Literature DB >> 18696136

Noise and selectivity of velocity-selective multi-electrode nerve cuffs.

N Donaldson1, R Rieger, M Schuettler, J Taylor.   

Abstract

Using a multi-electrode nerve-signal recording cuff and a method of signal processing described previously, activity in axons with different propagation velocities can be distinguished, and the relative amplitude of the small-fibre signals increased. This paper is, largely, an analysis of the selectivity and noise of this system though impedance measurements from an actual cuff are included. The signal processor includes narrow band-pass filters. It is shown that the selectivity and noise both increase with the centre frequencies of these filters. A convenient approach is to make the filter frequencies inversely related to the artificial time delays so that the filter 'Q's are approximately constant and the noise densities are equal for all velocity filters. Numerical calculations, using formulae for this system and for the conventional tripole, based on a fixed cuff size and tissue resistivity, find the number of action potentials per second that must pass through the cuff so that the signal power equals the noise power. For slow fibres (20 m/s), the rate is 14 times lower for the multi-electrode cuff than the tripole, a significant advantage for recording from these fibres.

Entities:  

Mesh:

Year:  2008        PMID: 18696136     DOI: 10.1007/s11517-008-0365-4

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  14 in total

1.  Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording.

Authors:  J Taylor; N Donaldson; J Winter
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

2.  Very low-noise ENG amplifier system using CMOS technology.

Authors:  Robert Rieger; Martin Schuettler; Dipankar Pal; Chris Clarke; Peter Langlois; John Taylor; Nick Donaldson
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2006-12       Impact factor: 3.802

3.  Model-based evaluation of the short-circuited tripolar cuff configuration.

Authors:  Lotte N S Andreasen; Johannes J Struijk
Journal:  Med Biol Eng Comput       Date:  2006-04-26       Impact factor: 2.602

4.  Velocity-selective recording from frog nerve using a multi-contact cuff electrode.

Authors:  Martin Schuettler; Vipin Seetohul; John Taylor; Nick Donaldson
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

5.  Residual motor signal in long-term human severed peripheral nerves and feasibility of neural signal-controlled artificial limb.

Authors:  Xiaofeng Jia; Matthew A Koenig; Xiaowen Zhang; Jian Zhang; Tongyi Chen; Zhongwei Chen
Journal:  J Hand Surg Am       Date:  2007 May-Jun       Impact factor: 2.230

6.  Technical note. Estimated electrode operating conditions of the first London Mk V implanted stimulator.

Authors:  P E Donaldson; N de N Donaldson; D N Rushton; T A Perkins
Journal:  J Med Eng Technol       Date:  1998 Sep-Oct

7.  The extracellular potential of a myelinated nerve fiber in an unbounded medium and in nerve cuff models.

Authors:  J J Struijk
Journal:  Biophys J       Date:  1997-06       Impact factor: 4.033

8.  Electrical properties of implant encapsulation tissue.

Authors:  W M Grill; J T Mortimer
Journal:  Ann Biomed Eng       Date:  1994 Jan-Feb       Impact factor: 3.934

Review 9.  A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems.

Authors:  Xavier Navarro; Thilo B Krueger; Natalia Lago; Silvestro Micera; Thomas Stieglitz; Paolo Dario
Journal:  J Peripher Nerv Syst       Date:  2005-09       Impact factor: 3.494

10.  Platinum electrode noise in the ENG spectrum.

Authors:  Xiao Liu; Andreas Demosthenous; Nick Donaldson
Journal:  Med Biol Eng Comput       Date:  2008-09-06       Impact factor: 2.602

View more
  6 in total

1.  The theory of velocity selective neural recording: a study based on simulation.

Authors:  John Taylor; Martin Schuettler; Chris Clarke; Nick Donaldson
Journal:  Med Biol Eng Comput       Date:  2012-02-24       Impact factor: 2.602

Review 2.  Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces.

Authors:  Stéphanie P Lacour; Samia Benmerah; Edward Tarte; James FitzGerald; Jordi Serra; Stephen McMahon; James Fawcett; Oliver Graudejus; Zhe Yu; Barclay Morrison
Journal:  Med Biol Eng Comput       Date:  2010-06-10       Impact factor: 2.602

3.  The Design of a Low Noise, Multi-Channel Recording System for Use in Implanted Peripheral Nerve Interfaces.

Authors:  Shamin Sadrafshari; Benjamin Metcalfe; Nick Donaldson; Nicolas Granger; Jon Prager; John Taylor
Journal:  Sensors (Basel)       Date:  2022-04-30       Impact factor: 3.847

4.  Effect on signal-to-noise ratio of splitting the continuous contacts of cuff electrodes into smaller recording areas.

Authors:  Max Ortiz-Catalan; Jorge Marin-Millan; Jean Delbeke; Bo Håkansson; Rickard Brånemark
Journal:  J Neuroeng Rehabil       Date:  2013-02-21       Impact factor: 4.262

5.  The Use of the Velocity Selective Recording Technique to Reveal the Excitation Properties of the Ulnar Nerve in Pigs.

Authors:  Felipe Rettore Andreis; Benjamin Metcalfe; Taha Al Muhammadee Janjua; Winnie Jensen; Suzan Meijs; Thomas Gomes Nørgaard Dos Santos Nielsen
Journal:  Sensors (Basel)       Date:  2021-12-23       Impact factor: 3.576

6.  A microfabricated nerve-on-a-chip platform for rapid assessment of neural conduction in explanted peripheral nerve fibers.

Authors:  Sandra Gribi; Sophie du Bois de Dunilac; Diego Ghezzi; Stéphanie P Lacour
Journal:  Nat Commun       Date:  2018-10-23       Impact factor: 14.919

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.