast cancer risk.

Authors:  Yane Li; Ming Fan; Hu Cheng; Peng Zhang; Bin Zheng; Lihua Li
Journal:  Phys Med Biol       Date:  2018-01-09       Impact factor: 3.609

5.  An Efficient Approach for Automated Mass Segmentation and Classification in Mammograms.

Authors:  Min Dong; Xiangyu Lu; Yide Ma; Yanan Guo; Yurun Ma; Keju Wang
Journal:  J Digit Imaging       Date:  2015-10       Impact factor: 4.056

6.  Prediction of Short-Term Breast Cancer Risk with Fusion of CC- and MLO-Based Risk Models in Four-View Mammograms.

Authors:  Yane Li; Wei Yuan; Ming Fan; Bin Zheng; Lihua Li
Journal:  J Digit Imaging       Date:  2022-08       Impact factor: 4.903

7.  Towards optimized acquisition scheme for multiprojection correlation imaging of breast cancer.

Authors:  Amarpreet S Chawla; Robert S Saunders; Swatee Singh; Joseph Y Lo; Ehsan Samei
Journal:  Acad Radiol       Date:  2009-04       Impact factor: 3.173

8.  Species Identification of Food Contaminating Beetles by Recognizing Patterns in Microscopic Images of Elytra Fragments.

Authors:  Su Inn Park; Halil Bisgin; Hongjian Ding; Howard G Semey; Darryl A Langley; Weida Tong; Joshua Xu
Journal:  PLoS One       Date:  2016-06-24       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.