Literature DB >> 17505092

Dosimetry accuracy as a function of seed localization uncertainty in permanent prostate brachytherapy: increased seed number correlates with less variability in prostate dosimetry.

Yi Su1, Brian J Davis, Keith M Furutani, Michael G Herman, Richard A Robb.   

Abstract

The variation of permanent prostate brachytherapy dosimetry as a function of seed localization uncertainty was investigated for I-125 implants with seed activities commonly employed in contemporary practice. Post-implant imaging and radiation dosimetry data from nine patients who underwent permanent prostate brachytherapy served as the source of clinical data for this simulation study. Gaussian noise with standard deviations ranging from 0.5 to 10 mm was applied to the seed coordinates for each patient dataset and 1000 simulations were performed at each noise level. Dose parameters, including D90, were computed for each case and compared with the actual dosimetry data. A total of 81 000 complete sets of post-brachytherapy dose volume statistics were computed. The results demonstrated that less than 5% deviation of prostate D90 can be expected when the seed localization uncertainty is 2 mm, whereas a seed localization uncertainty of 10 mm yielded an average decrease in D90 of 33 Gy. The mean normalized decrement in the prostate V100 was 10% at 5 mm uncertainty. Implants with greater seed number and larger prostate volume correlated with less sensitivity of D90 and V100 to seed localization uncertainty. Estimated target volume dose parameters tended to decrease with increasing seed localization uncertainty. The bladder V100 varied more significantly both in mean and standard deviation as compared to the urethra V100. A larger number of implanted seeds also correlated to less sensitivity of the bladder V100 to seed localization uncertainty. In contrast, the deviation of urethra V100 did not correlate with the number of implanted seeds or prostate volume.

Entities:  

Mesh:

Year:  2007        PMID: 17505092     DOI: 10.1088/0031-9155/52/11/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy.

Authors:  Nathanael Kuo; Ehsan Dehghan; Anton Deguet; Omar Y Mian; Yi Le; E Clif Burdette; Gabor Fichtinger; Jerry L Prince; Danny Y Song; Junghoon Lee
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

3.  Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

Authors:  Ehsan Dehghan; Junghoon Lee; Pascal Fallavollita; Nathanael Kuo; Anton Deguet; Yi Le; E Clif Burdette; Danny Y Song; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Anal       Date:  2012-06-16       Impact factor: 8.545

4.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

5.  Point-to-volume registration of prostate implants to ultrasound.

Authors:  Ehsan Dehghan; Junghoon Lee; Pascal Fallavollita; Nathanael Kuo; Anton Deguet; E Clif Burdette; Danny Song; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

6.  Deformable registration of X-ray to MRI for post-implant dosimetry in prostate brachytherapy.

Authors:  Seyoun Park; Danny Y Song; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-18

7.  Permanent seed implant brachytherapy in low-risk prostate cancer: Preoperative planning with 145 Gy versus real-time intraoperative planning with 160 Gy.

Authors:  Olga Pons-Llanas; Susana Roldan-Ortega; Francisco Celada-Alvarez; María José Perez-Calatayud; Victoria Fornes-Ferrer; Alejandro Tormo-Micó; José Perez-Calatayud; José Luis López-Torrecilla
Journal:  Rep Pract Oncol Radiother       Date:  2018-07-26

Review 8.  Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM.

Authors:  Christian Kirisits; Mark J Rivard; Dimos Baltas; Facundo Ballester; Marisol De Brabandere; Rob van der Laarse; Yury Niatsetski; Panagiotis Papagiannis; Taran Paulsen Hellebust; Jose Perez-Calatayud; Kari Tanderup; Jack L M Venselaar; Frank-André Siebert
Journal:  Radiother Oncol       Date:  2013-11-30       Impact factor: 6.280

  8 in total