Literature DB >> 17504854

The effect of contact lens induced oedema on the accuracy of Goldmann tonometry in a mature population.

K Hamilton1, D Pye, S Hua, F Yu, J Chung, Q Hou.   

Abstract

AIM: To determine the effect of contact lens induced oedema on the accuracy of Goldmann tonometry measurements of intraocular pressure (IOP) in mature subjects.
METHODS: 22 healthy subjects aged between 50 and 60 years were recruited. Corneal curvature, IOP, and central corneal thickness (CCT) were measured before and after two hours of monocular closed eye wear of a thick hydroxyethyl methacrylate (HEMA) contact lens. Measurements were then repeated at 20 minute intervals for one hour after lens removal.
RESULTS: Both CCT (+54.1 mum) and IOP (+2.7 mm Hg) increased significantly after lens wear (p<0.001, paired t test with Bonferroni correction). For the hour following lens removal, the measured IOP was correlated to the increase in CCT (r = 0.84, p<0.001), at a rate of 1.0 mm Hg/10 mum (95% confidence interval, 0.8 to 1.2 mm Hg/10 mum, linear mixed model analysis).
CONCLUSIONS: A relatively small increase in CCT from contact lens induced corneal oedema caused an overestimation error in Goldmann tonometry measurements of IOP in healthy mature subjects.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17504854      PMCID: PMC2095538          DOI: 10.1136/bjo.2007.118695

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  36 in total

1.  Applanation tonometry and central corneal thickness.

Authors:  N Ehlers; T Bramsen; S Sperling
Journal:  Acta Ophthalmol (Copenh)       Date:  1975-03

2.  Etiology of corneal striae accompanying hydrogel lens wear.

Authors:  K A Polse; R B Mandell
Journal:  Invest Ophthalmol       Date:  1976-07

Review 3.  Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach.

Authors:  M J Doughty; M L Zaman
Journal:  Surv Ophthalmol       Date:  2000 Mar-Apr       Impact factor: 6.048

4.  Comparison of MacKay-Marg, Goldmann, and Perkins tonometers in abnormal corneas.

Authors:  F McMillan; R K Forster
Journal:  Arch Ophthalmol       Date:  1975-06

5.  Diurnal variations of corneal topography and thickness.

Authors:  P M Kiely; L G Carney; G Smith
Journal:  Am J Optom Physiol Opt       Date:  1982-12

6.  Overnight swelling of the living human cornea.

Authors:  G W Mertz
Journal:  J Am Optom Assoc       Date:  1980-03

7.  Thinning of the human cornea on awakening.

Authors:  R B Mandell; I Fatt
Journal:  Nature       Date:  1965-10-16       Impact factor: 49.962

8.  Corneal response to rigid and hydrogel lenses during eye closure.

Authors:  M R O'Neal; K A Polse; M D Sarver
Journal:  Invest Ophthalmol Vis Sci       Date:  1984-07       Impact factor: 4.799

9.  Ocular rigidity and intraocular pressure in keratoconus.

Authors:  A M Brooks; I F Robertson; A M Mahoney
Journal:  Aust J Ophthalmol       Date:  1984-11

10.  Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses.

Authors:  B A Holden; G W Mertz
Journal:  Invest Ophthalmol Vis Sci       Date:  1984-10       Impact factor: 4.799

View more
  2 in total

1.  Effects of aging on corneal biomechanical properties and their impact on 24-hour measurement of intraocular pressure.

Authors:  Teruyo Kida; John H K Liu; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2008-07-09       Impact factor: 5.258

2.  The effect of contact lens-induced corneal edema on Goldmann applanation tonometry and dynamic contour tonometry.

Authors:  Jong-Hyun Oh; Chungkwon Yoo; Yong Yeon Kim; Hyo-Myung Kim; Jong-Suk Song
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-09       Impact factor: 3.117

  2 in total