Literature DB >> 15061388

Evaluation of the blood gas analyzer Gem PREMIER 3000.

Bénédicte Bénéteau-Burnat1, Marie-Chantal Bocque, Anne Lorin, Catherine Martin, Michel Vaubourdolle.   

Abstract

During the past few decades, new technologies have allowed the fabrication of miniaturized sensors and the development of analyzers well designed for point-of-care testing (POCT). They combined the ease-of-use and portability required for POC with the accuracy and the reliability of traditional systems. Instrumentation Laboratory introduced the GEM Premier 3000, a compact and portable system to rapidly analyze pH, pCO2, PO2, Ca2+, Na2+, K+, lactate, glucose and hematocrit, from 135 microl of whole blood with a simple component: a cartridge, the GEM Premier Pak. The analytical performance was compared with the Radiometer ABL 725 instrument for blood gas/ electrolytes/metabolites, and for hematocrit with the centrifuged microhematocrit method. Aqueous quality control materials (Instrumentation Laboratory) were used for precision and recovery studies. The evaluation was performed according to the Valtec protocol, designed by the French Society of Clinical Biology, for imprecision, linearity and accuracy. With-in-run and between-run imprecisions for all the parameters gave good CV values. Linearity was good and results comparison showed close agreement with correlation coefficients between 0.91 and 0.99. The analyzer is very easy to use; the simplicity and the convenience of only one consumable make the GEM Premier 3000 very suitable for a STAT laboratory or for POCT.

Entities:  

Mesh:

Year:  2004        PMID: 15061388     DOI: 10.1515/CCLM.2004.018

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  9 in total

Review 1.  Recent Developments in Magnetic Diagnostic Systems.

Authors:  Hakho Lee; Tae-Hyun Shin; Jinwoo Cheon; Ralph Weissleder
Journal:  Chem Rev       Date:  2015-08-10       Impact factor: 60.622

2.  Conductivity-based hematocrit measurement during cardiopulmonary bypass.

Authors:  Jacoline Steinfelder-Visscher; Patrick W Weerwind; Steven Teerenstra; Gheorghe A M Pop; René M H J Brouwer
Journal:  J Clin Monit Comput       Date:  2006-11-04       Impact factor: 2.502

3.  Hemoglobin test result variability and cost analysis of eight different analyzers during open heart surgery.

Authors:  Kirti P Patel; Gary W Hay; Mahesh Keitheri Cheteri; David W Holt
Journal:  J Extra Corpor Technol       Date:  2007-03

4.  Evaluation of point-of-care analyzers' ability to reduce bias in conductivity-based hematocrit measurement during cardiopulmonary bypass.

Authors:  Steven Teerenstra; Jacoline Steinfelder-Visscher; Jacqueline Klein Gunnewiek; Patrick W Weerwind
Journal:  J Clin Monit Comput       Date:  2013-08-30       Impact factor: 2.502

Review 5.  Blood glucose measurement in the intensive care unit: what is the best method?

Authors:  Huong T Le; Neil S Harris; Abby J Estilong; Arvid Olson; Mark J Rice
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

6.  Acute effects of an alternative electronic-control-device waveform in swine.

Authors:  James Jauchem; Charles W Beason; Michael C Cook
Journal:  Forensic Sci Med Pathol       Date:  2009-03-28       Impact factor: 2.007

7.  Blood gas measurements using the Bayer Rapid Point 405: are we basing our decisions on accurate data?

Authors:  Frederic Sarrazin; Michael J Tessler; Kenneth Kardash; Elizabeth McNamara; Christina Holcroft
Journal:  J Clin Monit Comput       Date:  2007-06-27       Impact factor: 1.977

8.  Repeatability of blood gas parameters, PCO2 gap, and PCO2 gap to arterial-to-venous oxygen content difference in critically ill adult patients.

Authors:  Jihad Mallat; Ali Lazkani; Malcolm Lemyze; Florent Pepy; Mehdi Meddour; Gaëlle Gasan; Johanna Temime; Nicolas Vangrunderbeeck; Laurent Tronchon; Didier Thevenin
Journal:  Medicine (Baltimore)       Date:  2015-01       Impact factor: 1.889

9.  Comparison the Effect of Active Cyclic Breathing Technique and Routine Chest Physiotherapy on Pain and Respiratory Parameters After Coronary Artery Graft Surgery: A Randomized Clinical Trial.

Authors:  Ahmad Salehi Derakhtanjani; Ali Ansari Jaberi; Shahin Haydari; Tayebeh Negahban Bonabi
Journal:  Anesth Pain Med       Date:  2019-10-16
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.