BACKGROUND: The measurement of hemoglobin concentration ([Hb]) is performed routinely as a part of a complete blood cell count to evaluate the oxygen-carrying capacity of blood. Devices currently available to physicians and clinical laboratories for measuring [Hb] are accurate, operate on small samples, and provide results rapidly, but may be prohibitively expensive for resource-limited settings. The unavailability of accurate but inexpensive diagnostic tools often precludes proper diagnosis of anemia in low-income developing countries. Therefore, we developed a simple paper-based assay for measuring [Hb]. METHODS: A 20-μL droplet of a mixture of blood and Drabkin reagent was deposited onto patterned chromatography paper. The resulting blood stain was digitized with a portable scanner and analyzed. The mean color intensity of the blood stain was used to quantify [Hb]. We compared the performance of the paper-based Hb assay with a hematology analyzer (comparison method) using blood samples from 54 subjects. RESULTS: The values of [Hb] measured by the paper-based assay and the comparison method were highly correlated (R(2) = 0.9598); the standard deviation of the difference between the two measurements was 0.62 g/dL. The assay was accurate within 1 g/dL 90.7% of the time, overestimating [Hb] by ≥1 g/dL in 1.9% and underestimating [Hb] by ≥1 g/dL in 7.4% of the subjects. CONCLUSIONS: This study demonstrates the feasibility of the paper-based Hb assay. This simple, low-cost test should be useful for diagnosing anemia in resource-limited settings, particularly in the context of care for malaria, HIV, and sickle cell disease patients in sub-Saharan Africa.
BACKGROUND: The measurement of hemoglobin concentration ([Hb]) is performed routinely as a part of a complete blood cell count to evaluate the oxygen-carrying capacity of blood. Devices currently available to physicians and clinical laboratories for measuring [Hb] are accurate, operate on small samples, and provide results rapidly, but may be prohibitively expensive for resource-limited settings. The unavailability of accurate but inexpensive diagnostic tools often precludes proper diagnosis of anemia in low-income developing countries. Therefore, we developed a simple paper-based assay for measuring [Hb]. METHODS:A 20-μL droplet of a mixture of blood and Drabkin reagent was deposited onto patterned chromatography paper. The resulting blood stain was digitized with a portable scanner and analyzed. The mean color intensity of the blood stain was used to quantify [Hb]. We compared the performance of the paper-based Hb assay with a hematology analyzer (comparison method) using blood samples from 54 subjects. RESULTS: The values of [Hb] measured by the paper-based assay and the comparison method were highly correlated (R(2) = 0.9598); the standard deviation of the difference between the two measurements was 0.62 g/dL. The assay was accurate within 1 g/dL 90.7% of the time, overestimating [Hb] by ≥1 g/dL in 1.9% and underestimating [Hb] by ≥1 g/dL in 7.4% of the subjects. CONCLUSIONS: This study demonstrates the feasibility of the paper-based Hb assay. This simple, low-cost test should be useful for diagnosing anemia in resource-limited settings, particularly in the context of care for malaria, HIV, and sickle cell diseasepatients in sub-Saharan Africa.
Authors: Llorenç Quintó; John J Aponte; Clara Menéndez; Jahit Sacarlal; Pedro Aide; Mateu Espasa; Inacio Mandomando; Caterina Guinovart; Eusebio Macete; Rosmarie Hirt; Honorathy Urassa; Margarita M Navia; Ricardo Thompson; Pedro L Alonso Journal: Trop Med Int Health Date: 2006-08 Impact factor: 2.622
Authors: H Gehring; C Hornberger; L Dibbelt; A Rothsigkeit; K Gerlach; J Schumacher; P Schmucker Journal: Acta Anaesthesiol Scand Date: 2002-09 Impact factor: 2.105
Authors: Patrick T McGann; Erika A Tyburski; Vysolela de Oliveira; Brigida Santos; Russell E Ware; Wilbur A Lam Journal: Am J Hematol Date: 2015-10-12 Impact factor: 10.047
Authors: Yunus Alapan; Arwa Fraiwan; Erdem Kucukal; M Noman Hasan; Ryan Ung; Myeongseop Kim; Isaac Odame; Jane A Little; Umut A Gurkan Journal: Expert Rev Med Devices Date: 2016-11-22 Impact factor: 3.166
Authors: Catherine E Majors; Chelsey A Smith; Mary E Natoli; Kathryn A Kundrod; Rebecca Richards-Kortum Journal: Lab Chip Date: 2017-10-11 Impact factor: 6.799