Literature DB >> 17468565

Functional hemodynamic monitoring.

Mehrnaz Hadian1, Michael R Pinsky.   

Abstract

PURPOSE OF REVIEW: To assess the recent literature on effective use of information received from hemodynamic monitoring. RECENT
FINDINGS: Dynamic hemodynamic measures are more effective in assessing cardiovascular status than static measures. In this review, we will focus on the application of hemodynamic monitoring to evaluate the effect of therapy.
SUMMARY: A systematic approach to an effective resuscitation effort can be incorporated into a protocolized cardiovascular management algorithm, which, in turn, can improve patient-centered outcomes and the cost of healthcare systems, by faster and more effective response in order to diagnose and treat hemodynamically unstable patients both inside and outside of intensive care units.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17468565     DOI: 10.1097/MCC.0b013e32811e14dd

Source DB:  PubMed          Journal:  Curr Opin Crit Care        ISSN: 1070-5295            Impact factor:   3.687


  11 in total

Review 1.  Pulse pressure variation: where are we today?

Authors:  Maxime Cannesson; Mateo Aboy; Christoph K Hofer; Mohamed Rehman
Journal:  J Clin Monit Comput       Date:  2011-02       Impact factor: 2.502

2.  A randomized trial of goal directed vs. standard fluid therapy in cytoreductive surgery with hyperthermic intraperitoneal chemotherapy.

Authors:  Luca Colantonio; Claudia Claroni; Luana Fabrizi; Maria Elena Marcelli; Maria Sofra; Diana Giannarelli; Alfredo Garofalo; Ester Forastiere
Journal:  J Gastrointest Surg       Date:  2015-01-17       Impact factor: 3.452

3.  A modified breathing pattern improves the performance of a continuous capnodynamic method for estimation of effective pulmonary blood flow.

Authors:  Caroline Hällsjö Sander; Thorir Sigmundsson; Magnus Hallbäck; Fernando Suarez Sipmann; Mats Wallin; Anders Oldner; Håkan Björne
Journal:  J Clin Monit Comput       Date:  2016-06-01       Impact factor: 2.502

4.  Quantitative assessment of cardiac load-responsiveness during extracorporeal life support: case and rationale.

Authors:  Antoine P Simons; Marcus D Lancé; Koen D Reesink; Frederik H van der Veen; Patrick W Weerwind; Jos G Maessen
Journal:  J Cardiothorac Surg       Date:  2010-04-27       Impact factor: 1.637

Review 5.  Functional haemodynamic monitoring.

Authors:  Michael R Pinsky
Journal:  Curr Opin Crit Care       Date:  2014-06       Impact factor: 3.687

6.  Stroke volume variation and serum creatinine changes during abdominal aortic aneurysm surgery: a time-integrated analysis.

Authors:  Paolo Lentini; Luca Zanoli; Pasquale Fatuzzo; Faeq Husain-Syed; Rudi Stramanà; Diego Cognolato; Vincenzo Catena; Marco Baiocchi; Antonio Granata; Roberto Dell'Aquila
Journal:  J Nephrol       Date:  2018-01-17       Impact factor: 3.902

7.  Volume assessment in mechanically ventilated critical care patients using bioimpedance vectorial analysis, brain natriuretic Peptide, and central venous pressure.

Authors:  Andrew A House; Mikko Haapio; Paolo Lentini; Ilona Bobek; Massimo de Cal; Dinna N Cruz; Grazia M Virzì; Rizzieri Carraro; Giampiero Gallo; Pasquale Piccinni; Claudio Ronco
Journal:  Int J Nephrol       Date:  2010-12-02

8.  Sigh maneuver to enhance assessment of fluid responsiveness during pressure support ventilation.

Authors:  Antonio Messina; Davide Colombo; Federico Lorenzo Barra; Gianmaria Cammarota; Giacomo De Mattei; Federico Longhini; Stefano Romagnoli; Francesco DellaCorte; Daniel De Backer; Maurizio Cecconi; Paolo Navalesi
Journal:  Crit Care       Date:  2019-01-28       Impact factor: 9.097

Review 9.  Pulmonary artery catheters for adult patients in intensive care.

Authors:  Sujanthy S Rajaram; Nayan K Desai; Ankur Kalra; Mithil Gajera; Susan K Cavanaugh; William Brampton; Duncan Young; Sheila Harvey; Kathy Rowan
Journal:  Cochrane Database Syst Rev       Date:  2013-02-28

Review 10.  Clinical review: Does it matter which hemodynamic monitoring system is used?

Authors:  Davinder Ramsingh; Brenton Alexander; Maxime Cannesson
Journal:  Crit Care       Date:  2013-03-05       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.