Literature DB >> 17449766

Multiprojection correlation imaging for improved detection of pulmonary nodules.

Ehsan Samei1, Stanton A Stebbins, James T Dobbins, H Page McAdams, Joseph Y Lo.   

Abstract

OBJECTIVE: The purpose of this study was the development and preliminary evaluation of multiprojection correlation imaging with 3D computer-aided detection (CAD) on chest radiographs for cost- and dose-effective improvement of early detection of pulmonary nodules. SUBJECTS AND METHODS: Digital chest radiographs of 10 configurations of a chest phantom and of seven human subjects were acquired in multiple angular projections with an acquisition time of 11 seconds (single breath-hold) and total exposure comparable with that of a posteroanterior chest radiograph. An initial 2D CAD algorithm with two difference-of-gaussians filters and multilevel thresholds was developed with an independent database of 44 single-view chest radiographs with confirmed lesions. This 2D CAD algorithm was used on each projection image to find likely suspect nodules. The CAD outputs were reconstructed in 3D, reinforcing signals associated with true nodules while simultaneously decreasing false-positive findings produced by overlapping anatomic features. The performance of correlation imaging was tested on two to 15 projection images.
RESULTS: Optimum performance of correlation imaging was attained when nine projection images were used. Compared with conventional, single-view CAD, correlation imaging decreased as much as 79% the frequency of false-positive findings in phantom cases at a sensitivity level of 65%. The corresponding reduction in false-positive findings in the cases of human subjects was 78%.
CONCLUSION: Although limited by a relatively simple CAD implementation and a small number of cases, the findings suggest that correlation imaging performs substantially better than single-view CAD and may greatly enhance identification of subtle solitary pulmonary nodules on chest radiographs.

Entities:  

Mesh:

Year:  2007        PMID: 17449766     DOI: 10.2214/AJR.06.0843

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  9 in total

1.  A computerized scheme for lung nodule detection in multiprojection chest radiography.

Authors:  Wei Guo; Qiang Li; Sarah J Boyce; H Page McAdams; Junji Shiraishi; Kunio Doi; Ehsan Samei
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Preliminary evaluation of biplane correlation (BCI) stereographic imaging for lung nodule detection.

Authors:  Sarah J Boyce; H Page McAdams; Carl E Ravin; Edward F Patz; Lacey Washington; Santiago Martinez; Lynne Koweek; Ehsan Samei
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

3.  Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach.

Authors:  Swatee Singh; Georgia D Tourassi; Jay A Baker; Ehsan Samei; Joseph Y Lo
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

4.  Biplane correlation imaging: a feasibility study based on phantom and human data.

Authors:  Ehsan Samei; Nariman Majdi-Nasab; James T Dobbins; H Page McAdams
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

5.  Design and Development of a New Multi-Projection X-Ray System for Chest Imaging.

Authors:  Amarpreet S Chawla; Sarah Boyce; Lacey Washington; H Page McAdams; Ehsan Samei
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-10       Impact factor: 1.679

6.  True detection versus "accidental" detection of small lung cancer by a computer-aided detection (CAD) program on chest radiographs.

Authors:  Feng Li; Roger Engelmann; Kunio Doi; Heber Macmahon
Journal:  J Digit Imaging       Date:  2009-05-07       Impact factor: 4.056

7.  Towards optimized acquisition scheme for multiprojection correlation imaging of breast cancer.

Authors:  Amarpreet S Chawla; Robert S Saunders; Swatee Singh; Joseph Y Lo; Ehsan Samei
Journal:  Acad Radiol       Date:  2009-04       Impact factor: 3.173

8.  A mathematical model platform for optimizing a multiprojection breast imaging system.

Authors:  Amarpreet S Chawla; Ehsan Samei; Robert S Saunders; Joseph Y Lo; Jay A Baker
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

Review 9.  Imaging and cancer: a review.

Authors:  Leonard Fass
Journal:  Mol Oncol       Date:  2008-05-10       Impact factor: 7.449

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.