Literature DB >> 28943696

Automated 3D coronary sinus catheter detection using a scanning-beam digital x-ray system.

David A P Dunkerley1, Jordan M Slagowski1, Lindsay E Bodart1, Michael A Speidel1,2.   

Abstract

Scanning-beam digital x-ray (SBDX) is an inverse geometry x-ray fluoroscopy system capable of tomosynthesis-based 3D tracking of catheter electrodes concurrent with fluoroscopic display. To facilitate respiratory motion-compensated 3D catheter tracking, an automated coronary sinus (CS) catheter detection algorithm for SBDX was developed. The technique uses the 3D localization capability of SBDX and prior knowledge of the catheter shape. Candidate groups of points representing the CS catheter are obtained from a 3D shape-constrained search. A cost function is then minimized over the groups to select the most probable CS catheter candidate. The algorithm was implemented in MATLAB and tested offline using recorded image sequences of a chest phantom containing a CS catheter, ablation catheter, and fiducial clutter. Fiducial placement was varied to create challenging detection scenarios. Table panning and elevation was used to simulate motion. The CS catheter detection method had 98.1% true positive rate and 100% true negative rate in 2755 frames of imaging. Average processing time was 12.7 ms/frame on a PC with a 3.4 GHz CPU and 8 GB memory. Motion compensation based on 3D CS catheter tracking was demonstrated in a moving chest phantom with a fixed CS catheter and an ablation catheter pulled along a fixed trajectory. The RMS error in the tracked ablation catheter trajectory was 1.41 mm, versus 10.35 mm without motion compensation. A computationally efficient method of automated 3D CS catheter detection has been developed to assist with motion-compensated 3D catheter tracking and registration of 3D cardiac models to tracked catheters.

Entities:  

Keywords:  X-ray fluoroscopy; catheter tracking; coronary sinus; inverse geometry; scanning-beam digital x-ray

Year:  2017        PMID: 28943696      PMCID: PMC5606249          DOI: 10.1117/12.2254443

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  9 in total

1.  Respiratory motion of the heart from free breathing coronary angiograms.

Authors:  Guy Shechter; Cengizhan Ozturk; Jon R Resar; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2004-08       Impact factor: 10.048

2.  Catheter motion during atrial ablation due to the beating heart and respiration: impact on accuracy and spatial referencing in three-dimensional mapping.

Authors:  Hanno U Klemm; Daniel Steven; Christin Johnsen; Rodolfo Ventura; Thomas Rostock; Boris Lutomsky; Tim Risius; Thomas Meinertz; Stephan Willems
Journal:  Heart Rhythm       Date:  2007-01-18       Impact factor: 6.343

3.  Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions.

Authors:  YingLiang Ma; Nicolas Gogin; Pascal Cathier; R James Housden; Geert Gijsbers; Michael Cooklin; Mark O'Neill; Jaswinder Gill; C Aldo Rinaldi; Reza Razavi; Kawal S Rhode
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

4.  Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system.

Authors:  Michael A Speidel; Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

5.  Analysis of Left Atrial Respiratory and Cardiac Motion for Cardiac Ablation Therapy.

Authors:  M E Rettmann; D R Holmes; S B Johnson; H I Lehmann; R A Robb; D L Packer
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02-21

6.  Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia.

Authors:  Sébastien Knecht; Hicham Skali; Mark D O'Neill; Matthew Wright; Seiichiro Matsuo; Ghulam Muqtada Chaudhry; Charles I Haffajee; Isabelle Nault; Geert H M Gijsbers; Frederic Sacher; Francois Laurent; Michel Montaudon; Olivier Corneloup; Mélèze Hocini; Michel Haïssaguerre; Michael V Orlov; Pierre Jaïs
Journal:  Europace       Date:  2008-05-28       Impact factor: 5.214

7.  Detector, collimator and real-time reconstructor for a new scanning-beam digital x-ray (SBDX) prototype.

Authors:  Michael A Speidel; Michael T Tomkowiak; Amish N Raval; David A P Dunkerley; Jordan M Slagowski; Paul Kahn; Jamie Ku; Tobias Funk
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015

8.  Changes in left atrial anatomy due to respiration: impact on three-dimensional image integration during atrial fibrillation ablation.

Authors:  Joris Ector; Stijn De Buck; Dirk Loeckx; Walter Coudyzer; Frederik Maes; Steven Dymarkowski; Jan Bogaert; Hein Heidbüchel
Journal:  J Cardiovasc Electrophysiol       Date:  2008-03-26

9.  Clinical evaluation of respiratory motion compensation for anatomical roadmap guided cardiac electrophysiology procedures.

Authors:  YingLiang Ma; Andy P King; Nicolas Gogin; Geert Gijsbers; C A Rinaldi; Jaswinder Gill; Reza Razavi; Kawal S Rhode
Journal:  IEEE Trans Biomed Eng       Date:  2011-09-15       Impact factor: 4.538

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.