Literature DB >> 17482005

Residual motor signal in long-term human severed peripheral nerves and feasibility of neural signal-controlled artificial limb.

Xiaofeng Jia1, Matthew A Koenig, Xiaowen Zhang, Jian Zhang, Tongyi Chen, Zhongwei Chen.   

Abstract

PURPOSE: The residual motor pathways after amputation have not been fully elucidated. We sampled potentials from peripheral nerve stumps with intrafascicular electrodes to study residual motor transmission and explore the feasibility of nerve signal-controlled artificial limbs.
METHODS: Six intrafascicular electrodes were inserted into the ulnar, radial, and median nerves in the stump of an amputee. An electrode was placed outside the fascicle as a reference. Potentials from 4 of the 6 electrodes per trial were monitored using a 4-channel electromyogram machine, and 32 groups of electrophysiologic tests were conducted under volitional control. Actions included finger extension and flexion, forearm pronation and supination, and wrist extension and flexion. Each action was carried out with light, intermediate, and full efforts. Then, 2 of 6 electrodes randomly chosen per trial were interfaced to a nerve signal-controlled artificial limb. Finger extension and flexion of the prosthesis were tested under volitional control.
RESULTS: The volitional motor nerve potentials uniquely associated with the missing limb were recorded successfully with intrafascicular electrodes. The signal amplitude from the radial nerve was 5.5 microV +/- 0.8 (mean +/- SD), which was greater than the amplitudes from the ulnar (2.5 microV +/- 0.4) and median (2.2 microV +/- 0.3) nerves. Under volitional control of the subject, finger extension of the artificial limb was triggered by the radial nerve signal, but the remaining actions were unsuccessful.
CONCLUSIONS: The long-term amputee was able to generate motor neuron activity related to phantom limb movement. Intrafascicular electrodes can be used to monitor residual motor nerve activity in the stump, and the amplitude may predict successful control of artificial limbs.

Entities:  

Mesh:

Year:  2007        PMID: 17482005     DOI: 10.1016/j.jhsa.2007.02.021

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  20 in total

1.  Noise and selectivity of velocity-selective multi-electrode nerve cuffs.

Authors:  N Donaldson; R Rieger; M Schuettler; J Taylor
Journal:  Med Biol Eng Comput       Date:  2008-08-12       Impact factor: 2.602

2.  Dexterous control of a prosthetic hand using fine-wire intramuscular electrodes in targeted extrinsic muscles.

Authors:  Christian Cipriani; Jacob L Segil; J Alex Birdwell; Richard F ff Weir
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2014-01-21       Impact factor: 3.802

3.  Rodent model for assessing the long term safety and performance of peripheral nerve recording electrodes.

Authors:  Srikanth Vasudevan; Kunal Patel; Cristin Welle
Journal:  J Neural Eng       Date:  2016-12-09       Impact factor: 5.379

4.  Targeted Muscle Reinnervation for the Upper and Lower Extremity.

Authors:  Todd A Kuiken; Ann K Barlow; Levi Hargrove; Gregorgy A Dumanian
Journal:  Tech Orthop       Date:  2017-06

5.  Optimal electrical stimulation boosts stem cell therapy in nerve regeneration.

Authors:  Jian Du; Gehua Zhen; Huanwen Chen; Shuming Zhang; Liming Qing; Xiuli Yang; Gabsang Lee; Hai-Quan Mao; Xiaofeng Jia
Journal:  Biomaterials       Date:  2018-07-20       Impact factor: 12.479

6.  Recording of electric signal passing through a pylon in direct skeletal attachment of leg prostheses with neuromuscular control.

Authors:  M Pitkin; C Cassidy; R Muppavarapu; D Edell
Journal:  IEEE Trans Biomed Eng       Date:  2012-02-13       Impact factor: 4.538

7.  Microscale electrode implantation during nerve repair: effects on nerve morphology, electromyography, and recovery of muscle contractile function.

Authors:  Melanie G Urbanchek; Benjamin Wei; Brent M Egeland; Mohammad R Abidian; Daryl R Kipke; Paul S Cederna
Journal:  Plast Reconstr Surg       Date:  2011-10       Impact factor: 4.730

8.  Regenerative Engineering and Bionic Limbs.

Authors:  Roshan James; Cato T Laurencin
Journal:  Rare Metals       Date:  2015-03-01       Impact factor: 4.003

Review 9.  Implantable neurotechnologies: a review of integrated circuit neural amplifiers.

Authors:  Kian Ann Ng; Elliot Greenwald; Yong Ping Xu; Nitish V Thakor
Journal:  Med Biol Eng Comput       Date:  2016-01-22       Impact factor: 2.602

Review 10.  Design features of implants for direct skeletal attachment of limb prostheses.

Authors:  M Pitkin
Journal:  J Biomed Mater Res A       Date:  2013-04-02       Impact factor: 4.396